Cargando…
A Visual Servoing-Based Method for ProCam Systems Calibration
Projector-camera systems are currently used in a wide field of applications, such as 3D reconstruction and augmented reality, and can provide accurate measurements, depending on the configuration and calibration. Frequently, the calibration task is divided into two steps: camera calibration followed...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3859066/ https://www.ncbi.nlm.nih.gov/pubmed/24084121 http://dx.doi.org/10.3390/s131013318 |
_version_ | 1782295373717438464 |
---|---|
author | Berry, Francois Aider, Omar Ait Mosnier, Jeremie |
author_facet | Berry, Francois Aider, Omar Ait Mosnier, Jeremie |
author_sort | Berry, Francois |
collection | PubMed |
description | Projector-camera systems are currently used in a wide field of applications, such as 3D reconstruction and augmented reality, and can provide accurate measurements, depending on the configuration and calibration. Frequently, the calibration task is divided into two steps: camera calibration followed by projector calibration. The latter still poses certain problems that are not easy to solve, such as the difficulty in obtaining a set of 2D–3D points to compute the projection matrix between the projector and the world. Existing methods are either not sufficiently accurate or not flexible. We propose an easy and automatic method to calibrate such systems that consists in projecting a calibration pattern and superimposing it automatically on a known printed pattern. The projected pattern is provided by a virtual camera observing a virtual pattern in an OpenGL model. The projector displays what the virtual camera visualizes. Thus, the projected pattern can be controlled and superimposed on the printed one with the aid of visual servoing. Our experimental results compare favorably with those of other methods considering both usability and accuracy. |
format | Online Article Text |
id | pubmed-3859066 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-38590662013-12-11 A Visual Servoing-Based Method for ProCam Systems Calibration Berry, Francois Aider, Omar Ait Mosnier, Jeremie Sensors (Basel) Article Projector-camera systems are currently used in a wide field of applications, such as 3D reconstruction and augmented reality, and can provide accurate measurements, depending on the configuration and calibration. Frequently, the calibration task is divided into two steps: camera calibration followed by projector calibration. The latter still poses certain problems that are not easy to solve, such as the difficulty in obtaining a set of 2D–3D points to compute the projection matrix between the projector and the world. Existing methods are either not sufficiently accurate or not flexible. We propose an easy and automatic method to calibrate such systems that consists in projecting a calibration pattern and superimposing it automatically on a known printed pattern. The projected pattern is provided by a virtual camera observing a virtual pattern in an OpenGL model. The projector displays what the virtual camera visualizes. Thus, the projected pattern can be controlled and superimposed on the printed one with the aid of visual servoing. Our experimental results compare favorably with those of other methods considering both usability and accuracy. Molecular Diversity Preservation International (MDPI) 2013-10-01 /pmc/articles/PMC3859066/ /pubmed/24084121 http://dx.doi.org/10.3390/s131013318 Text en © 2013 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Berry, Francois Aider, Omar Ait Mosnier, Jeremie A Visual Servoing-Based Method for ProCam Systems Calibration |
title | A Visual Servoing-Based Method for ProCam Systems Calibration |
title_full | A Visual Servoing-Based Method for ProCam Systems Calibration |
title_fullStr | A Visual Servoing-Based Method for ProCam Systems Calibration |
title_full_unstemmed | A Visual Servoing-Based Method for ProCam Systems Calibration |
title_short | A Visual Servoing-Based Method for ProCam Systems Calibration |
title_sort | visual servoing-based method for procam systems calibration |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3859066/ https://www.ncbi.nlm.nih.gov/pubmed/24084121 http://dx.doi.org/10.3390/s131013318 |
work_keys_str_mv | AT berryfrancois avisualservoingbasedmethodforprocamsystemscalibration AT aideromarait avisualservoingbasedmethodforprocamsystemscalibration AT mosnierjeremie avisualservoingbasedmethodforprocamsystemscalibration AT berryfrancois visualservoingbasedmethodforprocamsystemscalibration AT aideromarait visualservoingbasedmethodforprocamsystemscalibration AT mosnierjeremie visualservoingbasedmethodforprocamsystemscalibration |