Cargando…

A continuous-time adaptive particle filter for estimations under measurement time uncertainties with an application to a plasma-leucine mixed effects model

BACKGROUND: When mathematical modelling is applied to many different application areas, a common task is the estimation of states and parameters based on measurements. With this kind of inference making, uncertainties in the time when the measurements have been taken are often neglected, but especia...

Descripción completa

Detalles Bibliográficos
Autores principales: Krengel, Annette, Hauth, Jan, Taskinen, Marja-Riitta, Adiels, Martin, Jirstrand, Mats
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3848953/
https://www.ncbi.nlm.nih.gov/pubmed/23331521
http://dx.doi.org/10.1186/1752-0509-7-8
_version_ 1782293853857906688
author Krengel, Annette
Hauth, Jan
Taskinen, Marja-Riitta
Adiels, Martin
Jirstrand, Mats
author_facet Krengel, Annette
Hauth, Jan
Taskinen, Marja-Riitta
Adiels, Martin
Jirstrand, Mats
author_sort Krengel, Annette
collection PubMed
description BACKGROUND: When mathematical modelling is applied to many different application areas, a common task is the estimation of states and parameters based on measurements. With this kind of inference making, uncertainties in the time when the measurements have been taken are often neglected, but especially in applications taken from the life sciences, this kind of errors can considerably influence the estimation results. As an example in the context of personalized medicine, the model-based assessment of the effectiveness of drugs is becoming to play an important role. Systems biology may help here by providing good pharmacokinetic and pharmacodynamic (PK/PD) models. Inference on these systems based on data gained from clinical studies with several patient groups becomes a major challenge. Particle filters are a promising approach to tackle these difficulties but are by itself not ready to handle uncertainties in measurement times. RESULTS: In this article, we describe a variant of the standard particle filter (PF) algorithm which allows state and parameter estimation with the inclusion of measurement time uncertainties (MTU). The modified particle filter, which we call MTU-PF, also allows the application of an adaptive stepsize choice in the time-continuous case to avoid degeneracy problems. The modification is based on the model assumption of uncertain measurement times. While the assumption of randomness in the measurements themselves is common, the corresponding measurement times are generally taken as deterministic and exactly known. Especially in cases where the data are gained from measurements on blood or tissue samples, a relatively high uncertainty in the true measurement time seems to be a natural assumption. Our method is appropriate in cases where relatively few data are used from a relatively large number of groups or individuals, which introduce mixed effects in the model. This is a typical setting of clinical studies. We demonstrate the method on a small artificial example and apply it to a mixed effects model of plasma-leucine kinetics with data from a clinical study which included 34 patients. CONCLUSIONS: Comparisons of our MTU-PF with the standard PF and with an alternative Maximum Likelihood estimation method on the small artificial example clearly show that the MTU-PF obtains better estimations. Considering the application to the data from the clinical study, the MTU-PF shows a similar performance with respect to the quality of estimated parameters compared with the standard particle filter, but besides that, the MTU algorithm shows to be less prone to degeneration than the standard particle filter.
format Online
Article
Text
id pubmed-3848953
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-38489532013-12-06 A continuous-time adaptive particle filter for estimations under measurement time uncertainties with an application to a plasma-leucine mixed effects model Krengel, Annette Hauth, Jan Taskinen, Marja-Riitta Adiels, Martin Jirstrand, Mats BMC Syst Biol Methodology Article BACKGROUND: When mathematical modelling is applied to many different application areas, a common task is the estimation of states and parameters based on measurements. With this kind of inference making, uncertainties in the time when the measurements have been taken are often neglected, but especially in applications taken from the life sciences, this kind of errors can considerably influence the estimation results. As an example in the context of personalized medicine, the model-based assessment of the effectiveness of drugs is becoming to play an important role. Systems biology may help here by providing good pharmacokinetic and pharmacodynamic (PK/PD) models. Inference on these systems based on data gained from clinical studies with several patient groups becomes a major challenge. Particle filters are a promising approach to tackle these difficulties but are by itself not ready to handle uncertainties in measurement times. RESULTS: In this article, we describe a variant of the standard particle filter (PF) algorithm which allows state and parameter estimation with the inclusion of measurement time uncertainties (MTU). The modified particle filter, which we call MTU-PF, also allows the application of an adaptive stepsize choice in the time-continuous case to avoid degeneracy problems. The modification is based on the model assumption of uncertain measurement times. While the assumption of randomness in the measurements themselves is common, the corresponding measurement times are generally taken as deterministic and exactly known. Especially in cases where the data are gained from measurements on blood or tissue samples, a relatively high uncertainty in the true measurement time seems to be a natural assumption. Our method is appropriate in cases where relatively few data are used from a relatively large number of groups or individuals, which introduce mixed effects in the model. This is a typical setting of clinical studies. We demonstrate the method on a small artificial example and apply it to a mixed effects model of plasma-leucine kinetics with data from a clinical study which included 34 patients. CONCLUSIONS: Comparisons of our MTU-PF with the standard PF and with an alternative Maximum Likelihood estimation method on the small artificial example clearly show that the MTU-PF obtains better estimations. Considering the application to the data from the clinical study, the MTU-PF shows a similar performance with respect to the quality of estimated parameters compared with the standard particle filter, but besides that, the MTU algorithm shows to be less prone to degeneration than the standard particle filter. BioMed Central 2013-01-19 /pmc/articles/PMC3848953/ /pubmed/23331521 http://dx.doi.org/10.1186/1752-0509-7-8 Text en Copyright © 2013 Krengel et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Methodology Article
Krengel, Annette
Hauth, Jan
Taskinen, Marja-Riitta
Adiels, Martin
Jirstrand, Mats
A continuous-time adaptive particle filter for estimations under measurement time uncertainties with an application to a plasma-leucine mixed effects model
title A continuous-time adaptive particle filter for estimations under measurement time uncertainties with an application to a plasma-leucine mixed effects model
title_full A continuous-time adaptive particle filter for estimations under measurement time uncertainties with an application to a plasma-leucine mixed effects model
title_fullStr A continuous-time adaptive particle filter for estimations under measurement time uncertainties with an application to a plasma-leucine mixed effects model
title_full_unstemmed A continuous-time adaptive particle filter for estimations under measurement time uncertainties with an application to a plasma-leucine mixed effects model
title_short A continuous-time adaptive particle filter for estimations under measurement time uncertainties with an application to a plasma-leucine mixed effects model
title_sort continuous-time adaptive particle filter for estimations under measurement time uncertainties with an application to a plasma-leucine mixed effects model
topic Methodology Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3848953/
https://www.ncbi.nlm.nih.gov/pubmed/23331521
http://dx.doi.org/10.1186/1752-0509-7-8
work_keys_str_mv AT krengelannette acontinuoustimeadaptiveparticlefilterforestimationsundermeasurementtimeuncertaintieswithanapplicationtoaplasmaleucinemixedeffectsmodel
AT hauthjan acontinuoustimeadaptiveparticlefilterforestimationsundermeasurementtimeuncertaintieswithanapplicationtoaplasmaleucinemixedeffectsmodel
AT taskinenmarjariitta acontinuoustimeadaptiveparticlefilterforestimationsundermeasurementtimeuncertaintieswithanapplicationtoaplasmaleucinemixedeffectsmodel
AT adielsmartin acontinuoustimeadaptiveparticlefilterforestimationsundermeasurementtimeuncertaintieswithanapplicationtoaplasmaleucinemixedeffectsmodel
AT jirstrandmats acontinuoustimeadaptiveparticlefilterforestimationsundermeasurementtimeuncertaintieswithanapplicationtoaplasmaleucinemixedeffectsmodel
AT krengelannette continuoustimeadaptiveparticlefilterforestimationsundermeasurementtimeuncertaintieswithanapplicationtoaplasmaleucinemixedeffectsmodel
AT hauthjan continuoustimeadaptiveparticlefilterforestimationsundermeasurementtimeuncertaintieswithanapplicationtoaplasmaleucinemixedeffectsmodel
AT taskinenmarjariitta continuoustimeadaptiveparticlefilterforestimationsundermeasurementtimeuncertaintieswithanapplicationtoaplasmaleucinemixedeffectsmodel
AT adielsmartin continuoustimeadaptiveparticlefilterforestimationsundermeasurementtimeuncertaintieswithanapplicationtoaplasmaleucinemixedeffectsmodel
AT jirstrandmats continuoustimeadaptiveparticlefilterforestimationsundermeasurementtimeuncertaintieswithanapplicationtoaplasmaleucinemixedeffectsmodel