Cargando…

Hemodynamic Impact of Absent or Reverse End-Diastolic Flow in the Two Umbilical Arteries in Growth-Restricted Fetuses

OBJECTIVE: To determine if bilateral absent or reverse end-diastolic (ARED) flow in the two umbilical arteries (UAs) at the perivesical (PVC) segment represents a more severe degree of hemodynamic compromise than unilateral ARED flow at the PVC segment in singleton pregnancies complicated by intraut...

Descripción completa

Detalles Bibliográficos
Autores principales: Lecarpentier, Edouard, Cordier, Anne Gaëlle, Proulx, Francine, Fouron, Jean Claude, Gitz, Laurence, Grange, Gilles, Benachi, Alexandra, Tsatsaris, Vassilis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3842244/
https://www.ncbi.nlm.nih.gov/pubmed/24312271
http://dx.doi.org/10.1371/journal.pone.0081160
_version_ 1782292902721880064
author Lecarpentier, Edouard
Cordier, Anne Gaëlle
Proulx, Francine
Fouron, Jean Claude
Gitz, Laurence
Grange, Gilles
Benachi, Alexandra
Tsatsaris, Vassilis
author_facet Lecarpentier, Edouard
Cordier, Anne Gaëlle
Proulx, Francine
Fouron, Jean Claude
Gitz, Laurence
Grange, Gilles
Benachi, Alexandra
Tsatsaris, Vassilis
author_sort Lecarpentier, Edouard
collection PubMed
description OBJECTIVE: To determine if bilateral absent or reverse end-diastolic (ARED) flow in the two umbilical arteries (UAs) at the perivesical (PVC) segment represents a more severe degree of hemodynamic compromise than unilateral ARED flow at the PVC segment in singleton pregnancies complicated by intrauterine growth restriction (IUGR). METHODS: This was a prospective observational study. One hundred nine fetuses with IUGR underwent a total of 225 ultrasound (US) examinations. We measured the pulsatility index (PI) from the two UAs at the PVC segment, UA in the free floating cord (FFC), middle cerebral artery (MCA), ductus venosus (DV) and the aortic isthmus blood flow index (IFI). Three groups were classified according to bilateral positive end-diastolic (PED) flow, unilateral ARED flow or bilateral ARED flow in the UAs at the PVC segment. RESULTS: The proportions of US examinations with PED flow, unilateral ARED flow and bilateral ARED flow in the UAs were 54.7%, 20.4%, and 24.9%, respectively. At the last US examination, the IFI z-scores were significantly lower in the bilateral ARED group (-6.28±4.30) compared to the unilateral ARED group (-1.72±3.18, p<0.05) and the bilateral PED group (-0.83±2.36, p<0.05), the DV-PI z-scores were significantly higher in the bilateral ARED group (2.15±3.79) compared to the bilateral PED group (0.64±1.50, p<0.05). Before 32 weeks of gestation, the interval between US examination and delivery was significantly shorter in the bilateral ARED group (8.9 days ±8.2) than the unilateral ARED group (15.9 days ±13.4, p<0.05) and the bilateral PED group (30.3 days±25.7, p<0.05). CONCLUSION: There are significant differences in fetal blood fluxes between left and right UA. Doppler examination at the PVC segment significantly improves the comparability of UA-PI between two successive US examinations and allows a longitudinal and independent hemodynamic investigation of each UA. Examination of a single UA in free floating cord may miss a large fraction of unilateral ARED flow. In singleton IUGR fetuses, a bilateral ARED flow in the UAs at the PVC segment indicates more severe hemodynamic compromise and worse fetal conditions than unilateral ARED flow.
format Online
Article
Text
id pubmed-3842244
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-38422442013-12-05 Hemodynamic Impact of Absent or Reverse End-Diastolic Flow in the Two Umbilical Arteries in Growth-Restricted Fetuses Lecarpentier, Edouard Cordier, Anne Gaëlle Proulx, Francine Fouron, Jean Claude Gitz, Laurence Grange, Gilles Benachi, Alexandra Tsatsaris, Vassilis PLoS One Research Article OBJECTIVE: To determine if bilateral absent or reverse end-diastolic (ARED) flow in the two umbilical arteries (UAs) at the perivesical (PVC) segment represents a more severe degree of hemodynamic compromise than unilateral ARED flow at the PVC segment in singleton pregnancies complicated by intrauterine growth restriction (IUGR). METHODS: This was a prospective observational study. One hundred nine fetuses with IUGR underwent a total of 225 ultrasound (US) examinations. We measured the pulsatility index (PI) from the two UAs at the PVC segment, UA in the free floating cord (FFC), middle cerebral artery (MCA), ductus venosus (DV) and the aortic isthmus blood flow index (IFI). Three groups were classified according to bilateral positive end-diastolic (PED) flow, unilateral ARED flow or bilateral ARED flow in the UAs at the PVC segment. RESULTS: The proportions of US examinations with PED flow, unilateral ARED flow and bilateral ARED flow in the UAs were 54.7%, 20.4%, and 24.9%, respectively. At the last US examination, the IFI z-scores were significantly lower in the bilateral ARED group (-6.28±4.30) compared to the unilateral ARED group (-1.72±3.18, p<0.05) and the bilateral PED group (-0.83±2.36, p<0.05), the DV-PI z-scores were significantly higher in the bilateral ARED group (2.15±3.79) compared to the bilateral PED group (0.64±1.50, p<0.05). Before 32 weeks of gestation, the interval between US examination and delivery was significantly shorter in the bilateral ARED group (8.9 days ±8.2) than the unilateral ARED group (15.9 days ±13.4, p<0.05) and the bilateral PED group (30.3 days±25.7, p<0.05). CONCLUSION: There are significant differences in fetal blood fluxes between left and right UA. Doppler examination at the PVC segment significantly improves the comparability of UA-PI between two successive US examinations and allows a longitudinal and independent hemodynamic investigation of each UA. Examination of a single UA in free floating cord may miss a large fraction of unilateral ARED flow. In singleton IUGR fetuses, a bilateral ARED flow in the UAs at the PVC segment indicates more severe hemodynamic compromise and worse fetal conditions than unilateral ARED flow. Public Library of Science 2013-11-27 /pmc/articles/PMC3842244/ /pubmed/24312271 http://dx.doi.org/10.1371/journal.pone.0081160 Text en © 2013 Lecarpentier et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Lecarpentier, Edouard
Cordier, Anne Gaëlle
Proulx, Francine
Fouron, Jean Claude
Gitz, Laurence
Grange, Gilles
Benachi, Alexandra
Tsatsaris, Vassilis
Hemodynamic Impact of Absent or Reverse End-Diastolic Flow in the Two Umbilical Arteries in Growth-Restricted Fetuses
title Hemodynamic Impact of Absent or Reverse End-Diastolic Flow in the Two Umbilical Arteries in Growth-Restricted Fetuses
title_full Hemodynamic Impact of Absent or Reverse End-Diastolic Flow in the Two Umbilical Arteries in Growth-Restricted Fetuses
title_fullStr Hemodynamic Impact of Absent or Reverse End-Diastolic Flow in the Two Umbilical Arteries in Growth-Restricted Fetuses
title_full_unstemmed Hemodynamic Impact of Absent or Reverse End-Diastolic Flow in the Two Umbilical Arteries in Growth-Restricted Fetuses
title_short Hemodynamic Impact of Absent or Reverse End-Diastolic Flow in the Two Umbilical Arteries in Growth-Restricted Fetuses
title_sort hemodynamic impact of absent or reverse end-diastolic flow in the two umbilical arteries in growth-restricted fetuses
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3842244/
https://www.ncbi.nlm.nih.gov/pubmed/24312271
http://dx.doi.org/10.1371/journal.pone.0081160
work_keys_str_mv AT lecarpentieredouard hemodynamicimpactofabsentorreverseenddiastolicflowinthetwoumbilicalarteriesingrowthrestrictedfetuses
AT cordierannegaelle hemodynamicimpactofabsentorreverseenddiastolicflowinthetwoumbilicalarteriesingrowthrestrictedfetuses
AT proulxfrancine hemodynamicimpactofabsentorreverseenddiastolicflowinthetwoumbilicalarteriesingrowthrestrictedfetuses
AT fouronjeanclaude hemodynamicimpactofabsentorreverseenddiastolicflowinthetwoumbilicalarteriesingrowthrestrictedfetuses
AT gitzlaurence hemodynamicimpactofabsentorreverseenddiastolicflowinthetwoumbilicalarteriesingrowthrestrictedfetuses
AT grangegilles hemodynamicimpactofabsentorreverseenddiastolicflowinthetwoumbilicalarteriesingrowthrestrictedfetuses
AT benachialexandra hemodynamicimpactofabsentorreverseenddiastolicflowinthetwoumbilicalarteriesingrowthrestrictedfetuses
AT tsatsarisvassilis hemodynamicimpactofabsentorreverseenddiastolicflowinthetwoumbilicalarteriesingrowthrestrictedfetuses