Validity of a computer-assisted manual segmentation software to quantify wrist erosion volume using computed tomography scans in rheumatoid arthritis

BACKGROUND: To investigate the performance of conventional radiography (CR) for the detection of bone erosions of wrist in rheumatoid arthritis (RA) using multidetector computed tomography (CT) as the reference method and to evaluate the validity of a computer-assisted manual segmentation (outlining...

Descripción completa

Detalles Bibliográficos
Autores principales: Salaffi, Fausto, Carotti, Marina, Ciapetti, Alessandro, Ariani, Alarico, Gasparini, Stefania, Grassi, Walter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3848730/
https://www.ncbi.nlm.nih.gov/pubmed/24028158
http://dx.doi.org/10.1186/1471-2474-14-265
_version_ 1782293808747118592
author Salaffi, Fausto
Carotti, Marina
Ciapetti, Alessandro
Ariani, Alarico
Gasparini, Stefania
Grassi, Walter
author_facet Salaffi, Fausto
Carotti, Marina
Ciapetti, Alessandro
Ariani, Alarico
Gasparini, Stefania
Grassi, Walter
author_sort Salaffi, Fausto
collection PubMed
description BACKGROUND: To investigate the performance of conventional radiography (CR) for the detection of bone erosions of wrist in rheumatoid arthritis (RA) using multidetector computed tomography (CT) as the reference method and to evaluate the validity of a computer-assisted manual segmentation (outlining) technique to quantify erosion volume on CT scans. METHODS: Twenty five RA patients and six controls underwent CT and radiographic evaluation of the dominant wrist on the same day. CT was performed by using a 64 GE light Speed VCT power. Wrists images were evaluated separately and scored for the presence of erosions according to the Outcome Measures in Rheumatology Rheumatoid Arthritis MRI Scoring System (RAMRIS) and the Sharp/van der Heijde scoring method. Measurements of bone erosion volumes were obtained using OsiriX medical imaging software. The mean value of the volumes of the CT bone erosions detected at two readings was used to calculate inter-rater agreement. RESULTS: The overall sensitivity, specificity and accuracy of radiography for detecting erosions were 25.5%, 98.3% and 70.1%, respectively. Using computer-assisted manual segmentation (outlining) technique, erosion volume on CT measurements per subject was ranged from 0.001 cm(3) to 2.01 cm(3). Spearman’s RAMRIS score of each wrist bones in all subjects (n = 25) were correlated with the total erosion volume on CT (p < 0.0001), with the ratio between erosion volume and the corresponding bone volume on a percentage basis (p < 0.0001). The total Sharp/van der Heijde erosion score of the all wrist bones was correlate with the RAMRIS score (p = 0.008). The intraclass correlation coefficients (ICC) for manual segmentation showed high agreement (ICC = 0.901). CONCLUSIONS: Considering CT as the reference method, CR showed very low sensitivity. A close correlation with CT erosion volumes supports the OMERACT RAMRIS erosion score as a semiquantitative measure of joint damage in RA. Although the computer-assisted manual segmentation can be beneficial for diagnostic decision in cross-sectional CT examinations of the wrist in RA, this technique will require further evaluation in terms of responsiveness.
format Online
Article
Text
id pubmed-3848730
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-38487302013-12-05 Validity of a computer-assisted manual segmentation software to quantify wrist erosion volume using computed tomography scans in rheumatoid arthritis Salaffi, Fausto Carotti, Marina Ciapetti, Alessandro Ariani, Alarico Gasparini, Stefania Grassi, Walter BMC Musculoskelet Disord Research Article BACKGROUND: To investigate the performance of conventional radiography (CR) for the detection of bone erosions of wrist in rheumatoid arthritis (RA) using multidetector computed tomography (CT) as the reference method and to evaluate the validity of a computer-assisted manual segmentation (outlining) technique to quantify erosion volume on CT scans. METHODS: Twenty five RA patients and six controls underwent CT and radiographic evaluation of the dominant wrist on the same day. CT was performed by using a 64 GE light Speed VCT power. Wrists images were evaluated separately and scored for the presence of erosions according to the Outcome Measures in Rheumatology Rheumatoid Arthritis MRI Scoring System (RAMRIS) and the Sharp/van der Heijde scoring method. Measurements of bone erosion volumes were obtained using OsiriX medical imaging software. The mean value of the volumes of the CT bone erosions detected at two readings was used to calculate inter-rater agreement. RESULTS: The overall sensitivity, specificity and accuracy of radiography for detecting erosions were 25.5%, 98.3% and 70.1%, respectively. Using computer-assisted manual segmentation (outlining) technique, erosion volume on CT measurements per subject was ranged from 0.001 cm(3) to 2.01 cm(3). Spearman’s RAMRIS score of each wrist bones in all subjects (n = 25) were correlated with the total erosion volume on CT (p < 0.0001), with the ratio between erosion volume and the corresponding bone volume on a percentage basis (p < 0.0001). The total Sharp/van der Heijde erosion score of the all wrist bones was correlate with the RAMRIS score (p = 0.008). The intraclass correlation coefficients (ICC) for manual segmentation showed high agreement (ICC = 0.901). CONCLUSIONS: Considering CT as the reference method, CR showed very low sensitivity. A close correlation with CT erosion volumes supports the OMERACT RAMRIS erosion score as a semiquantitative measure of joint damage in RA. Although the computer-assisted manual segmentation can be beneficial for diagnostic decision in cross-sectional CT examinations of the wrist in RA, this technique will require further evaluation in terms of responsiveness. BioMed Central 2013-09-12 /pmc/articles/PMC3848730/ /pubmed/24028158 http://dx.doi.org/10.1186/1471-2474-14-265 Text en Copyright © 2013 Salaffi et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Salaffi, Fausto
Carotti, Marina
Ciapetti, Alessandro
Ariani, Alarico
Gasparini, Stefania
Grassi, Walter
Validity of a computer-assisted manual segmentation software to quantify wrist erosion volume using computed tomography scans in rheumatoid arthritis
title Validity of a computer-assisted manual segmentation software to quantify wrist erosion volume using computed tomography scans in rheumatoid arthritis
title_full Validity of a computer-assisted manual segmentation software to quantify wrist erosion volume using computed tomography scans in rheumatoid arthritis
title_fullStr Validity of a computer-assisted manual segmentation software to quantify wrist erosion volume using computed tomography scans in rheumatoid arthritis
title_full_unstemmed Validity of a computer-assisted manual segmentation software to quantify wrist erosion volume using computed tomography scans in rheumatoid arthritis
title_short Validity of a computer-assisted manual segmentation software to quantify wrist erosion volume using computed tomography scans in rheumatoid arthritis
title_sort validity of a computer-assisted manual segmentation software to quantify wrist erosion volume using computed tomography scans in rheumatoid arthritis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3848730/
https://www.ncbi.nlm.nih.gov/pubmed/24028158
http://dx.doi.org/10.1186/1471-2474-14-265
work_keys_str_mv AT salaffifausto validityofacomputerassistedmanualsegmentationsoftwaretoquantifywristerosionvolumeusingcomputedtomographyscansinrheumatoidarthritis
AT carottimarina validityofacomputerassistedmanualsegmentationsoftwaretoquantifywristerosionvolumeusingcomputedtomographyscansinrheumatoidarthritis
AT ciapettialessandro validityofacomputerassistedmanualsegmentationsoftwaretoquantifywristerosionvolumeusingcomputedtomographyscansinrheumatoidarthritis
AT arianialarico validityofacomputerassistedmanualsegmentationsoftwaretoquantifywristerosionvolumeusingcomputedtomographyscansinrheumatoidarthritis
AT gasparinistefania validityofacomputerassistedmanualsegmentationsoftwaretoquantifywristerosionvolumeusingcomputedtomographyscansinrheumatoidarthritis
AT grassiwalter validityofacomputerassistedmanualsegmentationsoftwaretoquantifywristerosionvolumeusingcomputedtomographyscansinrheumatoidarthritis