Cargando…

Flexible fixation of syndesmotic diastasis using the assembled bolt-tightrope system

BACKGROUND: Syndesmotic diastasis is a common injury. Syndesmotic bolt and tightrope are two of the commonly used methods for the fixation of syndesmotic diastasis. Syndesmotic bolt can be used to reduce and maintain the syndesmosis. However, it cannot permit the normal range of motion of distal tib...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Guohui, Chen, Wei, Zhang, Qi, Wang, Juan, Su, Yanling, Zhang, Yingze
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3849036/
https://www.ncbi.nlm.nih.gov/pubmed/24053432
http://dx.doi.org/10.1186/1757-7241-21-71
_version_ 1782293866008805376
author Xu, Guohui
Chen, Wei
Zhang, Qi
Wang, Juan
Su, Yanling
Zhang, Yingze
author_facet Xu, Guohui
Chen, Wei
Zhang, Qi
Wang, Juan
Su, Yanling
Zhang, Yingze
author_sort Xu, Guohui
collection PubMed
description BACKGROUND: Syndesmotic diastasis is a common injury. Syndesmotic bolt and tightrope are two of the commonly used methods for the fixation of syndesmotic diastasis. Syndesmotic bolt can be used to reduce and maintain the syndesmosis. However, it cannot permit the normal range of motion of distal tibiofibular joint, especially the rotation of the fibula. Tightrope technique can be used to provide flexible fixation of the syndesmosis. However, it lacks the ability of reducing the syndesmotic diastasis. To combine the advantages of both syndemostic bolt and tightrope techniques and simultaneously avoid the potential disadvantages of both techniques, we designed the assembled bolt-tightrope system (ABTS). The purpose of this study was to evaluate the primary effectiveness of ABTS in treating syndesmotic diastasis. METHODS: From October 2010 to June 2011, patients with syndesmotic diastasis met the inclusion criteria were enrolled into this study and treated with ABTS. Patients were followed up at 2, 6 weeks and 6, 12 months after operation. The functional outcomes were assessed according to the American Orthopedic Foot and Ankle Society (AOFAS) scores at 12 months follow-up. Patients’ satisfaction was evaluated based upon short form-12 (SF-12) health survey questionnaire. The anteroposterior radiographs of the injured ankles were taken, and the medial clear space (MCS), tibiofibular overlap (TFOL), and tibiofibular clear space (TFCS) were measured. All hardwares were routinely removed at 12-month postoperatively. Follow-ups continued. The functional and radiographic assessments were done again at the latest follow-up. RESULTS: Twelve patients were enrolled into this study, including 8 males and 4 females with a mean age of 39.5 years (range, 26 to 56 years). All patients also sustained ankle fractures. At 12 months follow-up, the mean AOFAS score was 95.4 (range, 85 to 100), and all patients were satisfied with the functional recoveries. The radiographic MCS, TFOL, and TFCS were within the normal range in all patients. After hardware removal, follow-up continued. At the latest follow-up (28 months on average, (range, 25 to 33 months) from internal fixation), the mean AOFAS score was 96.3 (range, 85 to 100), without significant difference with those assessed at 12 months after fixation operations. No syndesmotic diastasis reoccurred based upon the latest radiographic assessment. CONCLUSIONS: ABTS can be used to reduce the syndesmotic diastasis and provide flexible fixation in a minimally invasive fashion. It seems to be an effective alternative technique to treat syndesmotic diastasis.
format Online
Article
Text
id pubmed-3849036
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-38490362013-12-04 Flexible fixation of syndesmotic diastasis using the assembled bolt-tightrope system Xu, Guohui Chen, Wei Zhang, Qi Wang, Juan Su, Yanling Zhang, Yingze Scand J Trauma Resusc Emerg Med Original Research BACKGROUND: Syndesmotic diastasis is a common injury. Syndesmotic bolt and tightrope are two of the commonly used methods for the fixation of syndesmotic diastasis. Syndesmotic bolt can be used to reduce and maintain the syndesmosis. However, it cannot permit the normal range of motion of distal tibiofibular joint, especially the rotation of the fibula. Tightrope technique can be used to provide flexible fixation of the syndesmosis. However, it lacks the ability of reducing the syndesmotic diastasis. To combine the advantages of both syndemostic bolt and tightrope techniques and simultaneously avoid the potential disadvantages of both techniques, we designed the assembled bolt-tightrope system (ABTS). The purpose of this study was to evaluate the primary effectiveness of ABTS in treating syndesmotic diastasis. METHODS: From October 2010 to June 2011, patients with syndesmotic diastasis met the inclusion criteria were enrolled into this study and treated with ABTS. Patients were followed up at 2, 6 weeks and 6, 12 months after operation. The functional outcomes were assessed according to the American Orthopedic Foot and Ankle Society (AOFAS) scores at 12 months follow-up. Patients’ satisfaction was evaluated based upon short form-12 (SF-12) health survey questionnaire. The anteroposterior radiographs of the injured ankles were taken, and the medial clear space (MCS), tibiofibular overlap (TFOL), and tibiofibular clear space (TFCS) were measured. All hardwares were routinely removed at 12-month postoperatively. Follow-ups continued. The functional and radiographic assessments were done again at the latest follow-up. RESULTS: Twelve patients were enrolled into this study, including 8 males and 4 females with a mean age of 39.5 years (range, 26 to 56 years). All patients also sustained ankle fractures. At 12 months follow-up, the mean AOFAS score was 95.4 (range, 85 to 100), and all patients were satisfied with the functional recoveries. The radiographic MCS, TFOL, and TFCS were within the normal range in all patients. After hardware removal, follow-up continued. At the latest follow-up (28 months on average, (range, 25 to 33 months) from internal fixation), the mean AOFAS score was 96.3 (range, 85 to 100), without significant difference with those assessed at 12 months after fixation operations. No syndesmotic diastasis reoccurred based upon the latest radiographic assessment. CONCLUSIONS: ABTS can be used to reduce the syndesmotic diastasis and provide flexible fixation in a minimally invasive fashion. It seems to be an effective alternative technique to treat syndesmotic diastasis. BioMed Central 2013-09-22 /pmc/articles/PMC3849036/ /pubmed/24053432 http://dx.doi.org/10.1186/1757-7241-21-71 Text en Copyright © 2013 Xu et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research
Xu, Guohui
Chen, Wei
Zhang, Qi
Wang, Juan
Su, Yanling
Zhang, Yingze
Flexible fixation of syndesmotic diastasis using the assembled bolt-tightrope system
title Flexible fixation of syndesmotic diastasis using the assembled bolt-tightrope system
title_full Flexible fixation of syndesmotic diastasis using the assembled bolt-tightrope system
title_fullStr Flexible fixation of syndesmotic diastasis using the assembled bolt-tightrope system
title_full_unstemmed Flexible fixation of syndesmotic diastasis using the assembled bolt-tightrope system
title_short Flexible fixation of syndesmotic diastasis using the assembled bolt-tightrope system
title_sort flexible fixation of syndesmotic diastasis using the assembled bolt-tightrope system
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3849036/
https://www.ncbi.nlm.nih.gov/pubmed/24053432
http://dx.doi.org/10.1186/1757-7241-21-71
work_keys_str_mv AT xuguohui flexiblefixationofsyndesmoticdiastasisusingtheassembledbolttightropesystem
AT chenwei flexiblefixationofsyndesmoticdiastasisusingtheassembledbolttightropesystem
AT zhangqi flexiblefixationofsyndesmoticdiastasisusingtheassembledbolttightropesystem
AT wangjuan flexiblefixationofsyndesmoticdiastasisusingtheassembledbolttightropesystem
AT suyanling flexiblefixationofsyndesmoticdiastasisusingtheassembledbolttightropesystem
AT zhangyingze flexiblefixationofsyndesmoticdiastasisusingtheassembledbolttightropesystem