Cargando…
Simultaneous quantification of myocardial and blood flow velocities based on duplex mode ultrasound imaging
BACKGROUND: Ultrasound imaging of the heart is a commonly used clinical tool to assess cardiac function. The basis for this analysis is the quantification of cardiac blood flow and myocardial velocities. These are typically measured using different imaging modes and on different cardiac cycles. Howe...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3856612/ https://www.ncbi.nlm.nih.gov/pubmed/24131529 http://dx.doi.org/10.1186/1475-925X-12-107 |
_version_ | 1782295089672880128 |
---|---|
author | Grönlund, Christer Claesson, Kenji D’hooge, Jan Henein, Michael Y Lindqvist, Per |
author_facet | Grönlund, Christer Claesson, Kenji D’hooge, Jan Henein, Michael Y Lindqvist, Per |
author_sort | Grönlund, Christer |
collection | PubMed |
description | BACKGROUND: Ultrasound imaging of the heart is a commonly used clinical tool to assess cardiac function. The basis for this analysis is the quantification of cardiac blood flow and myocardial velocities. These are typically measured using different imaging modes and on different cardiac cycles. However, due to beat-to-beat variations such as irregular heart rhythm and transient events, simultaneous acquisition is preferred. There exists specialized ultrasound systems for this purpose; however, it would be beneficial if this could be achieved using conventional ultrasound systems due to their wide availability. The conventional Duplex mode ultrasound allows simultaneous acquisition, however at a highly reduced spatial and temporal resolution. METHODS: The aim of this work was to present and evaluate the performance of a novel method to recover myocardial tissue velocity using conventional Duplex ultrasound imaging, and to demonstrate its feasibility for the assessment of simultaneous blood flow and myocardial velocity in-vivo. The essence of the method was the estimation of the axial phase shift of robust echogenic structures between subsequent image frames. The performance of the method was evaluated on synthetic tissue mimicking B-mode image sequences at different frame rates (20–60 Hz) and tissue velocities (peak velocities 5-15cm/s), using cardiac deformation and displacement characteristics. The performance was also compared to a standard 2-D speckle tracking technique. RESULTS: The method had an overall high performance at frame rates above 25 Hz, with less than 15% error of the peak diastolic velocity, and less than 10 ms peak timing error. The method showed superior performance compared to the 2-D tracking technique at frame rates below 50 Hz. The in-vivo quantification of simultaneous blood flow and myocardial tissue velocities verified the echocardiographic patterns and features of healthy subjects and the specific patient group. CONCLUSIONS: A novel myocardial velocity quantification method was presented and high performance at frame rates above 25 Hz was shown. In-vivo quantification of simultaneous myocardial and blood flow velocities was feasible using the proposed method and conventional Duplex mode imaging. We propose that the methodology is suitable for retrospective as well as prospective studies on the mechanics and hemodynamics of the heart. |
format | Online Article Text |
id | pubmed-3856612 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-38566122013-12-16 Simultaneous quantification of myocardial and blood flow velocities based on duplex mode ultrasound imaging Grönlund, Christer Claesson, Kenji D’hooge, Jan Henein, Michael Y Lindqvist, Per Biomed Eng Online Research BACKGROUND: Ultrasound imaging of the heart is a commonly used clinical tool to assess cardiac function. The basis for this analysis is the quantification of cardiac blood flow and myocardial velocities. These are typically measured using different imaging modes and on different cardiac cycles. However, due to beat-to-beat variations such as irregular heart rhythm and transient events, simultaneous acquisition is preferred. There exists specialized ultrasound systems for this purpose; however, it would be beneficial if this could be achieved using conventional ultrasound systems due to their wide availability. The conventional Duplex mode ultrasound allows simultaneous acquisition, however at a highly reduced spatial and temporal resolution. METHODS: The aim of this work was to present and evaluate the performance of a novel method to recover myocardial tissue velocity using conventional Duplex ultrasound imaging, and to demonstrate its feasibility for the assessment of simultaneous blood flow and myocardial velocity in-vivo. The essence of the method was the estimation of the axial phase shift of robust echogenic structures between subsequent image frames. The performance of the method was evaluated on synthetic tissue mimicking B-mode image sequences at different frame rates (20–60 Hz) and tissue velocities (peak velocities 5-15cm/s), using cardiac deformation and displacement characteristics. The performance was also compared to a standard 2-D speckle tracking technique. RESULTS: The method had an overall high performance at frame rates above 25 Hz, with less than 15% error of the peak diastolic velocity, and less than 10 ms peak timing error. The method showed superior performance compared to the 2-D tracking technique at frame rates below 50 Hz. The in-vivo quantification of simultaneous blood flow and myocardial tissue velocities verified the echocardiographic patterns and features of healthy subjects and the specific patient group. CONCLUSIONS: A novel myocardial velocity quantification method was presented and high performance at frame rates above 25 Hz was shown. In-vivo quantification of simultaneous myocardial and blood flow velocities was feasible using the proposed method and conventional Duplex mode imaging. We propose that the methodology is suitable for retrospective as well as prospective studies on the mechanics and hemodynamics of the heart. BioMed Central 2013-10-16 /pmc/articles/PMC3856612/ /pubmed/24131529 http://dx.doi.org/10.1186/1475-925X-12-107 Text en Copyright © 2013 Grönlund et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Grönlund, Christer Claesson, Kenji D’hooge, Jan Henein, Michael Y Lindqvist, Per Simultaneous quantification of myocardial and blood flow velocities based on duplex mode ultrasound imaging |
title | Simultaneous quantification of myocardial and blood flow velocities based on duplex mode ultrasound imaging |
title_full | Simultaneous quantification of myocardial and blood flow velocities based on duplex mode ultrasound imaging |
title_fullStr | Simultaneous quantification of myocardial and blood flow velocities based on duplex mode ultrasound imaging |
title_full_unstemmed | Simultaneous quantification of myocardial and blood flow velocities based on duplex mode ultrasound imaging |
title_short | Simultaneous quantification of myocardial and blood flow velocities based on duplex mode ultrasound imaging |
title_sort | simultaneous quantification of myocardial and blood flow velocities based on duplex mode ultrasound imaging |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3856612/ https://www.ncbi.nlm.nih.gov/pubmed/24131529 http://dx.doi.org/10.1186/1475-925X-12-107 |
work_keys_str_mv | AT gronlundchrister simultaneousquantificationofmyocardialandbloodflowvelocitiesbasedonduplexmodeultrasoundimaging AT claessonkenji simultaneousquantificationofmyocardialandbloodflowvelocitiesbasedonduplexmodeultrasoundimaging AT dhoogejan simultaneousquantificationofmyocardialandbloodflowvelocitiesbasedonduplexmodeultrasoundimaging AT heneinmichaely simultaneousquantificationofmyocardialandbloodflowvelocitiesbasedonduplexmodeultrasoundimaging AT lindqvistper simultaneousquantificationofmyocardialandbloodflowvelocitiesbasedonduplexmodeultrasoundimaging |