Cargando…

Hypothermic Machine Perfusion Reduces Delayed Graft Function and Improves One-Year Graft Survival of Kidneys from Expanded Criteria Donors: A Meta-Analysis

BACKGROUND: Expanded criteria donors (ECDs) are currently accepted as potential sources to increase the donor pool and to provide more chances of kidney transplantation for elderly recipients who would not survive long waiting periods. Hypothermic machine perfusion (HMP) is designed to mitigate the...

Descripción completa

Detalles Bibliográficos
Autores principales: Jiao, Baoping, Liu, Shurong, Liu, Hao, Cheng, Donghua, Cheng, Ying, Liu, Yongfeng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3858268/
https://www.ncbi.nlm.nih.gov/pubmed/24339970
http://dx.doi.org/10.1371/journal.pone.0081826
_version_ 1782295257602326528
author Jiao, Baoping
Liu, Shurong
Liu, Hao
Cheng, Donghua
Cheng, Ying
Liu, Yongfeng
author_facet Jiao, Baoping
Liu, Shurong
Liu, Hao
Cheng, Donghua
Cheng, Ying
Liu, Yongfeng
author_sort Jiao, Baoping
collection PubMed
description BACKGROUND: Expanded criteria donors (ECDs) are currently accepted as potential sources to increase the donor pool and to provide more chances of kidney transplantation for elderly recipients who would not survive long waiting periods. Hypothermic machine perfusion (HMP) is designed to mitigate the deleterious effects of simple cold storage (CS) on the quality of preserved organs, particularly when the donor is in a marginal status. METHODS: We compared the transplant outcomes in patients receiving ECD kidneys with either HMP or CS graft preservation. Articles from the MEDLINE, EMBASE and Cochrane Library databases were searched and all studies reporting outcomes from HMP versus CS methods of kidney preservation were included in this meta-analysis. The parameters analyzed included the incidence of delayed graft function (DGF), primary non-function (PNF) and one-year graft and patient survival. RESULTS: A total of seven studies qualified for the review, involving 2374 and 8716 kidney grafts with HMP or CS preservation respectively, all from ECD donors. The incidence of delayed graft function (DGF) was significantly reduced with an odd ratio(OR) of 0.59 (95% CI 0.54–0.66, P<0.001) and one-year graft survival was significantly improved with an OR of 1.12 (95% CI 1.03–1.21, P = 0.005) in HMP preservation compared to CS. However, there was no difference in the incidence of PNF (OR 0.54, 95% CI 0.21–1.40, P = 0.20), and one-year patient survival (OR 0.98, 95% CI 0.94–1.02, P = 0.36) between HMP and CS preservation. CONCLUSIONS: HMP was associated with a reduced incidence of DGF and an with increased one-year graft survival, but it was not associated with the incidence of PNF and one-year patient survival.
format Online
Article
Text
id pubmed-3858268
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-38582682013-12-11 Hypothermic Machine Perfusion Reduces Delayed Graft Function and Improves One-Year Graft Survival of Kidneys from Expanded Criteria Donors: A Meta-Analysis Jiao, Baoping Liu, Shurong Liu, Hao Cheng, Donghua Cheng, Ying Liu, Yongfeng PLoS One Research Article BACKGROUND: Expanded criteria donors (ECDs) are currently accepted as potential sources to increase the donor pool and to provide more chances of kidney transplantation for elderly recipients who would not survive long waiting periods. Hypothermic machine perfusion (HMP) is designed to mitigate the deleterious effects of simple cold storage (CS) on the quality of preserved organs, particularly when the donor is in a marginal status. METHODS: We compared the transplant outcomes in patients receiving ECD kidneys with either HMP or CS graft preservation. Articles from the MEDLINE, EMBASE and Cochrane Library databases were searched and all studies reporting outcomes from HMP versus CS methods of kidney preservation were included in this meta-analysis. The parameters analyzed included the incidence of delayed graft function (DGF), primary non-function (PNF) and one-year graft and patient survival. RESULTS: A total of seven studies qualified for the review, involving 2374 and 8716 kidney grafts with HMP or CS preservation respectively, all from ECD donors. The incidence of delayed graft function (DGF) was significantly reduced with an odd ratio(OR) of 0.59 (95% CI 0.54–0.66, P<0.001) and one-year graft survival was significantly improved with an OR of 1.12 (95% CI 1.03–1.21, P = 0.005) in HMP preservation compared to CS. However, there was no difference in the incidence of PNF (OR 0.54, 95% CI 0.21–1.40, P = 0.20), and one-year patient survival (OR 0.98, 95% CI 0.94–1.02, P = 0.36) between HMP and CS preservation. CONCLUSIONS: HMP was associated with a reduced incidence of DGF and an with increased one-year graft survival, but it was not associated with the incidence of PNF and one-year patient survival. Public Library of Science 2013-12-10 /pmc/articles/PMC3858268/ /pubmed/24339970 http://dx.doi.org/10.1371/journal.pone.0081826 Text en © 2013 Jiao et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Jiao, Baoping
Liu, Shurong
Liu, Hao
Cheng, Donghua
Cheng, Ying
Liu, Yongfeng
Hypothermic Machine Perfusion Reduces Delayed Graft Function and Improves One-Year Graft Survival of Kidneys from Expanded Criteria Donors: A Meta-Analysis
title Hypothermic Machine Perfusion Reduces Delayed Graft Function and Improves One-Year Graft Survival of Kidneys from Expanded Criteria Donors: A Meta-Analysis
title_full Hypothermic Machine Perfusion Reduces Delayed Graft Function and Improves One-Year Graft Survival of Kidneys from Expanded Criteria Donors: A Meta-Analysis
title_fullStr Hypothermic Machine Perfusion Reduces Delayed Graft Function and Improves One-Year Graft Survival of Kidneys from Expanded Criteria Donors: A Meta-Analysis
title_full_unstemmed Hypothermic Machine Perfusion Reduces Delayed Graft Function and Improves One-Year Graft Survival of Kidneys from Expanded Criteria Donors: A Meta-Analysis
title_short Hypothermic Machine Perfusion Reduces Delayed Graft Function and Improves One-Year Graft Survival of Kidneys from Expanded Criteria Donors: A Meta-Analysis
title_sort hypothermic machine perfusion reduces delayed graft function and improves one-year graft survival of kidneys from expanded criteria donors: a meta-analysis
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3858268/
https://www.ncbi.nlm.nih.gov/pubmed/24339970
http://dx.doi.org/10.1371/journal.pone.0081826
work_keys_str_mv AT jiaobaoping hypothermicmachineperfusionreducesdelayedgraftfunctionandimprovesoneyeargraftsurvivalofkidneysfromexpandedcriteriadonorsametaanalysis
AT liushurong hypothermicmachineperfusionreducesdelayedgraftfunctionandimprovesoneyeargraftsurvivalofkidneysfromexpandedcriteriadonorsametaanalysis
AT liuhao hypothermicmachineperfusionreducesdelayedgraftfunctionandimprovesoneyeargraftsurvivalofkidneysfromexpandedcriteriadonorsametaanalysis
AT chengdonghua hypothermicmachineperfusionreducesdelayedgraftfunctionandimprovesoneyeargraftsurvivalofkidneysfromexpandedcriteriadonorsametaanalysis
AT chengying hypothermicmachineperfusionreducesdelayedgraftfunctionandimprovesoneyeargraftsurvivalofkidneysfromexpandedcriteriadonorsametaanalysis
AT liuyongfeng hypothermicmachineperfusionreducesdelayedgraftfunctionandimprovesoneyeargraftsurvivalofkidneysfromexpandedcriteriadonorsametaanalysis