Cargando…

Laparoscopic vaginal vault closure with conventional straight instruments in single-port access total laparoscopic hysterectomy

OBJECTIVE: Laparoscopic vaginal vault closure with conventional straight instruments is the final barrier to single-port access total laparoscopic hysterectomy (SPA-TLH). The aim of this study is to find out the safer, easier, simpler, faster, and even cheaper way to overcome it. METHODS: Vaginal va...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Daehyun, Kim, Juyoung, Jun, Hye Sun, Jeong, Hyangjin, Park, Youngse
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Obstetrics and Gynecology; Korean Society of Contraception and Reproductive Health; Korean Society of Gynecologic Endocrinology; Korean Society of Gynecologic Endoscopy and Minimal Invasive Surgery; Korean Society of Maternal Fetal Medicine; Korean Society of Ultrasound in Obstetrics and Gynecology 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3859010/
https://www.ncbi.nlm.nih.gov/pubmed/24396818
http://dx.doi.org/10.5468/ogs.2013.56.6.389
_version_ 1782295361410301952
author Park, Daehyun
Kim, Juyoung
Jun, Hye Sun
Jeong, Hyangjin
Park, Youngse
author_facet Park, Daehyun
Kim, Juyoung
Jun, Hye Sun
Jeong, Hyangjin
Park, Youngse
author_sort Park, Daehyun
collection PubMed
description OBJECTIVE: Laparoscopic vaginal vault closure with conventional straight instruments is the final barrier to single-port access total laparoscopic hysterectomy (SPA-TLH). The aim of this study is to find out the safer, easier, simpler, faster, and even cheaper way to overcome it. METHODS: Vaginal vault suturing techniques of 152 consecutive single-port access total laparoscopic hysterectomy cases performed by the author in Gangnam CHA Hospital, CHA University from October 1, 2003 to June 30, 2012, were retrospectively analysed with medical records and DVDs. RESULTS: Of 152 patients who were attempted SPA-TLH, 119 patients (78%) were finished their operations without conversion to multi-port laparoscopy or laparotomy. Of women with successful SPA-TLH, 8 cases (7%) were closed their vaginal vaults vaginally (median, 20 minutes; range, 15-44 minutes), and 111 cases (93%) laparoscopically (median, 44 minutes; range, 13-56 minutes). Laparoscopic vault closure techniques were continuous suture (4 cases, 3%; median, 36 minutes; range, 30-45 minutes), interrupted sutures using knot-pusher (7 cases, 6%; median, 52 minutes; range, 48-56 minutes) Endo Stitch suture (2 cases, 2%; median, 32 minutes; range, 13-50 minutes), continuous vault closure using percutaneous sling sutures (PCSS) (92 cases, 77%; median, 40 minutes; range, 19-56 minutes), and continuous vault closure without PCSS (6 cases, 5%; median, 23 minutes; range, 16-31 minutes). CONCLUSION: Laparoscopic vault closure using PCSS in SPA-TLH only with conventional straight instruments is the best way to overcome the barrier and the short-cut to shorten the learning curve to date.
format Online
Article
Text
id pubmed-3859010
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Korean Society of Obstetrics and Gynecology; Korean Society of Contraception and Reproductive Health; Korean Society of Gynecologic Endocrinology; Korean Society of Gynecologic Endoscopy and Minimal Invasive Surgery; Korean Society of Maternal Fetal Medicine; Korean Society of Ultrasound in Obstetrics and Gynecology
record_format MEDLINE/PubMed
spelling pubmed-38590102014-01-06 Laparoscopic vaginal vault closure with conventional straight instruments in single-port access total laparoscopic hysterectomy Park, Daehyun Kim, Juyoung Jun, Hye Sun Jeong, Hyangjin Park, Youngse Obstet Gynecol Sci Original Article OBJECTIVE: Laparoscopic vaginal vault closure with conventional straight instruments is the final barrier to single-port access total laparoscopic hysterectomy (SPA-TLH). The aim of this study is to find out the safer, easier, simpler, faster, and even cheaper way to overcome it. METHODS: Vaginal vault suturing techniques of 152 consecutive single-port access total laparoscopic hysterectomy cases performed by the author in Gangnam CHA Hospital, CHA University from October 1, 2003 to June 30, 2012, were retrospectively analysed with medical records and DVDs. RESULTS: Of 152 patients who were attempted SPA-TLH, 119 patients (78%) were finished their operations without conversion to multi-port laparoscopy or laparotomy. Of women with successful SPA-TLH, 8 cases (7%) were closed their vaginal vaults vaginally (median, 20 minutes; range, 15-44 minutes), and 111 cases (93%) laparoscopically (median, 44 minutes; range, 13-56 minutes). Laparoscopic vault closure techniques were continuous suture (4 cases, 3%; median, 36 minutes; range, 30-45 minutes), interrupted sutures using knot-pusher (7 cases, 6%; median, 52 minutes; range, 48-56 minutes) Endo Stitch suture (2 cases, 2%; median, 32 minutes; range, 13-50 minutes), continuous vault closure using percutaneous sling sutures (PCSS) (92 cases, 77%; median, 40 minutes; range, 19-56 minutes), and continuous vault closure without PCSS (6 cases, 5%; median, 23 minutes; range, 16-31 minutes). CONCLUSION: Laparoscopic vault closure using PCSS in SPA-TLH only with conventional straight instruments is the best way to overcome the barrier and the short-cut to shorten the learning curve to date. Korean Society of Obstetrics and Gynecology; Korean Society of Contraception and Reproductive Health; Korean Society of Gynecologic Endocrinology; Korean Society of Gynecologic Endoscopy and Minimal Invasive Surgery; Korean Society of Maternal Fetal Medicine; Korean Society of Ultrasound in Obstetrics and Gynecology 2013-11 2013-11-15 /pmc/articles/PMC3859010/ /pubmed/24396818 http://dx.doi.org/10.5468/ogs.2013.56.6.389 Text en Copyright © 2013 Korean Society of Obstetrics and Gynecology http://creativecommons.org/licenses/by-nc/3.0/ Articles published in Obstet Gynecol Sci are open-access, distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Park, Daehyun
Kim, Juyoung
Jun, Hye Sun
Jeong, Hyangjin
Park, Youngse
Laparoscopic vaginal vault closure with conventional straight instruments in single-port access total laparoscopic hysterectomy
title Laparoscopic vaginal vault closure with conventional straight instruments in single-port access total laparoscopic hysterectomy
title_full Laparoscopic vaginal vault closure with conventional straight instruments in single-port access total laparoscopic hysterectomy
title_fullStr Laparoscopic vaginal vault closure with conventional straight instruments in single-port access total laparoscopic hysterectomy
title_full_unstemmed Laparoscopic vaginal vault closure with conventional straight instruments in single-port access total laparoscopic hysterectomy
title_short Laparoscopic vaginal vault closure with conventional straight instruments in single-port access total laparoscopic hysterectomy
title_sort laparoscopic vaginal vault closure with conventional straight instruments in single-port access total laparoscopic hysterectomy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3859010/
https://www.ncbi.nlm.nih.gov/pubmed/24396818
http://dx.doi.org/10.5468/ogs.2013.56.6.389
work_keys_str_mv AT parkdaehyun laparoscopicvaginalvaultclosurewithconventionalstraightinstrumentsinsingleportaccesstotallaparoscopichysterectomy
AT kimjuyoung laparoscopicvaginalvaultclosurewithconventionalstraightinstrumentsinsingleportaccesstotallaparoscopichysterectomy
AT junhyesun laparoscopicvaginalvaultclosurewithconventionalstraightinstrumentsinsingleportaccesstotallaparoscopichysterectomy
AT jeonghyangjin laparoscopicvaginalvaultclosurewithconventionalstraightinstrumentsinsingleportaccesstotallaparoscopichysterectomy
AT parkyoungse laparoscopicvaginalvaultclosurewithconventionalstraightinstrumentsinsingleportaccesstotallaparoscopichysterectomy