Human CT Measurements of Structure/Electrode Position Changes During Respiration with Electrical Impedance Tomography

For pulmonary applications of Electrical Impedance Tomography (EIT) systems, the electrodes are placed around the chest in a 2D ring, and the images are reconstructed based on the assumptions that the object is rigid and the measured resistivity change in EIT images is only caused by the actual resi...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Jie, Qin, Lihong, Allen, Tadashi, Patterson, Robert P
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bentham Open 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3856391/
https://www.ncbi.nlm.nih.gov/pubmed/24339836
http://dx.doi.org/10.2174/1874120701307010109
_version_ 1782295052562726912
author Zhang, Jie
Qin, Lihong
Allen, Tadashi
Patterson, Robert P
author_facet Zhang, Jie
Qin, Lihong
Allen, Tadashi
Patterson, Robert P
author_sort Zhang, Jie
collection PubMed
description For pulmonary applications of Electrical Impedance Tomography (EIT) systems, the electrodes are placed around the chest in a 2D ring, and the images are reconstructed based on the assumptions that the object is rigid and the measured resistivity change in EIT images is only caused by the actual resistivity change of tissue. Structural changes are rarely considered. Previous studies have shown that structural changes which result in tissue/organ and electrode position changes tend to introduce artefacts to EIT images of the thorax. Since EIT reconstruction is an ill-posed inverse problem, any small inaccurate assumptions of object may cause large artefacts in reconstructed images. Accurate information on structure/electrode position changes is a need to understand factors contributing to the measured resistivity changes and to improve EIT reconstruction algorithm. Our previous study using MRI technique showed that chest expansion leads to electrode and tissue/organ movements but not significant as proposed. The accuracy of the measurements by MRI may be limited by its relatively low temporal and spatial resolution. In this study, structure/electrode position changes during respiration cycle in patients who underwent chest CT scans are further investigated. For each patient, sixteen fiduciary markers are equally spaced around the surface, the same as the electrode placement for EIT measurements. A CT scanner with respiration-gated ability is used to acquire images of the thorax. CT thoracic images are retrospectively reconstructed corresponding temporally to specific time periods within respiration cycle (from 0% to 90%, every 10%). The average chest expansions are 2 mm in anterior-posterior and -1.6 mm in lateral directions. Inside tissue/organ move down 9.0±2.5 mm with inspiration of tidal volume (0.54±0.14 liters), ranging from 6 mm to 12 mm. During normal quiet respiration, electrode position changes are smaller than expected. No general patterns of electrode position changes are observed. The results in this study provide guidelines for accommodating the motion that may introduce artefacts to EIT images.
format Online
Article
Text
id pubmed-3856391
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Bentham Open
record_format MEDLINE/PubMed
spelling pubmed-38563912013-12-11 Human CT Measurements of Structure/Electrode Position Changes During Respiration with Electrical Impedance Tomography Zhang, Jie Qin, Lihong Allen, Tadashi Patterson, Robert P Open Biomed Eng J Article For pulmonary applications of Electrical Impedance Tomography (EIT) systems, the electrodes are placed around the chest in a 2D ring, and the images are reconstructed based on the assumptions that the object is rigid and the measured resistivity change in EIT images is only caused by the actual resistivity change of tissue. Structural changes are rarely considered. Previous studies have shown that structural changes which result in tissue/organ and electrode position changes tend to introduce artefacts to EIT images of the thorax. Since EIT reconstruction is an ill-posed inverse problem, any small inaccurate assumptions of object may cause large artefacts in reconstructed images. Accurate information on structure/electrode position changes is a need to understand factors contributing to the measured resistivity changes and to improve EIT reconstruction algorithm. Our previous study using MRI technique showed that chest expansion leads to electrode and tissue/organ movements but not significant as proposed. The accuracy of the measurements by MRI may be limited by its relatively low temporal and spatial resolution. In this study, structure/electrode position changes during respiration cycle in patients who underwent chest CT scans are further investigated. For each patient, sixteen fiduciary markers are equally spaced around the surface, the same as the electrode placement for EIT measurements. A CT scanner with respiration-gated ability is used to acquire images of the thorax. CT thoracic images are retrospectively reconstructed corresponding temporally to specific time periods within respiration cycle (from 0% to 90%, every 10%). The average chest expansions are 2 mm in anterior-posterior and -1.6 mm in lateral directions. Inside tissue/organ move down 9.0±2.5 mm with inspiration of tidal volume (0.54±0.14 liters), ranging from 6 mm to 12 mm. During normal quiet respiration, electrode position changes are smaller than expected. No general patterns of electrode position changes are observed. The results in this study provide guidelines for accommodating the motion that may introduce artefacts to EIT images. Bentham Open 2013-11-15 /pmc/articles/PMC3856391/ /pubmed/24339836 http://dx.doi.org/10.2174/1874120701307010109 Text en © Zhang et al.; Licensee Bentham Open. http://creativecommons.org/licenses/by-nc/3.0/ This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.
spellingShingle Article
Zhang, Jie
Qin, Lihong
Allen, Tadashi
Patterson, Robert P
Human CT Measurements of Structure/Electrode Position Changes During Respiration with Electrical Impedance Tomography
title Human CT Measurements of Structure/Electrode Position Changes During Respiration with Electrical Impedance Tomography
title_full Human CT Measurements of Structure/Electrode Position Changes During Respiration with Electrical Impedance Tomography
title_fullStr Human CT Measurements of Structure/Electrode Position Changes During Respiration with Electrical Impedance Tomography
title_full_unstemmed Human CT Measurements of Structure/Electrode Position Changes During Respiration with Electrical Impedance Tomography
title_short Human CT Measurements of Structure/Electrode Position Changes During Respiration with Electrical Impedance Tomography
title_sort human ct measurements of structure/electrode position changes during respiration with electrical impedance tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3856391/
https://www.ncbi.nlm.nih.gov/pubmed/24339836
http://dx.doi.org/10.2174/1874120701307010109
work_keys_str_mv AT zhangjie humanctmeasurementsofstructureelectrodepositionchangesduringrespirationwithelectricalimpedancetomography
AT qinlihong humanctmeasurementsofstructureelectrodepositionchangesduringrespirationwithelectricalimpedancetomography
AT allentadashi humanctmeasurementsofstructureelectrodepositionchangesduringrespirationwithelectricalimpedancetomography
AT pattersonrobertp humanctmeasurementsofstructureelectrodepositionchangesduringrespirationwithelectricalimpedancetomography