Cargando…

Reliability of clinically relevant 3D foot bone angles from quantitative computed tomography

BACKGROUND: Surgical treatment and clinical management of foot pathology requires accurate, reliable assessment of foot deformities. Foot and ankle deformities are multi-planar and therefore difficult to quantify by standard radiographs. Three-dimensional (3D) imaging modalities have been used to de...

Descripción completa

Detalles Bibliográficos
Autores principales: Gutekunst, David J, Liu, Lu, Ju, Tao, Prior, Fred W, Sinacore, David R
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3852332/
https://www.ncbi.nlm.nih.gov/pubmed/24044376
http://dx.doi.org/10.1186/1757-1146-6-38
_version_ 1782478652259172352
author Gutekunst, David J
Liu, Lu
Ju, Tao
Prior, Fred W
Sinacore, David R
author_facet Gutekunst, David J
Liu, Lu
Ju, Tao
Prior, Fred W
Sinacore, David R
author_sort Gutekunst, David J
collection PubMed
description BACKGROUND: Surgical treatment and clinical management of foot pathology requires accurate, reliable assessment of foot deformities. Foot and ankle deformities are multi-planar and therefore difficult to quantify by standard radiographs. Three-dimensional (3D) imaging modalities have been used to define bone orientations using inertial axes based on bone shape, but these inertial axes can fail to mimic established bone angles used in orthopaedics and clinical biomechanics. To provide improved clinical relevance of 3D bone angles, we developed techniques to define bone axes using landmarks on quantitative computed tomography (QCT) bone surface meshes. We aimed to assess measurement precision of landmark-based, 3D bone-to-bone orientations of hind foot and lesser tarsal bones for expert raters and a template-based automated method. METHODS: Two raters completed two repetitions each for twenty feet (10 right, 10 left), placing anatomic landmarks on the surfaces of calcaneus, talus, cuboid, and navicular. Landmarks were also recorded using the automated, template-based method. For each method, 3D bone axes were computed from landmark positions, and Cardan sequences produced sagittal, frontal, and transverse plane angles of bone-to-bone orientations. Angular reliability was assessed using intraclass correlation coefficients (ICCs) and the root mean square standard deviation (RMS-SD) for intra-rater and inter-rater precision, and rater versus automated agreement. RESULTS: Intra- and inter-rater ICCs were generally high (≥ 0.80), and the ICCs for each rater compared to the automated method were similarly high. RMS-SD intra-rater precision ranged from 1.4 to 3.6° and 2.4 to 6.1°, respectively, for the two raters, which compares favorably to uni-planar radiographic precision. Greatest variability was in Navicular: Talus sagittal plane angle and Cuboid: Calcaneus frontal plane angle. Precision of the automated, atlas-based template method versus the raters was comparable to each rater’s internal precision. CONCLUSIONS: Intra- and inter-rater precision suggest that the landmark-based methods have adequate test-retest reliability for 3D assessment of foot deformities. Agreement of the automated, atlas-based method with the expert raters suggests that the automated method is a valid, time-saving technique for foot deformity assessment. These methods have the potential to improve diagnosis of foot and ankle pathologies by allowing multi-planar quantification of deformities.
format Online
Article
Text
id pubmed-3852332
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-38523322013-12-19 Reliability of clinically relevant 3D foot bone angles from quantitative computed tomography Gutekunst, David J Liu, Lu Ju, Tao Prior, Fred W Sinacore, David R J Foot Ankle Res Methodology BACKGROUND: Surgical treatment and clinical management of foot pathology requires accurate, reliable assessment of foot deformities. Foot and ankle deformities are multi-planar and therefore difficult to quantify by standard radiographs. Three-dimensional (3D) imaging modalities have been used to define bone orientations using inertial axes based on bone shape, but these inertial axes can fail to mimic established bone angles used in orthopaedics and clinical biomechanics. To provide improved clinical relevance of 3D bone angles, we developed techniques to define bone axes using landmarks on quantitative computed tomography (QCT) bone surface meshes. We aimed to assess measurement precision of landmark-based, 3D bone-to-bone orientations of hind foot and lesser tarsal bones for expert raters and a template-based automated method. METHODS: Two raters completed two repetitions each for twenty feet (10 right, 10 left), placing anatomic landmarks on the surfaces of calcaneus, talus, cuboid, and navicular. Landmarks were also recorded using the automated, template-based method. For each method, 3D bone axes were computed from landmark positions, and Cardan sequences produced sagittal, frontal, and transverse plane angles of bone-to-bone orientations. Angular reliability was assessed using intraclass correlation coefficients (ICCs) and the root mean square standard deviation (RMS-SD) for intra-rater and inter-rater precision, and rater versus automated agreement. RESULTS: Intra- and inter-rater ICCs were generally high (≥ 0.80), and the ICCs for each rater compared to the automated method were similarly high. RMS-SD intra-rater precision ranged from 1.4 to 3.6° and 2.4 to 6.1°, respectively, for the two raters, which compares favorably to uni-planar radiographic precision. Greatest variability was in Navicular: Talus sagittal plane angle and Cuboid: Calcaneus frontal plane angle. Precision of the automated, atlas-based template method versus the raters was comparable to each rater’s internal precision. CONCLUSIONS: Intra- and inter-rater precision suggest that the landmark-based methods have adequate test-retest reliability for 3D assessment of foot deformities. Agreement of the automated, atlas-based method with the expert raters suggests that the automated method is a valid, time-saving technique for foot deformity assessment. These methods have the potential to improve diagnosis of foot and ankle pathologies by allowing multi-planar quantification of deformities. BioMed Central 2013-09-17 /pmc/articles/PMC3852332/ /pubmed/24044376 http://dx.doi.org/10.1186/1757-1146-6-38 Text en Copyright © 2013 Gutekunst et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Methodology
Gutekunst, David J
Liu, Lu
Ju, Tao
Prior, Fred W
Sinacore, David R
Reliability of clinically relevant 3D foot bone angles from quantitative computed tomography
title Reliability of clinically relevant 3D foot bone angles from quantitative computed tomography
title_full Reliability of clinically relevant 3D foot bone angles from quantitative computed tomography
title_fullStr Reliability of clinically relevant 3D foot bone angles from quantitative computed tomography
title_full_unstemmed Reliability of clinically relevant 3D foot bone angles from quantitative computed tomography
title_short Reliability of clinically relevant 3D foot bone angles from quantitative computed tomography
title_sort reliability of clinically relevant 3d foot bone angles from quantitative computed tomography
topic Methodology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3852332/
https://www.ncbi.nlm.nih.gov/pubmed/24044376
http://dx.doi.org/10.1186/1757-1146-6-38
work_keys_str_mv AT gutekunstdavidj reliabilityofclinicallyrelevant3dfootboneanglesfromquantitativecomputedtomography
AT liulu reliabilityofclinicallyrelevant3dfootboneanglesfromquantitativecomputedtomography
AT jutao reliabilityofclinicallyrelevant3dfootboneanglesfromquantitativecomputedtomography
AT priorfredw reliabilityofclinicallyrelevant3dfootboneanglesfromquantitativecomputedtomography
AT sinacoredavidr reliabilityofclinicallyrelevant3dfootboneanglesfromquantitativecomputedtomography