Using corrected Cone-Beam CT image for accelerated partial breast irradiation treatment dose verification: the preliminary experience
BACKGROUND: Accurate target localization is mandatory in the accelerated partial breast irradiation (APBI) delivery. Dosimetric verification for positional error will further guarantee the accuracy of treatment delivery. The purpose of this study is to evaluate the clinical feasibility of a cone bea...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3853884/ https://www.ncbi.nlm.nih.gov/pubmed/24034212 http://dx.doi.org/10.1186/1748-717X-8-214 |
_version_ | 1782294706965708800 |
---|---|
author | Wang, Jiazhou Hu, Weigang Cai, Gang Peng, Jiayuan Pan, Ziqiang Guo, Xiaomao Chen, Jiayi |
author_facet | Wang, Jiazhou Hu, Weigang Cai, Gang Peng, Jiayuan Pan, Ziqiang Guo, Xiaomao Chen, Jiayi |
author_sort | Wang, Jiazhou |
collection | PubMed |
description | BACKGROUND: Accurate target localization is mandatory in the accelerated partial breast irradiation (APBI) delivery. Dosimetric verification for positional error will further guarantee the accuracy of treatment delivery. The purpose of this study is to evaluate the clinical feasibility of a cone beam computer tomographic (CBCT) image correction method in APBI. METHODS: A CBCT image correction method was developed. First, rigid image registration was proceeded for CTs and CBCTs; second, these images were separated into four parts; then, ratio images for each of the four parts of planning CTs/CBCTs were calculated and filtered to reduce the high spatial frequency; finally, the enhanced CBCT images were generated combing the four parts. An anthropomorphic thorax rando phantom was used to evaluate the feasibility and accuracy of the CBCT correction method. The CBCT images of consecutive 10 patients receiving APBI were corrected using the above method and dosimetric variations were evaluated. Each set of CBCT is composed of three images: one acquired after skin-marker setup, one after online setup correction and one after treatment delivery. RESULTS: The phantom study showed the improved accuracy of dose calculation with corrected CBCT. The Dose Volume Histogram (DVH) difference between the planning CT and corrected CBCT is less than the difference between the planning CT and original CBCT. The maximum dose difference between the corrected CBCT and planning CT is 0.8% in PTV_EVAL V(100), which is 3.8% between original CBCT and planning. In the patient study, 67.4% of fractions benefit from CBCT setup corrections in PTV_EVAL D95, while in 47.4% of the fractions, reduced dose coverage was found on the post-treatment CBCT. Overall, the CBCT based initial setup correction guaranteed target dose coverage in 9 patients. CONCLUSIONS: A generic CBCT image correction algorithm was created and proved to be easily implemented in clinic. Compared to the original CBCT, the corrected CBCT has more accuracy in dose calculation. The CBCT guided APBI based on initial skin setup is not sufficient to guarantee the accurate dose delivery throughout each fraction. The long treatment delivery time may compromise the target coverage benefits in some patients. |
format | Online Article Text |
id | pubmed-3853884 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-38538842013-12-16 Using corrected Cone-Beam CT image for accelerated partial breast irradiation treatment dose verification: the preliminary experience Wang, Jiazhou Hu, Weigang Cai, Gang Peng, Jiayuan Pan, Ziqiang Guo, Xiaomao Chen, Jiayi Radiat Oncol Research BACKGROUND: Accurate target localization is mandatory in the accelerated partial breast irradiation (APBI) delivery. Dosimetric verification for positional error will further guarantee the accuracy of treatment delivery. The purpose of this study is to evaluate the clinical feasibility of a cone beam computer tomographic (CBCT) image correction method in APBI. METHODS: A CBCT image correction method was developed. First, rigid image registration was proceeded for CTs and CBCTs; second, these images were separated into four parts; then, ratio images for each of the four parts of planning CTs/CBCTs were calculated and filtered to reduce the high spatial frequency; finally, the enhanced CBCT images were generated combing the four parts. An anthropomorphic thorax rando phantom was used to evaluate the feasibility and accuracy of the CBCT correction method. The CBCT images of consecutive 10 patients receiving APBI were corrected using the above method and dosimetric variations were evaluated. Each set of CBCT is composed of three images: one acquired after skin-marker setup, one after online setup correction and one after treatment delivery. RESULTS: The phantom study showed the improved accuracy of dose calculation with corrected CBCT. The Dose Volume Histogram (DVH) difference between the planning CT and corrected CBCT is less than the difference between the planning CT and original CBCT. The maximum dose difference between the corrected CBCT and planning CT is 0.8% in PTV_EVAL V(100), which is 3.8% between original CBCT and planning. In the patient study, 67.4% of fractions benefit from CBCT setup corrections in PTV_EVAL D95, while in 47.4% of the fractions, reduced dose coverage was found on the post-treatment CBCT. Overall, the CBCT based initial setup correction guaranteed target dose coverage in 9 patients. CONCLUSIONS: A generic CBCT image correction algorithm was created and proved to be easily implemented in clinic. Compared to the original CBCT, the corrected CBCT has more accuracy in dose calculation. The CBCT guided APBI based on initial skin setup is not sufficient to guarantee the accurate dose delivery throughout each fraction. The long treatment delivery time may compromise the target coverage benefits in some patients. BioMed Central 2013-09-13 /pmc/articles/PMC3853884/ /pubmed/24034212 http://dx.doi.org/10.1186/1748-717X-8-214 Text en Copyright © 2013 Wang et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Wang, Jiazhou Hu, Weigang Cai, Gang Peng, Jiayuan Pan, Ziqiang Guo, Xiaomao Chen, Jiayi Using corrected Cone-Beam CT image for accelerated partial breast irradiation treatment dose verification: the preliminary experience |
title | Using corrected Cone-Beam CT image for accelerated partial breast irradiation treatment dose verification: the preliminary experience |
title_full | Using corrected Cone-Beam CT image for accelerated partial breast irradiation treatment dose verification: the preliminary experience |
title_fullStr | Using corrected Cone-Beam CT image for accelerated partial breast irradiation treatment dose verification: the preliminary experience |
title_full_unstemmed | Using corrected Cone-Beam CT image for accelerated partial breast irradiation treatment dose verification: the preliminary experience |
title_short | Using corrected Cone-Beam CT image for accelerated partial breast irradiation treatment dose verification: the preliminary experience |
title_sort | using corrected cone-beam ct image for accelerated partial breast irradiation treatment dose verification: the preliminary experience |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3853884/ https://www.ncbi.nlm.nih.gov/pubmed/24034212 http://dx.doi.org/10.1186/1748-717X-8-214 |
work_keys_str_mv | AT wangjiazhou usingcorrectedconebeamctimageforacceleratedpartialbreastirradiationtreatmentdoseverificationthepreliminaryexperience AT huweigang usingcorrectedconebeamctimageforacceleratedpartialbreastirradiationtreatmentdoseverificationthepreliminaryexperience AT caigang usingcorrectedconebeamctimageforacceleratedpartialbreastirradiationtreatmentdoseverificationthepreliminaryexperience AT pengjiayuan usingcorrectedconebeamctimageforacceleratedpartialbreastirradiationtreatmentdoseverificationthepreliminaryexperience AT panziqiang usingcorrectedconebeamctimageforacceleratedpartialbreastirradiationtreatmentdoseverificationthepreliminaryexperience AT guoxiaomao usingcorrectedconebeamctimageforacceleratedpartialbreastirradiationtreatmentdoseverificationthepreliminaryexperience AT chenjiayi usingcorrectedconebeamctimageforacceleratedpartialbreastirradiationtreatmentdoseverificationthepreliminaryexperience |