Assessment of Truflex™ articulating stylet versus conventional rigid Portex™ stylet as an intubation guide with the D-blade of C-Mac™ videolaryngoscope during elective tracheal intubation: study protocol for a randomized controlled trial

BACKGROUND: A variety of videolaryngoscopes with angulated blade have been recently introduced into clinical practice. They provide an indirect view of the glottic structures in normal and challenging clinical settings. Despite the very good visualization of the laryngeal structures by these devices...

Descripción completa

Detalles Bibliográficos
Autores principales: Al-Qasmi, Aida, Al-Alawi, Wafa, Malik, Azharuddin Mohammed, Khan, Rashid Manzoor, Kaul, Naresh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3848553/
https://www.ncbi.nlm.nih.gov/pubmed/24041300
http://dx.doi.org/10.1186/1745-6215-14-298
_version_ 1782293777310810112
author Al-Qasmi, Aida
Al-Alawi, Wafa
Malik, Azharuddin Mohammed
Khan, Rashid Manzoor
Kaul, Naresh
author_facet Al-Qasmi, Aida
Al-Alawi, Wafa
Malik, Azharuddin Mohammed
Khan, Rashid Manzoor
Kaul, Naresh
author_sort Al-Qasmi, Aida
collection PubMed
description BACKGROUND: A variety of videolaryngoscopes with angulated blade have been recently introduced into clinical practice. They provide an indirect view of the glottic structures in normal and challenging clinical settings. Despite the very good visualization of the laryngeal structures by these devices, the insertion and advancement of the endotracheal tube may be prolonged and occasionally fail as it does not conform to the enhanced angulation of the blade. To overcome this handicap, it is recommended to use a pre-shaped, styleted tracheal tube during intubation. Unfortunately, these malleable rigid stylets permit only a fixed shape to the advancing endotracheal tube. This may necessitate withdrawal of endotracheal tube-stylet assembly for reshaping, before undertaking a new attempt. This may cause soft tissue injury and hemodynamic disturbance. This single-blinded randomized clinical trial aims to overcome these handicaps using a novel method of dynamically changing the shape of the advancing endotracheal tube by Truflex™ articulating stylet as per need during D-blade C-Mac™ videolaryngoscopy. METHODS: One hundred and fifty four patients between 18 and 60 years of age belonging to either sex undergoing tracheal intubation under uniform general anesthetic technique will be randomly divided into Portex™ malleable stylet group and Truflex™ articulating stylet group. The primary efficacy variable of success/failure between the two groups will be analyzed using the chi square test. For comparison of intubation times and the Intubation Difficulty Score, ANOVA will be used. Primary efficacy endpoint results will be successful or failed tracheal intubation in the first attempt, total intubation time and the intubation difficulty score. Secondary efficacy endpoints will be overall user satisfaction graded from 1 to 10 (1 = very poor, 10 = excellent), Cormack and Lehane’s grading, glotticoscopy time and ETT negotiation time and total number of intubation attempts. Result of safety endpoints will include dental and airway trauma, hemodynamic disturbances, arrhythmias or cardiac arrest. TRIAL REGISTRATION: Current Controlled Trials ISRCTN57679531; Date of registration 12/02/2013
format Online
Article
Text
id pubmed-3848553
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-38485532013-12-04 Assessment of Truflex™ articulating stylet versus conventional rigid Portex™ stylet as an intubation guide with the D-blade of C-Mac™ videolaryngoscope during elective tracheal intubation: study protocol for a randomized controlled trial Al-Qasmi, Aida Al-Alawi, Wafa Malik, Azharuddin Mohammed Khan, Rashid Manzoor Kaul, Naresh Trials Study Protocol BACKGROUND: A variety of videolaryngoscopes with angulated blade have been recently introduced into clinical practice. They provide an indirect view of the glottic structures in normal and challenging clinical settings. Despite the very good visualization of the laryngeal structures by these devices, the insertion and advancement of the endotracheal tube may be prolonged and occasionally fail as it does not conform to the enhanced angulation of the blade. To overcome this handicap, it is recommended to use a pre-shaped, styleted tracheal tube during intubation. Unfortunately, these malleable rigid stylets permit only a fixed shape to the advancing endotracheal tube. This may necessitate withdrawal of endotracheal tube-stylet assembly for reshaping, before undertaking a new attempt. This may cause soft tissue injury and hemodynamic disturbance. This single-blinded randomized clinical trial aims to overcome these handicaps using a novel method of dynamically changing the shape of the advancing endotracheal tube by Truflex™ articulating stylet as per need during D-blade C-Mac™ videolaryngoscopy. METHODS: One hundred and fifty four patients between 18 and 60 years of age belonging to either sex undergoing tracheal intubation under uniform general anesthetic technique will be randomly divided into Portex™ malleable stylet group and Truflex™ articulating stylet group. The primary efficacy variable of success/failure between the two groups will be analyzed using the chi square test. For comparison of intubation times and the Intubation Difficulty Score, ANOVA will be used. Primary efficacy endpoint results will be successful or failed tracheal intubation in the first attempt, total intubation time and the intubation difficulty score. Secondary efficacy endpoints will be overall user satisfaction graded from 1 to 10 (1 = very poor, 10 = excellent), Cormack and Lehane’s grading, glotticoscopy time and ETT negotiation time and total number of intubation attempts. Result of safety endpoints will include dental and airway trauma, hemodynamic disturbances, arrhythmias or cardiac arrest. TRIAL REGISTRATION: Current Controlled Trials ISRCTN57679531; Date of registration 12/02/2013 BioMed Central 2013-09-16 /pmc/articles/PMC3848553/ /pubmed/24041300 http://dx.doi.org/10.1186/1745-6215-14-298 Text en Copyright © 2013 Al-Qasmi et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Study Protocol
Al-Qasmi, Aida
Al-Alawi, Wafa
Malik, Azharuddin Mohammed
Khan, Rashid Manzoor
Kaul, Naresh
Assessment of Truflex™ articulating stylet versus conventional rigid Portex™ stylet as an intubation guide with the D-blade of C-Mac™ videolaryngoscope during elective tracheal intubation: study protocol for a randomized controlled trial
title Assessment of Truflex™ articulating stylet versus conventional rigid Portex™ stylet as an intubation guide with the D-blade of C-Mac™ videolaryngoscope during elective tracheal intubation: study protocol for a randomized controlled trial
title_full Assessment of Truflex™ articulating stylet versus conventional rigid Portex™ stylet as an intubation guide with the D-blade of C-Mac™ videolaryngoscope during elective tracheal intubation: study protocol for a randomized controlled trial
title_fullStr Assessment of Truflex™ articulating stylet versus conventional rigid Portex™ stylet as an intubation guide with the D-blade of C-Mac™ videolaryngoscope during elective tracheal intubation: study protocol for a randomized controlled trial
title_full_unstemmed Assessment of Truflex™ articulating stylet versus conventional rigid Portex™ stylet as an intubation guide with the D-blade of C-Mac™ videolaryngoscope during elective tracheal intubation: study protocol for a randomized controlled trial
title_short Assessment of Truflex™ articulating stylet versus conventional rigid Portex™ stylet as an intubation guide with the D-blade of C-Mac™ videolaryngoscope during elective tracheal intubation: study protocol for a randomized controlled trial
title_sort assessment of truflex™ articulating stylet versus conventional rigid portex™ stylet as an intubation guide with the d-blade of c-mac™ videolaryngoscope during elective tracheal intubation: study protocol for a randomized controlled trial
topic Study Protocol
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3848553/
https://www.ncbi.nlm.nih.gov/pubmed/24041300
http://dx.doi.org/10.1186/1745-6215-14-298
work_keys_str_mv AT alqasmiaida assessmentoftruflexarticulatingstyletversusconventionalrigidportexstyletasanintubationguidewiththedbladeofcmacvideolaryngoscopeduringelectivetrachealintubationstudyprotocolforarandomizedcontrolledtrial
AT alalawiwafa assessmentoftruflexarticulatingstyletversusconventionalrigidportexstyletasanintubationguidewiththedbladeofcmacvideolaryngoscopeduringelectivetrachealintubationstudyprotocolforarandomizedcontrolledtrial
AT malikazharuddinmohammed assessmentoftruflexarticulatingstyletversusconventionalrigidportexstyletasanintubationguidewiththedbladeofcmacvideolaryngoscopeduringelectivetrachealintubationstudyprotocolforarandomizedcontrolledtrial
AT khanrashidmanzoor assessmentoftruflexarticulatingstyletversusconventionalrigidportexstyletasanintubationguidewiththedbladeofcmacvideolaryngoscopeduringelectivetrachealintubationstudyprotocolforarandomizedcontrolledtrial
AT kaulnaresh assessmentoftruflexarticulatingstyletversusconventionalrigidportexstyletasanintubationguidewiththedbladeofcmacvideolaryngoscopeduringelectivetrachealintubationstudyprotocolforarandomizedcontrolledtrial