Cargando…
Adverse reaction to metal debris after ReCap-M2A-Magnum large-diameter-head metal-on-metal total hip arthroplasty
BACKGROUND AND PURPOSE: The clinical findings of adverse reaction to metal debris (ARMD) following large-diameter-head metal-on-metal total hip arthroplasty (LDH MoM THA) may include periarticular fluid collections, soft tissue masses, and gluteal muscle necrosis. The ReCap-M2a-Magnum LDH MoM THA wa...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Informa Healthcare
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3851668/ https://www.ncbi.nlm.nih.gov/pubmed/24171688 http://dx.doi.org/10.3109/17453674.2013.859419 |
_version_ | 1782294324993589248 |
---|---|
author | Mokka, Jari Junnila, Mika Seppänen, Matti Virolainen, Petri Pölönen, Tuukka Vahlberg, Tero Mattila, Kimmo Tuominen, Esa K J Rantakokko, Juho Äärimaa, Ville Kukkonen, Juha Mäkelä, Keijo T |
author_facet | Mokka, Jari Junnila, Mika Seppänen, Matti Virolainen, Petri Pölönen, Tuukka Vahlberg, Tero Mattila, Kimmo Tuominen, Esa K J Rantakokko, Juho Äärimaa, Ville Kukkonen, Juha Mäkelä, Keijo T |
author_sort | Mokka, Jari |
collection | PubMed |
description | BACKGROUND AND PURPOSE: The clinical findings of adverse reaction to metal debris (ARMD) following large-diameter-head metal-on-metal total hip arthroplasty (LDH MoM THA) may include periarticular fluid collections, soft tissue masses, and gluteal muscle necrosis. The ReCap-M2a-Magnum LDH MoM THA was the most commonly used hip device at our institution from 2005 to 2012. We assessed the prevalence of and risk factors for ARMD with this device. METHODS: 74 patients (80 hips) had a ReCap-M2a-Magnum LDH MoM THA during the period August 2005 to December 2006. These patients were studied with hip MRI, serum chromium and cobalt ion measurements, the Oxford hip score questionnaire, and by clinical examination. The prevalence of ARMD was recorded and risk factors for ARMD were assessed using logistic regression models. The mean follow-up time was 6.0 (5.5–6.7) years. RESULTS: A revision operation due to ARMD was needed by 3 of 74 patients (3 of 80 hips). 8 additional patients (8 hips) had definite ARMD, but revision was not performed. 29 patients (32 hips) were considered to have a probable or possible ARMD. Altogether, 43 of 80 hips had a definite, probable, or possible ARMD and 34 patients (37 hips) were considered not to have ARMD. In 46 of 78 hips, MRI revealed a soft tissue mass or a collection of fluid (of any size). The symptoms clicking in the hip, local hip swelling, and a feeling of subluxation were associated with ARMD. INTERPRETATION: ARMD is common after ReCap-M2a-Magnum total hip arthroplasty, and we discourage the use of this device. Asymptomatic patients with a small fluid collection on MRI may not need instant revision surgery but must be followed up closely. |
format | Online Article Text |
id | pubmed-3851668 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Informa Healthcare |
record_format | MEDLINE/PubMed |
spelling | pubmed-38516682013-12-08 Adverse reaction to metal debris after ReCap-M2A-Magnum large-diameter-head metal-on-metal total hip arthroplasty Mokka, Jari Junnila, Mika Seppänen, Matti Virolainen, Petri Pölönen, Tuukka Vahlberg, Tero Mattila, Kimmo Tuominen, Esa K J Rantakokko, Juho Äärimaa, Ville Kukkonen, Juha Mäkelä, Keijo T Acta Orthop Article BACKGROUND AND PURPOSE: The clinical findings of adverse reaction to metal debris (ARMD) following large-diameter-head metal-on-metal total hip arthroplasty (LDH MoM THA) may include periarticular fluid collections, soft tissue masses, and gluteal muscle necrosis. The ReCap-M2a-Magnum LDH MoM THA was the most commonly used hip device at our institution from 2005 to 2012. We assessed the prevalence of and risk factors for ARMD with this device. METHODS: 74 patients (80 hips) had a ReCap-M2a-Magnum LDH MoM THA during the period August 2005 to December 2006. These patients were studied with hip MRI, serum chromium and cobalt ion measurements, the Oxford hip score questionnaire, and by clinical examination. The prevalence of ARMD was recorded and risk factors for ARMD were assessed using logistic regression models. The mean follow-up time was 6.0 (5.5–6.7) years. RESULTS: A revision operation due to ARMD was needed by 3 of 74 patients (3 of 80 hips). 8 additional patients (8 hips) had definite ARMD, but revision was not performed. 29 patients (32 hips) were considered to have a probable or possible ARMD. Altogether, 43 of 80 hips had a definite, probable, or possible ARMD and 34 patients (37 hips) were considered not to have ARMD. In 46 of 78 hips, MRI revealed a soft tissue mass or a collection of fluid (of any size). The symptoms clicking in the hip, local hip swelling, and a feeling of subluxation were associated with ARMD. INTERPRETATION: ARMD is common after ReCap-M2a-Magnum total hip arthroplasty, and we discourage the use of this device. Asymptomatic patients with a small fluid collection on MRI may not need instant revision surgery but must be followed up closely. Informa Healthcare 2013-12 2013-12-02 /pmc/articles/PMC3851668/ /pubmed/24171688 http://dx.doi.org/10.3109/17453674.2013.859419 Text en Copyright: © Nordic Orthopaedic Federation http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited. |
spellingShingle | Article Mokka, Jari Junnila, Mika Seppänen, Matti Virolainen, Petri Pölönen, Tuukka Vahlberg, Tero Mattila, Kimmo Tuominen, Esa K J Rantakokko, Juho Äärimaa, Ville Kukkonen, Juha Mäkelä, Keijo T Adverse reaction to metal debris after ReCap-M2A-Magnum large-diameter-head metal-on-metal total hip arthroplasty |
title | Adverse reaction to metal debris after ReCap-M2A-Magnum large-diameter-head metal-on-metal total hip arthroplasty |
title_full | Adverse reaction to metal debris after ReCap-M2A-Magnum large-diameter-head metal-on-metal total hip arthroplasty |
title_fullStr | Adverse reaction to metal debris after ReCap-M2A-Magnum large-diameter-head metal-on-metal total hip arthroplasty |
title_full_unstemmed | Adverse reaction to metal debris after ReCap-M2A-Magnum large-diameter-head metal-on-metal total hip arthroplasty |
title_short | Adverse reaction to metal debris after ReCap-M2A-Magnum large-diameter-head metal-on-metal total hip arthroplasty |
title_sort | adverse reaction to metal debris after recap-m2a-magnum large-diameter-head metal-on-metal total hip arthroplasty |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3851668/ https://www.ncbi.nlm.nih.gov/pubmed/24171688 http://dx.doi.org/10.3109/17453674.2013.859419 |
work_keys_str_mv | AT mokkajari adversereactiontometaldebrisafterrecapm2amagnumlargediameterheadmetalonmetaltotalhiparthroplasty AT junnilamika adversereactiontometaldebrisafterrecapm2amagnumlargediameterheadmetalonmetaltotalhiparthroplasty AT seppanenmatti adversereactiontometaldebrisafterrecapm2amagnumlargediameterheadmetalonmetaltotalhiparthroplasty AT virolainenpetri adversereactiontometaldebrisafterrecapm2amagnumlargediameterheadmetalonmetaltotalhiparthroplasty AT polonentuukka adversereactiontometaldebrisafterrecapm2amagnumlargediameterheadmetalonmetaltotalhiparthroplasty AT vahlbergtero adversereactiontometaldebrisafterrecapm2amagnumlargediameterheadmetalonmetaltotalhiparthroplasty AT mattilakimmo adversereactiontometaldebrisafterrecapm2amagnumlargediameterheadmetalonmetaltotalhiparthroplasty AT tuominenesakj adversereactiontometaldebrisafterrecapm2amagnumlargediameterheadmetalonmetaltotalhiparthroplasty AT rantakokkojuho adversereactiontometaldebrisafterrecapm2amagnumlargediameterheadmetalonmetaltotalhiparthroplasty AT aarimaaville adversereactiontometaldebrisafterrecapm2amagnumlargediameterheadmetalonmetaltotalhiparthroplasty AT kukkonenjuha adversereactiontometaldebrisafterrecapm2amagnumlargediameterheadmetalonmetaltotalhiparthroplasty AT makelakeijot adversereactiontometaldebrisafterrecapm2amagnumlargediameterheadmetalonmetaltotalhiparthroplasty |