Cargando…
Monoblock all-polyethylene tibial components have a lower risk of early revision than metal-backed modular components: A registry study of 27,657 primary total knee arthroplasties
BACKGROUND AND PURPOSE: With younger patients seeking reconstructions and the activity-based demands placed on the arthroplasty construct, consideration of the role that implant characteristics play in arthroplasty longevity is warranted. We therefore evaluated the risk of early revision for a monob...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Informa Healthcare
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3851665/ https://www.ncbi.nlm.nih.gov/pubmed/24237424 http://dx.doi.org/10.3109/17453674.2013.862459 |
Sumario: | BACKGROUND AND PURPOSE: With younger patients seeking reconstructions and the activity-based demands placed on the arthroplasty construct, consideration of the role that implant characteristics play in arthroplasty longevity is warranted. We therefore evaluated the risk of early revision for a monoblock all-polyethylene tibial component compared to a metal-backed modular tibial construct with the same articular geometry in a sample of total knee arthroplasties (TKAs). We evaluated risk of revision in younger patients (< 65 years old) and in older patients (≥ 65 years old). METHOD: Fixed primary TKAs with implants from a single manufacturer, performed between April 2001 and December 2010, were analyzed retrospectively. Patient characteristics, surgeon, hospital, procedure, and implant characteristics were compared according to tibial component type (monoblock all-polyethylene vs. metal-backed modular). All-cause revisions and aseptic revisions were evaluated. We used descriptive statistics and Cox regression models. RESULTS: 27,657 TKAs were identified, 2,306 (8%) with monoblock and 25,351 (92%) with modular components. In adjusted models, the risk of early all-cause revision (hazard ratio (HR) = 0.5, 95% confidence interval (CI): 0.3–0.8) and aseptic revision (HR = 0.6, CI: 0.3–1.2) was lower for the monoblock cohort than for the modular cohort. In older patients, the early risk of all-cause revision was 0.6 (CI: 0.4–1.0) for the monoblock cohort compared to the modular cohort. In younger patients, the adjusted risk of all-cause revision (HR = 0.3, CI: 0.1–0.7) and of aseptic revision (HR = 0.3, CI: 0.1–0.7) were lower for the monoblock cohort than for the modular cohort. INTERPRETATION: Overall, monoblock tibial constructs had a 49% lower early risk of all-cause revision and a 41% lower risk of aseptic revision than modular constructs. In younger patients with monoblock components, the early risk of revision for any cause was even lower. |
---|