Cargando…

Evaluation of in vivo efficacy and toxicity of prednisolone-loaded hydrogel-based drug delivery device

Drugs prescribed for the treatment of moderate to severe inflammatory bowel disease (IBD) are associated with number of side effects. Targeted drug delivery is essential for the treatment of inflammatory bowel disease in order to increase efficacy and reduce toxicity. The established delivery system...

Descripción completa

Detalles Bibliográficos
Autores principales: De, Amit Kumar, Bhattacharya, Plaban, Datta, Sriparna, Mukherjee, Arup
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3853763/
https://www.ncbi.nlm.nih.gov/pubmed/24350043
http://dx.doi.org/10.4103/2230-973X.121308
_version_ 1782294689898037248
author De, Amit Kumar
Bhattacharya, Plaban
Datta, Sriparna
Mukherjee, Arup
author_facet De, Amit Kumar
Bhattacharya, Plaban
Datta, Sriparna
Mukherjee, Arup
author_sort De, Amit Kumar
collection PubMed
description Drugs prescribed for the treatment of moderate to severe inflammatory bowel disease (IBD) are associated with number of side effects. Targeted drug delivery is essential for the treatment of inflammatory bowel disease in order to increase efficacy and reduce toxicity. The established delivery system is designed on enzyme and time-based release of poorly soluble prednisolone, a drug of choice for the treatment of moderate to severe inflammatory bowel disease. Their pharmacological evaluation was done in 2,4,6-trinitrobenzene sulphonic acid (TNBS)-induced model of colitis in rat. The drug was administered once daily for 3 consecutive days. Visible severity of colitis, tissue to bodyweight ratio, tissue histology along with nitric oxide (NO), malondialdehyde (MDA) and myeloperoxidase (MPO) activity of colonic tissue were studied to estimate the efficacy of the drug-loaded delivery system. The highest efficacy was observed for formulation in which Eudragit RS100 (EU) was used along with guar gum (GG) in a ratio 2:5 for the preparation of delivery device. An effective recovery was observed from the study of tissue histology of animals treated with the drug-loaded optimized formulation and the biochemical parameters supported it. The toxicity of prednisolone (PD) was reduced significantly as predicted from thymus to body weight ratio of treated animals. GG and EU RS100 provided a newer bipolymer combination for the colon-targeted delivery of PD which increased its efficacy and reduced the toxic side effects. The in vivo experiments presented effective amelioration from colitis in TNBS-induced animal model of colitis.
format Online
Article
Text
id pubmed-3853763
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-38537632013-12-16 Evaluation of in vivo efficacy and toxicity of prednisolone-loaded hydrogel-based drug delivery device De, Amit Kumar Bhattacharya, Plaban Datta, Sriparna Mukherjee, Arup Int J Pharm Investig Original Research Article Drugs prescribed for the treatment of moderate to severe inflammatory bowel disease (IBD) are associated with number of side effects. Targeted drug delivery is essential for the treatment of inflammatory bowel disease in order to increase efficacy and reduce toxicity. The established delivery system is designed on enzyme and time-based release of poorly soluble prednisolone, a drug of choice for the treatment of moderate to severe inflammatory bowel disease. Their pharmacological evaluation was done in 2,4,6-trinitrobenzene sulphonic acid (TNBS)-induced model of colitis in rat. The drug was administered once daily for 3 consecutive days. Visible severity of colitis, tissue to bodyweight ratio, tissue histology along with nitric oxide (NO), malondialdehyde (MDA) and myeloperoxidase (MPO) activity of colonic tissue were studied to estimate the efficacy of the drug-loaded delivery system. The highest efficacy was observed for formulation in which Eudragit RS100 (EU) was used along with guar gum (GG) in a ratio 2:5 for the preparation of delivery device. An effective recovery was observed from the study of tissue histology of animals treated with the drug-loaded optimized formulation and the biochemical parameters supported it. The toxicity of prednisolone (PD) was reduced significantly as predicted from thymus to body weight ratio of treated animals. GG and EU RS100 provided a newer bipolymer combination for the colon-targeted delivery of PD which increased its efficacy and reduced the toxic side effects. The in vivo experiments presented effective amelioration from colitis in TNBS-induced animal model of colitis. Medknow Publications & Media Pvt Ltd 2013 /pmc/articles/PMC3853763/ /pubmed/24350043 http://dx.doi.org/10.4103/2230-973X.121308 Text en Copyright: © International Journal of Pharmaceutical Investigation http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Research Article
De, Amit Kumar
Bhattacharya, Plaban
Datta, Sriparna
Mukherjee, Arup
Evaluation of in vivo efficacy and toxicity of prednisolone-loaded hydrogel-based drug delivery device
title Evaluation of in vivo efficacy and toxicity of prednisolone-loaded hydrogel-based drug delivery device
title_full Evaluation of in vivo efficacy and toxicity of prednisolone-loaded hydrogel-based drug delivery device
title_fullStr Evaluation of in vivo efficacy and toxicity of prednisolone-loaded hydrogel-based drug delivery device
title_full_unstemmed Evaluation of in vivo efficacy and toxicity of prednisolone-loaded hydrogel-based drug delivery device
title_short Evaluation of in vivo efficacy and toxicity of prednisolone-loaded hydrogel-based drug delivery device
title_sort evaluation of in vivo efficacy and toxicity of prednisolone-loaded hydrogel-based drug delivery device
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3853763/
https://www.ncbi.nlm.nih.gov/pubmed/24350043
http://dx.doi.org/10.4103/2230-973X.121308
work_keys_str_mv AT deamitkumar evaluationofinvivoefficacyandtoxicityofprednisoloneloadedhydrogelbaseddrugdeliverydevice
AT bhattacharyaplaban evaluationofinvivoefficacyandtoxicityofprednisoloneloadedhydrogelbaseddrugdeliverydevice
AT dattasriparna evaluationofinvivoefficacyandtoxicityofprednisoloneloadedhydrogelbaseddrugdeliverydevice
AT mukherjeearup evaluationofinvivoefficacyandtoxicityofprednisoloneloadedhydrogelbaseddrugdeliverydevice