Cargando…

High-Performance Liquid Chromatographic Determination of Rivastigmine in Human Plasma for Application in Pharmacokinetic Studies

A simple and reproducible HPLC method with spectrophotometric detection was developed for determination of rivastigmine in human plasma. Liquid-liquid extraction of rivastigmine and donepezil (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (2:98 v/v) in alkaline cond...

Descripción completa

Detalles Bibliográficos
Autores principales: Amini, Hossein, Ahmadiani, Abolhassan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shaheed Beheshti University of Medical Sciences 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3862057/
https://www.ncbi.nlm.nih.gov/pubmed/24363716
_version_ 1782295711217352704
author Amini, Hossein
Ahmadiani, Abolhassan
author_facet Amini, Hossein
Ahmadiani, Abolhassan
author_sort Amini, Hossein
collection PubMed
description A simple and reproducible HPLC method with spectrophotometric detection was developed for determination of rivastigmine in human plasma. Liquid-liquid extraction of rivastigmine and donepezil (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (2:98 v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using a Silica column (250 mm × 4.6 mm, 5 μm) under isocratic elution with acetonitrile-50 mM aqueous sodium dihydrogen phosphate (17: 83 v/v, pH 3.1. Analyses were run at a flow-rate of 1.3 mL/min at of 50°C. The recovery was 90.8% and 95.7% for rivastigmine and the internal standard donepezil, respectively. The precision of the method was 2.6% to 9.1% over the concentration range of 0.5-16 ng/mL for rivastigmine in plasma with a linearity greater than 0.999. The method was specific and sensitive, with a quantification limit of 0.5 ng/mL and a detection limit of 0.2 ng/mL in plasma. The method was used for a bioequivalence study in healthy subjects.
format Online
Article
Text
id pubmed-3862057
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Shaheed Beheshti University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-38620572013-12-20 High-Performance Liquid Chromatographic Determination of Rivastigmine in Human Plasma for Application in Pharmacokinetic Studies Amini, Hossein Ahmadiani, Abolhassan Iran J Pharm Res Original Article A simple and reproducible HPLC method with spectrophotometric detection was developed for determination of rivastigmine in human plasma. Liquid-liquid extraction of rivastigmine and donepezil (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (2:98 v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using a Silica column (250 mm × 4.6 mm, 5 μm) under isocratic elution with acetonitrile-50 mM aqueous sodium dihydrogen phosphate (17: 83 v/v, pH 3.1. Analyses were run at a flow-rate of 1.3 mL/min at of 50°C. The recovery was 90.8% and 95.7% for rivastigmine and the internal standard donepezil, respectively. The precision of the method was 2.6% to 9.1% over the concentration range of 0.5-16 ng/mL for rivastigmine in plasma with a linearity greater than 0.999. The method was specific and sensitive, with a quantification limit of 0.5 ng/mL and a detection limit of 0.2 ng/mL in plasma. The method was used for a bioequivalence study in healthy subjects. Shaheed Beheshti University of Medical Sciences 2010 /pmc/articles/PMC3862057/ /pubmed/24363716 Text en © 2010 by School of Pharmacy, Shaheed Beheshti University of Medical Sciences and Health Services This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Amini, Hossein
Ahmadiani, Abolhassan
High-Performance Liquid Chromatographic Determination of Rivastigmine in Human Plasma for Application in Pharmacokinetic Studies
title High-Performance Liquid Chromatographic Determination of Rivastigmine in Human Plasma for Application in Pharmacokinetic Studies
title_full High-Performance Liquid Chromatographic Determination of Rivastigmine in Human Plasma for Application in Pharmacokinetic Studies
title_fullStr High-Performance Liquid Chromatographic Determination of Rivastigmine in Human Plasma for Application in Pharmacokinetic Studies
title_full_unstemmed High-Performance Liquid Chromatographic Determination of Rivastigmine in Human Plasma for Application in Pharmacokinetic Studies
title_short High-Performance Liquid Chromatographic Determination of Rivastigmine in Human Plasma for Application in Pharmacokinetic Studies
title_sort high-performance liquid chromatographic determination of rivastigmine in human plasma for application in pharmacokinetic studies
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3862057/
https://www.ncbi.nlm.nih.gov/pubmed/24363716
work_keys_str_mv AT aminihossein highperformanceliquidchromatographicdeterminationofrivastigmineinhumanplasmaforapplicationinpharmacokineticstudies
AT ahmadianiabolhassan highperformanceliquidchromatographicdeterminationofrivastigmineinhumanplasmaforapplicationinpharmacokineticstudies