Cargando…

A microbiological evaluation of level of disinfection for flexible cystoscopes protected by disposable endosheaths

BACKGROUND: Flexible cystoscopy is used in urological outpatient departments for diagnostic cystoscopy of bladder cancer and requires a high-level disinfection between each patient. The purpose of this study was to make a microbiological post disinfection efficacy assessment of flexible cystoscopes...

Descripción completa

Detalles Bibliográficos
Autores principales: Jørgensen, Peter Hjorth, Slotsbjerg, Torsten, Westh, Henrik, Buitenhuis, Vicki, Hermann, Gregers Gautier
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3852551/
https://www.ncbi.nlm.nih.gov/pubmed/24099332
http://dx.doi.org/10.1186/1471-2490-13-46
Descripción
Sumario:BACKGROUND: Flexible cystoscopy is used in urological outpatient departments for diagnostic cystoscopy of bladder cancer and requires a high-level disinfection between each patient. The purpose of this study was to make a microbiological post disinfection efficacy assessment of flexible cystoscopes (FC) using disposable sterile endosheaths. METHODS: One hundred endosheaths underwent a leak-test for barrier integrity after cystoscopy. Microbiological samples from these cystoscopies were obtained; after removal of the endosheath, and after cleaning the scope with a detergent cloth, rinsing with tap water followed by 70% ethanol disinfection and subsequent drying. The number of colony forming units (cfu) from the samples was counted after 72 hours and then divided in three categories, Clean FC (<5 cfu/sample), Critical FC (5–50 cfu/sample) and High-risk FC (>50 cfu/sample). The result was compared with data of 10 years continuous control sampling recorded in the Copenhagen Clean-Endoscope Quality Control Database (CCQCD) and analyzed with a Chi-square test for homogeneity. RESULTS: All 100 endosheaths passed the leak-test. All samples showed a Clean FC and low means of cfu. A query to the CCQCD, showed that 99.8% (1264/1267) of all FC with a built-in work-channel reprocessed in a WD were clean before use. CONCLUSION: The reprocessing of FC using endosheaths, as preformed in this study, provides a patient-ready procedure. The results display a reprocessing procedure with low risk of pathogen transmission, high patient safety and a valid alternative to the recommended high-level disinfection procedure of FC. However, the general impression was that sheaths slightly reduced vision and resulted in some patient discomfort.