Cargando…

Magnetic resonance imaging-radioguided occult lesion localization (ROLL) in breast cancer using Tc-99m macro-aggregated albumin and distilled water control

BACKGROUND: Magnetic resonance imaging (MRI) guided wire localization presents several challenges apart from the technical difficulties. An alternative to this conventional localization method using a wire is the radio-guided occult lesion localization (ROLL), more related to safe surgical margins a...

Descripción completa

Detalles Bibliográficos
Autores principales: Philadelpho Arantes Pereira, Fernanda, Martins, Gabriela, Gregorio Calas, Maria Julia, Fonseca Torres de Oliveira, Maria Veronica, Gasparetto, Emerson Leandro, Barbosa da Fonseca, Lea Mirian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3849764/
https://www.ncbi.nlm.nih.gov/pubmed/24044428
http://dx.doi.org/10.1186/1471-2342-13-33
_version_ 1782293984541933568
author Philadelpho Arantes Pereira, Fernanda
Martins, Gabriela
Gregorio Calas, Maria Julia
Fonseca Torres de Oliveira, Maria Veronica
Gasparetto, Emerson Leandro
Barbosa da Fonseca, Lea Mirian
author_facet Philadelpho Arantes Pereira, Fernanda
Martins, Gabriela
Gregorio Calas, Maria Julia
Fonseca Torres de Oliveira, Maria Veronica
Gasparetto, Emerson Leandro
Barbosa da Fonseca, Lea Mirian
author_sort Philadelpho Arantes Pereira, Fernanda
collection PubMed
description BACKGROUND: Magnetic resonance imaging (MRI) guided wire localization presents several challenges apart from the technical difficulties. An alternative to this conventional localization method using a wire is the radio-guided occult lesion localization (ROLL), more related to safe surgical margins and reductions in excision volume. The purpose of this study was to establish a safe and reliable magnetic resonance imaging-radioguided occult lesion localization (MRI-ROLL) technique and to report our initial experience with the localization of nonpalpable breast lesions only observed on MRI. METHODS: Sixteen women (mean age 53.2 years) with 17 occult breast lesions underwent radio-guided localization in a 1.5-T MR system using a grid-localizing system. All patients had a diagnostic MRI performed prior to the procedure. An intralesional injection of Technetium-99m macro-aggregated albumin followed by distilled water was performed. After the procedure, scintigraphy was obtained. Surgical resection was performed with the help of a gamma detector probe. The lesion histopathology and imaging concordance; the procedure’s positive predictive value (PPV), duration time, complications, and accuracy; and the rate of exactly excised lesions evaluated with MRI six months after the surgery were assessed. RESULTS: One lesion in one patient had to be excluded because the radioactive substance came back after the injection, requiring a wire placement. Of the remaining cases, there were four malignant lesions, nine benign lesions, and three high-risk lesions. Surgical histopathology and imaging findings were considered concordant in all benign and high-risk cases. The PPV of MRI-ROLL was greater if the indication for the initial MR examination was active breast cancer. The median procedure duration time was 26 minutes, and all included procedures were defined as accurate. The exact and complete lesion removal was confirmed in all (100%) patients who underwent six-month postoperative MRI (50%). CONCLUSIONS: MRI-ROLL offers a precise, technically feasible, safe, and rapid means for performing preoperative MRI localizations in the breast.
format Online
Article
Text
id pubmed-3849764
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-38497642013-12-05 Magnetic resonance imaging-radioguided occult lesion localization (ROLL) in breast cancer using Tc-99m macro-aggregated albumin and distilled water control Philadelpho Arantes Pereira, Fernanda Martins, Gabriela Gregorio Calas, Maria Julia Fonseca Torres de Oliveira, Maria Veronica Gasparetto, Emerson Leandro Barbosa da Fonseca, Lea Mirian BMC Med Imaging Research Article BACKGROUND: Magnetic resonance imaging (MRI) guided wire localization presents several challenges apart from the technical difficulties. An alternative to this conventional localization method using a wire is the radio-guided occult lesion localization (ROLL), more related to safe surgical margins and reductions in excision volume. The purpose of this study was to establish a safe and reliable magnetic resonance imaging-radioguided occult lesion localization (MRI-ROLL) technique and to report our initial experience with the localization of nonpalpable breast lesions only observed on MRI. METHODS: Sixteen women (mean age 53.2 years) with 17 occult breast lesions underwent radio-guided localization in a 1.5-T MR system using a grid-localizing system. All patients had a diagnostic MRI performed prior to the procedure. An intralesional injection of Technetium-99m macro-aggregated albumin followed by distilled water was performed. After the procedure, scintigraphy was obtained. Surgical resection was performed with the help of a gamma detector probe. The lesion histopathology and imaging concordance; the procedure’s positive predictive value (PPV), duration time, complications, and accuracy; and the rate of exactly excised lesions evaluated with MRI six months after the surgery were assessed. RESULTS: One lesion in one patient had to be excluded because the radioactive substance came back after the injection, requiring a wire placement. Of the remaining cases, there were four malignant lesions, nine benign lesions, and three high-risk lesions. Surgical histopathology and imaging findings were considered concordant in all benign and high-risk cases. The PPV of MRI-ROLL was greater if the indication for the initial MR examination was active breast cancer. The median procedure duration time was 26 minutes, and all included procedures were defined as accurate. The exact and complete lesion removal was confirmed in all (100%) patients who underwent six-month postoperative MRI (50%). CONCLUSIONS: MRI-ROLL offers a precise, technically feasible, safe, and rapid means for performing preoperative MRI localizations in the breast. BioMed Central 2013-09-18 /pmc/articles/PMC3849764/ /pubmed/24044428 http://dx.doi.org/10.1186/1471-2342-13-33 Text en Copyright © 2013 Philadelpho Arantes Pereira et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Philadelpho Arantes Pereira, Fernanda
Martins, Gabriela
Gregorio Calas, Maria Julia
Fonseca Torres de Oliveira, Maria Veronica
Gasparetto, Emerson Leandro
Barbosa da Fonseca, Lea Mirian
Magnetic resonance imaging-radioguided occult lesion localization (ROLL) in breast cancer using Tc-99m macro-aggregated albumin and distilled water control
title Magnetic resonance imaging-radioguided occult lesion localization (ROLL) in breast cancer using Tc-99m macro-aggregated albumin and distilled water control
title_full Magnetic resonance imaging-radioguided occult lesion localization (ROLL) in breast cancer using Tc-99m macro-aggregated albumin and distilled water control
title_fullStr Magnetic resonance imaging-radioguided occult lesion localization (ROLL) in breast cancer using Tc-99m macro-aggregated albumin and distilled water control
title_full_unstemmed Magnetic resonance imaging-radioguided occult lesion localization (ROLL) in breast cancer using Tc-99m macro-aggregated albumin and distilled water control
title_short Magnetic resonance imaging-radioguided occult lesion localization (ROLL) in breast cancer using Tc-99m macro-aggregated albumin and distilled water control
title_sort magnetic resonance imaging-radioguided occult lesion localization (roll) in breast cancer using tc-99m macro-aggregated albumin and distilled water control
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3849764/
https://www.ncbi.nlm.nih.gov/pubmed/24044428
http://dx.doi.org/10.1186/1471-2342-13-33
work_keys_str_mv AT philadelphoarantespereirafernanda magneticresonanceimagingradioguidedoccultlesionlocalizationrollinbreastcancerusingtc99mmacroaggregatedalbuminanddistilledwatercontrol
AT martinsgabriela magneticresonanceimagingradioguidedoccultlesionlocalizationrollinbreastcancerusingtc99mmacroaggregatedalbuminanddistilledwatercontrol
AT gregoriocalasmariajulia magneticresonanceimagingradioguidedoccultlesionlocalizationrollinbreastcancerusingtc99mmacroaggregatedalbuminanddistilledwatercontrol
AT fonsecatorresdeoliveiramariaveronica magneticresonanceimagingradioguidedoccultlesionlocalizationrollinbreastcancerusingtc99mmacroaggregatedalbuminanddistilledwatercontrol
AT gasparettoemersonleandro magneticresonanceimagingradioguidedoccultlesionlocalizationrollinbreastcancerusingtc99mmacroaggregatedalbuminanddistilledwatercontrol
AT barbosadafonsecaleamirian magneticresonanceimagingradioguidedoccultlesionlocalizationrollinbreastcancerusingtc99mmacroaggregatedalbuminanddistilledwatercontrol