Cargando…

The need to add motor evoked potential monitoring to somatosensory and electromyographic monitoring in cervical spine surgery

Intraoperative neural monitoring (IONM), utilizing somatosensory evoked potentials (SEP) and electromyography (EMG), was introduced to cervical spine surgery in the late 1980's. However, as SEP only provided physiological data regarding the posterior cord, new motor deficits were observed utili...

Descripción completa

Detalles Bibliográficos
Autor principal: Epstein, Nancy E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3842003/
https://www.ncbi.nlm.nih.gov/pubmed/24340237
http://dx.doi.org/10.4103/2152-7806.120782
_version_ 1782292878257553408
author Epstein, Nancy E.
author_facet Epstein, Nancy E.
author_sort Epstein, Nancy E.
collection PubMed
description Intraoperative neural monitoring (IONM), utilizing somatosensory evoked potentials (SEP) and electromyography (EMG), was introduced to cervical spine surgery in the late 1980's. However, as SEP only provided physiological data regarding the posterior cord, new motor deficits were observed utilizing SEP alone. This prompted the development of motor evoked potential monitoring (MEP) which facilitated real-time assessment of the anterior/anterolateral spinal cord. Although all three modalities, SEP, EMG, and MEP, are routinely available for IONM of cervical spine procedures, MEP are not yet routinely employed. The purpose of this review is to emphasize that MEP should now routinely accompany SEP and EMG when performing IONM of cervical spine surgery. Interestingly, one of the most common reasons for malpractice suits involving the cervical spine, is quadriparesis/quadriplegia following a single level anterior cervical diskectomy and fusion (ACDF). Previously, typical allegations in these suits included; negligent surgery, lack of informed consent, failure to diagnose/treat, and failure to brace. Added to this list, perhaps, as the 5(th) most reason for a suit will be failure to monitor with MEP. This review documents the value of MEP monitoring in addition to SEP and EMG monitoring in cervical spine surgery. The addition of MEP0 should minimize major motor injuries, and more accurately and reliably detect impending anterior cord deterioration that may be missed with SEP monitoring alone.
format Online
Article
Text
id pubmed-3842003
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-38420032013-12-11 The need to add motor evoked potential monitoring to somatosensory and electromyographic monitoring in cervical spine surgery Epstein, Nancy E. Surg Neurol Int Surgical Neurology International: Spine Intraoperative neural monitoring (IONM), utilizing somatosensory evoked potentials (SEP) and electromyography (EMG), was introduced to cervical spine surgery in the late 1980's. However, as SEP only provided physiological data regarding the posterior cord, new motor deficits were observed utilizing SEP alone. This prompted the development of motor evoked potential monitoring (MEP) which facilitated real-time assessment of the anterior/anterolateral spinal cord. Although all three modalities, SEP, EMG, and MEP, are routinely available for IONM of cervical spine procedures, MEP are not yet routinely employed. The purpose of this review is to emphasize that MEP should now routinely accompany SEP and EMG when performing IONM of cervical spine surgery. Interestingly, one of the most common reasons for malpractice suits involving the cervical spine, is quadriparesis/quadriplegia following a single level anterior cervical diskectomy and fusion (ACDF). Previously, typical allegations in these suits included; negligent surgery, lack of informed consent, failure to diagnose/treat, and failure to brace. Added to this list, perhaps, as the 5(th) most reason for a suit will be failure to monitor with MEP. This review documents the value of MEP monitoring in addition to SEP and EMG monitoring in cervical spine surgery. The addition of MEP0 should minimize major motor injuries, and more accurately and reliably detect impending anterior cord deterioration that may be missed with SEP monitoring alone. Medknow Publications & Media Pvt Ltd 2013-10-29 /pmc/articles/PMC3842003/ /pubmed/24340237 http://dx.doi.org/10.4103/2152-7806.120782 Text en Copyright: © 2013 Epstein NE. http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Surgical Neurology International: Spine
Epstein, Nancy E.
The need to add motor evoked potential monitoring to somatosensory and electromyographic monitoring in cervical spine surgery
title The need to add motor evoked potential monitoring to somatosensory and electromyographic monitoring in cervical spine surgery
title_full The need to add motor evoked potential monitoring to somatosensory and electromyographic monitoring in cervical spine surgery
title_fullStr The need to add motor evoked potential monitoring to somatosensory and electromyographic monitoring in cervical spine surgery
title_full_unstemmed The need to add motor evoked potential monitoring to somatosensory and electromyographic monitoring in cervical spine surgery
title_short The need to add motor evoked potential monitoring to somatosensory and electromyographic monitoring in cervical spine surgery
title_sort need to add motor evoked potential monitoring to somatosensory and electromyographic monitoring in cervical spine surgery
topic Surgical Neurology International: Spine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3842003/
https://www.ncbi.nlm.nih.gov/pubmed/24340237
http://dx.doi.org/10.4103/2152-7806.120782
work_keys_str_mv AT epsteinnancye theneedtoaddmotorevokedpotentialmonitoringtosomatosensoryandelectromyographicmonitoringincervicalspinesurgery
AT epsteinnancye needtoaddmotorevokedpotentialmonitoringtosomatosensoryandelectromyographicmonitoringincervicalspinesurgery