Cargando…

PVC Membrane Sensors for Potentiometric Determination of Acebutolol

The construction and general performance characteristics of two novel potentiometric membrane sensors responsive to the acebutolol are described. The sensors are based on the use of ion-association complexes of acebutolol (AC) with tetraphenylborate(TPB) (I) and phosphomolybdate(PM) (II) as exchange...

Descripción completa

Detalles Bibliográficos
Autores principales: Mostafa, Gamal Abdel-Hafiz, Hefnawy, Mohamed Mahmoud, Al-Majed, Abdulrahman
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3841894/
https://www.ncbi.nlm.nih.gov/pubmed/28903293
_version_ 1782292860315369472
author Mostafa, Gamal Abdel-Hafiz
Hefnawy, Mohamed Mahmoud
Al-Majed, Abdulrahman
author_facet Mostafa, Gamal Abdel-Hafiz
Hefnawy, Mohamed Mahmoud
Al-Majed, Abdulrahman
author_sort Mostafa, Gamal Abdel-Hafiz
collection PubMed
description The construction and general performance characteristics of two novel potentiometric membrane sensors responsive to the acebutolol are described. The sensors are based on the use of ion-association complexes of acebutolol (AC) with tetraphenylborate(TPB) (I) and phosphomolybdate(PM) (II) as exchange sites in a PVC matrix. The sensors show a fast, stable and near- Nernstian for the mono charge cation of AC over the concentration range 1×10(-3) - ∼10(-6) M at 25 °C over the pH range 2.0 - 6.0 with cationic slope of 51.5 ± 0.5 and 53.0 ± 0.5 per concentration decade for AC-I and AC-II sensors respectively. The lower detection limit is 6×10(-6) M and 4×0(-6) M with the response time 20-30 s in the same order of both sensors. Selectivity coefficients of AC related to a number of interfering cation and some organic compounds were investigated. There are negligible interferences are caused by most of the investigated species. The direct determination of 3 - 370 μg/ml of AC shows an average recovery of 99.4 and 99.5% and a mean relative standard deviation of 1.5% at 100.0 μg/ml for sensor I and II respectively. The results obtained by determination of AC in tablets using the proposed sensors which comparable favorably with those obtained by the British pharmacopoeia method. In the present investigation the electrodes have been utilized as end point indicator for some precipitation titration reactions.
format Online
Article
Text
id pubmed-3841894
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-38418942013-11-29 PVC Membrane Sensors for Potentiometric Determination of Acebutolol Mostafa, Gamal Abdel-Hafiz Hefnawy, Mohamed Mahmoud Al-Majed, Abdulrahman Sensors (Basel) Full Research Paper The construction and general performance characteristics of two novel potentiometric membrane sensors responsive to the acebutolol are described. The sensors are based on the use of ion-association complexes of acebutolol (AC) with tetraphenylborate(TPB) (I) and phosphomolybdate(PM) (II) as exchange sites in a PVC matrix. The sensors show a fast, stable and near- Nernstian for the mono charge cation of AC over the concentration range 1×10(-3) - ∼10(-6) M at 25 °C over the pH range 2.0 - 6.0 with cationic slope of 51.5 ± 0.5 and 53.0 ± 0.5 per concentration decade for AC-I and AC-II sensors respectively. The lower detection limit is 6×10(-6) M and 4×0(-6) M with the response time 20-30 s in the same order of both sensors. Selectivity coefficients of AC related to a number of interfering cation and some organic compounds were investigated. There are negligible interferences are caused by most of the investigated species. The direct determination of 3 - 370 μg/ml of AC shows an average recovery of 99.4 and 99.5% and a mean relative standard deviation of 1.5% at 100.0 μg/ml for sensor I and II respectively. The results obtained by determination of AC in tablets using the proposed sensors which comparable favorably with those obtained by the British pharmacopoeia method. In the present investigation the electrodes have been utilized as end point indicator for some precipitation titration reactions. Molecular Diversity Preservation International (MDPI) 2007-12-13 /pmc/articles/PMC3841894/ /pubmed/28903293 Text en © 2007 by MDPI (http://www.mdpi.org). Reproduction is permitted for noncommercial purposes.
spellingShingle Full Research Paper
Mostafa, Gamal Abdel-Hafiz
Hefnawy, Mohamed Mahmoud
Al-Majed, Abdulrahman
PVC Membrane Sensors for Potentiometric Determination of Acebutolol
title PVC Membrane Sensors for Potentiometric Determination of Acebutolol
title_full PVC Membrane Sensors for Potentiometric Determination of Acebutolol
title_fullStr PVC Membrane Sensors for Potentiometric Determination of Acebutolol
title_full_unstemmed PVC Membrane Sensors for Potentiometric Determination of Acebutolol
title_short PVC Membrane Sensors for Potentiometric Determination of Acebutolol
title_sort pvc membrane sensors for potentiometric determination of acebutolol
topic Full Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3841894/
https://www.ncbi.nlm.nih.gov/pubmed/28903293
work_keys_str_mv AT mostafagamalabdelhafiz pvcmembranesensorsforpotentiometricdeterminationofacebutolol
AT hefnawymohamedmahmoud pvcmembranesensorsforpotentiometricdeterminationofacebutolol
AT almajedabdulrahman pvcmembranesensorsforpotentiometricdeterminationofacebutolol