Agreement of Mammographic Measures of Volumetric Breast Density to MRI

BACKGROUND: Clinical scores of mammographic breast density are highly subjective. Automated technologies for mammography exist to quantify breast density objectively, but the technique that most accurately measures the quantity of breast fibroglandular tissue is not known. PURPOSE: To compare the ag...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Jeff, Azziz, Ania, Fan, Bo, Malkov, Serghei, Klifa, Catherine, Newitt, David, Yitta, Silaja, Hylton, Nola, Kerlikowske, Karla, Shepherd, John A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3852736/
https://www.ncbi.nlm.nih.gov/pubmed/24324712
http://dx.doi.org/10.1371/journal.pone.0081653
_version_ 1782478713780174848
author Wang, Jeff
Azziz, Ania
Fan, Bo
Malkov, Serghei
Klifa, Catherine
Newitt, David
Yitta, Silaja
Hylton, Nola
Kerlikowske, Karla
Shepherd, John A.
author_facet Wang, Jeff
Azziz, Ania
Fan, Bo
Malkov, Serghei
Klifa, Catherine
Newitt, David
Yitta, Silaja
Hylton, Nola
Kerlikowske, Karla
Shepherd, John A.
author_sort Wang, Jeff
collection PubMed
description BACKGROUND: Clinical scores of mammographic breast density are highly subjective. Automated technologies for mammography exist to quantify breast density objectively, but the technique that most accurately measures the quantity of breast fibroglandular tissue is not known. PURPOSE: To compare the agreement of three automated mammographic techniques for measuring volumetric breast density with a quantitative volumetric MRI-based technique in a screening population. MATERIALS AND METHODS: Women were selected from the UCSF Medical Center screening population that had received both a screening MRI and digital mammogram within one year of each other, had Breast Imaging Reporting and Data System (BI-RADS) assessments of normal or benign finding, and no history of breast cancer or surgery. Agreement was assessed of three mammographic techniques (Single-energy X-ray Absorptiometry [SXA], Quantra, and Volpara) with MRI for percent fibroglandular tissue volume, absolute fibroglandular tissue volume, and total breast volume. RESULTS: Among 99 women, the automated mammographic density techniques were correlated with MRI measures with R(2) values ranging from 0.40 (log fibroglandular volume) to 0.91 (total breast volume). Substantial agreement measured by kappa statistic was found between all percent fibroglandular tissue measures (0.72 to 0.63), but only moderate agreement for log fibroglandular volumes. The kappa statistics for all percent density measures were highest in the comparisons of the SXA and MRI results. The largest error source between MRI and the mammography techniques was found to be differences in measures of total breast volume. CONCLUSION: Automated volumetric fibroglandular tissue measures from screening digital mammograms were in substantial agreement with MRI and if associated with breast cancer could be used in clinical practice to enhance risk assessment and prevention.
format Online
Article
Text
id pubmed-3852736
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-38527362013-12-09 Agreement of Mammographic Measures of Volumetric Breast Density to MRI Wang, Jeff Azziz, Ania Fan, Bo Malkov, Serghei Klifa, Catherine Newitt, David Yitta, Silaja Hylton, Nola Kerlikowske, Karla Shepherd, John A. PLoS One Research Article BACKGROUND: Clinical scores of mammographic breast density are highly subjective. Automated technologies for mammography exist to quantify breast density objectively, but the technique that most accurately measures the quantity of breast fibroglandular tissue is not known. PURPOSE: To compare the agreement of three automated mammographic techniques for measuring volumetric breast density with a quantitative volumetric MRI-based technique in a screening population. MATERIALS AND METHODS: Women were selected from the UCSF Medical Center screening population that had received both a screening MRI and digital mammogram within one year of each other, had Breast Imaging Reporting and Data System (BI-RADS) assessments of normal or benign finding, and no history of breast cancer or surgery. Agreement was assessed of three mammographic techniques (Single-energy X-ray Absorptiometry [SXA], Quantra, and Volpara) with MRI for percent fibroglandular tissue volume, absolute fibroglandular tissue volume, and total breast volume. RESULTS: Among 99 women, the automated mammographic density techniques were correlated with MRI measures with R(2) values ranging from 0.40 (log fibroglandular volume) to 0.91 (total breast volume). Substantial agreement measured by kappa statistic was found between all percent fibroglandular tissue measures (0.72 to 0.63), but only moderate agreement for log fibroglandular volumes. The kappa statistics for all percent density measures were highest in the comparisons of the SXA and MRI results. The largest error source between MRI and the mammography techniques was found to be differences in measures of total breast volume. CONCLUSION: Automated volumetric fibroglandular tissue measures from screening digital mammograms were in substantial agreement with MRI and if associated with breast cancer could be used in clinical practice to enhance risk assessment and prevention. Public Library of Science 2013-12-04 /pmc/articles/PMC3852736/ /pubmed/24324712 http://dx.doi.org/10.1371/journal.pone.0081653 Text en © 2013 Wang et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Wang, Jeff
Azziz, Ania
Fan, Bo
Malkov, Serghei
Klifa, Catherine
Newitt, David
Yitta, Silaja
Hylton, Nola
Kerlikowske, Karla
Shepherd, John A.
Agreement of Mammographic Measures of Volumetric Breast Density to MRI
title Agreement of Mammographic Measures of Volumetric Breast Density to MRI
title_full Agreement of Mammographic Measures of Volumetric Breast Density to MRI
title_fullStr Agreement of Mammographic Measures of Volumetric Breast Density to MRI
title_full_unstemmed Agreement of Mammographic Measures of Volumetric Breast Density to MRI
title_short Agreement of Mammographic Measures of Volumetric Breast Density to MRI
title_sort agreement of mammographic measures of volumetric breast density to mri
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3852736/
https://www.ncbi.nlm.nih.gov/pubmed/24324712
http://dx.doi.org/10.1371/journal.pone.0081653
work_keys_str_mv AT wangjeff agreementofmammographicmeasuresofvolumetricbreastdensitytomri
AT azzizania agreementofmammographicmeasuresofvolumetricbreastdensitytomri
AT fanbo agreementofmammographicmeasuresofvolumetricbreastdensitytomri
AT malkovserghei agreementofmammographicmeasuresofvolumetricbreastdensitytomri
AT klifacatherine agreementofmammographicmeasuresofvolumetricbreastdensitytomri
AT newittdavid agreementofmammographicmeasuresofvolumetricbreastdensitytomri
AT yittasilaja agreementofmammographicmeasuresofvolumetricbreastdensitytomri
AT hyltonnola agreementofmammographicmeasuresofvolumetricbreastdensitytomri
AT kerlikowskekarla agreementofmammographicmeasuresofvolumetricbreastdensitytomri
AT shepherdjohna agreementofmammographicmeasuresofvolumetricbreastdensitytomri