Concurrent Tethered Cord Release and Growing-Rod Implantation—Is It Safe?
Study Design Retrospective case series from one institution with a comparison control group. Objective To evaluate the safety of concomitant tethered cord release and growing-rod insertion in individuals with early onset scoliosis. Methods We retrospectively reviewed patients who underwent concurren...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Georg Thieme Verlag KG
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3864420/ https://www.ncbi.nlm.nih.gov/pubmed/24353969 http://dx.doi.org/10.1055/s-0032-1330941 |
_version_ | 1782295928217010176 |
---|---|
author | Oda, Jon E. Shah, Suken A. Mackenzie, William G. Akbarnia, Behrooz A. Yazici, Muharrem |
author_facet | Oda, Jon E. Shah, Suken A. Mackenzie, William G. Akbarnia, Behrooz A. Yazici, Muharrem |
author_sort | Oda, Jon E. |
collection | PubMed |
description | Study Design Retrospective case series from one institution with a comparison control group. Objective To evaluate the safety of concomitant tethered cord release and growing-rod insertion in individuals with early onset scoliosis. Methods We retrospectively reviewed patients who underwent concurrent tethered cord release and growing-rod insertion. We compared our data to a comparison control group of eight patients who underwent staged tethered cord release and growing-rod insertion. Results We identified three patients meeting criteria. There were no neurological complications in the three patients who underwent concomitant surgery. Average immediate postoperative curve correction was 43.3 degrees (47.6%). We identified seven patients who underwent staged surgery from a multicenter prospective database. No neurological complications were reported, and average immediate postoperative correction was 35.1 degrees (46.2%). Conclusion We believe that concurrent tethered cord release and growing-rod insertion can be performed safely with the use of multimodality neurophysiological monitoring techniques. |
format | Online Article Text |
id | pubmed-3864420 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Georg Thieme Verlag KG |
record_format | MEDLINE/PubMed |
spelling | pubmed-38644202013-12-18 Concurrent Tethered Cord Release and Growing-Rod Implantation—Is It Safe? Oda, Jon E. Shah, Suken A. Mackenzie, William G. Akbarnia, Behrooz A. Yazici, Muharrem Global Spine J Article Study Design Retrospective case series from one institution with a comparison control group. Objective To evaluate the safety of concomitant tethered cord release and growing-rod insertion in individuals with early onset scoliosis. Methods We retrospectively reviewed patients who underwent concurrent tethered cord release and growing-rod insertion. We compared our data to a comparison control group of eight patients who underwent staged tethered cord release and growing-rod insertion. Results We identified three patients meeting criteria. There were no neurological complications in the three patients who underwent concomitant surgery. Average immediate postoperative curve correction was 43.3 degrees (47.6%). We identified seven patients who underwent staged surgery from a multicenter prospective database. No neurological complications were reported, and average immediate postoperative correction was 35.1 degrees (46.2%). Conclusion We believe that concurrent tethered cord release and growing-rod insertion can be performed safely with the use of multimodality neurophysiological monitoring techniques. Georg Thieme Verlag KG 2012-12-04 2012-12 /pmc/articles/PMC3864420/ /pubmed/24353969 http://dx.doi.org/10.1055/s-0032-1330941 Text en © Thieme Medical Publishers |
spellingShingle | Article Oda, Jon E. Shah, Suken A. Mackenzie, William G. Akbarnia, Behrooz A. Yazici, Muharrem Concurrent Tethered Cord Release and Growing-Rod Implantation—Is It Safe? |
title | Concurrent Tethered Cord Release and Growing-Rod Implantation—Is It Safe? |
title_full | Concurrent Tethered Cord Release and Growing-Rod Implantation—Is It Safe? |
title_fullStr | Concurrent Tethered Cord Release and Growing-Rod Implantation—Is It Safe? |
title_full_unstemmed | Concurrent Tethered Cord Release and Growing-Rod Implantation—Is It Safe? |
title_short | Concurrent Tethered Cord Release and Growing-Rod Implantation—Is It Safe? |
title_sort | concurrent tethered cord release and growing-rod implantation—is it safe? |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3864420/ https://www.ncbi.nlm.nih.gov/pubmed/24353969 http://dx.doi.org/10.1055/s-0032-1330941 |
work_keys_str_mv | AT odajone concurrenttetheredcordreleaseandgrowingrodimplantationisitsafe AT shahsukena concurrenttetheredcordreleaseandgrowingrodimplantationisitsafe AT mackenziewilliamg concurrenttetheredcordreleaseandgrowingrodimplantationisitsafe AT akbarniabehrooza concurrenttetheredcordreleaseandgrowingrodimplantationisitsafe AT yazicimuharrem concurrenttetheredcordreleaseandgrowingrodimplantationisitsafe |