Cargando…

Forme Fruste Keratoconus Imaging and Validation via Novel Multi-Spot Reflection Topography

BACKGROUND/AIMS: This case report aims to evaluate safety, efficacy and applicability of anterior surface imaging in a patient with forme fruste keratoconus (FFKC) based on a novel multi-spot, multicolor light-emitting-diode (LED) tear film-reflection imaging technology CASE DESCRIPTION: A 45-year-o...

Descripción completa

Detalles Bibliográficos
Autores principales: Kanellopoulos, Anastasios John, Asimellis, George
Formato: Online Artículo Texto
Lenguaje:English
Publicado: S. Karger AG 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3843937/
https://www.ncbi.nlm.nih.gov/pubmed/24348403
http://dx.doi.org/10.1159/000356123
_version_ 1782293117967269888
author Kanellopoulos, Anastasios John
Asimellis, George
author_facet Kanellopoulos, Anastasios John
Asimellis, George
author_sort Kanellopoulos, Anastasios John
collection PubMed
description BACKGROUND/AIMS: This case report aims to evaluate safety, efficacy and applicability of anterior surface imaging in a patient with forme fruste keratoconus (FFKC) based on a novel multi-spot, multicolor light-emitting-diode (LED) tear film-reflection imaging technology CASE DESCRIPTION: A 45-year-old male patient, clinically diagnosed with FFKC, with highly asymmetric manifestation between his eyes, was subjected to the multicolor-spot reflection topography. We investigated elevation and sagittal curvature maps comparatively with the multicolor-spot reflection topographer, a Placido topographer and a Scheimpflug imaging system. For the right eye, steep and flat keratometry values were 41.92 and 41.05 D with the multicolor spot-reflection topographer, 42.30 and 42.08 D with the Placido, and 41.95 and 41.19 D with the Scheimpflug system. For the left eye, steep and flat keratometry values were 41.86 and 41.19 D with the multicolor spot-reflection topographer, 42.06 and 41.66 D with the Placido topographer, and 41.96 and 41.66 D with the Scheimpflug camera. Average repeatability of the keratometry measurements was ±0.35 D for the multicolor spot-reflection topographer, ±0.30 D for the Placido, and ±0.25 D for the Scheimpflug camera. Very good agreement between the instruments was demonstrated on the elevation and curvature maps. CONCLUSION: The ease of use and the comparable results offered by the multicolor spot-reflection topographer, in comparison to established Placido and Scheimpflug imaging, as well as the increased predictability that may be offered by the multicolor spot-reflection topographer, may hold promise for wider clinical application, such as screening of young adults for early keratoconus and, in a much wider perspective, potential candidates for laser corneal refractive surgery.
format Online
Article
Text
id pubmed-3843937
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher S. Karger AG
record_format MEDLINE/PubMed
spelling pubmed-38439372013-12-12 Forme Fruste Keratoconus Imaging and Validation via Novel Multi-Spot Reflection Topography Kanellopoulos, Anastasios John Asimellis, George Case Rep Ophthalmol Published online: October, 2013 BACKGROUND/AIMS: This case report aims to evaluate safety, efficacy and applicability of anterior surface imaging in a patient with forme fruste keratoconus (FFKC) based on a novel multi-spot, multicolor light-emitting-diode (LED) tear film-reflection imaging technology CASE DESCRIPTION: A 45-year-old male patient, clinically diagnosed with FFKC, with highly asymmetric manifestation between his eyes, was subjected to the multicolor-spot reflection topography. We investigated elevation and sagittal curvature maps comparatively with the multicolor-spot reflection topographer, a Placido topographer and a Scheimpflug imaging system. For the right eye, steep and flat keratometry values were 41.92 and 41.05 D with the multicolor spot-reflection topographer, 42.30 and 42.08 D with the Placido, and 41.95 and 41.19 D with the Scheimpflug system. For the left eye, steep and flat keratometry values were 41.86 and 41.19 D with the multicolor spot-reflection topographer, 42.06 and 41.66 D with the Placido topographer, and 41.96 and 41.66 D with the Scheimpflug camera. Average repeatability of the keratometry measurements was ±0.35 D for the multicolor spot-reflection topographer, ±0.30 D for the Placido, and ±0.25 D for the Scheimpflug camera. Very good agreement between the instruments was demonstrated on the elevation and curvature maps. CONCLUSION: The ease of use and the comparable results offered by the multicolor spot-reflection topographer, in comparison to established Placido and Scheimpflug imaging, as well as the increased predictability that may be offered by the multicolor spot-reflection topographer, may hold promise for wider clinical application, such as screening of young adults for early keratoconus and, in a much wider perspective, potential candidates for laser corneal refractive surgery. S. Karger AG 2013-10-25 /pmc/articles/PMC3843937/ /pubmed/24348403 http://dx.doi.org/10.1159/000356123 Text en Copyright © 2013 by S. Karger AG, Basel http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article licensed under the terms of the Creative Commons Attribution-NonCommercial 3.0 Unported license (CC BY-NC) (www.karger.com/OA-license), applicable to the online version of the article only. Users may download, print and share this work on the Internet for noncommercial purposes only, provided the original work is properly cited, and a link to the original work on http://www.karger.com and the terms of this license are included in any shared versions.
spellingShingle Published online: October, 2013
Kanellopoulos, Anastasios John
Asimellis, George
Forme Fruste Keratoconus Imaging and Validation via Novel Multi-Spot Reflection Topography
title Forme Fruste Keratoconus Imaging and Validation via Novel Multi-Spot Reflection Topography
title_full Forme Fruste Keratoconus Imaging and Validation via Novel Multi-Spot Reflection Topography
title_fullStr Forme Fruste Keratoconus Imaging and Validation via Novel Multi-Spot Reflection Topography
title_full_unstemmed Forme Fruste Keratoconus Imaging and Validation via Novel Multi-Spot Reflection Topography
title_short Forme Fruste Keratoconus Imaging and Validation via Novel Multi-Spot Reflection Topography
title_sort forme fruste keratoconus imaging and validation via novel multi-spot reflection topography
topic Published online: October, 2013
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3843937/
https://www.ncbi.nlm.nih.gov/pubmed/24348403
http://dx.doi.org/10.1159/000356123
work_keys_str_mv AT kanellopoulosanastasiosjohn formefrustekeratoconusimagingandvalidationvianovelmultispotreflectiontopography
AT asimellisgeorge formefrustekeratoconusimagingandvalidationvianovelmultispotreflectiontopography