Cargando…

An Elevated Maternal Plasma Soluble fms-Like Tyrosine Kinase-1 to Placental Growth Factor Ratio at Midtrimester Is a Useful Predictor for Preeclampsia

Background. To assess the ability of mid-trimester sFlt-1/PlGF ratio for prediction of preeclampsia in two different Arabic populations. Methods. This study measured levels of sFlt-1, PlGF, and sFlt-1/PlGF ratio at midtrimester in 83 patients who developed preeclampsia with contemporary 250 matched...

Descripción completa

Detalles Bibliográficos
Autores principales: Hassan, Mahmoud Fathy, Rund, Nancy Mohamed Ali, Salama, Ahmed Husseiny
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3866774/
https://www.ncbi.nlm.nih.gov/pubmed/24367379
http://dx.doi.org/10.1155/2013/202346
_version_ 1782296222921392128
author Hassan, Mahmoud Fathy
Rund, Nancy Mohamed Ali
Salama, Ahmed Husseiny
author_facet Hassan, Mahmoud Fathy
Rund, Nancy Mohamed Ali
Salama, Ahmed Husseiny
author_sort Hassan, Mahmoud Fathy
collection PubMed
description Background. To assess the ability of mid-trimester sFlt-1/PlGF ratio for prediction of preeclampsia in two different Arabic populations. Methods. This study measured levels of sFlt-1, PlGF, and sFlt-1/PlGF ratio at midtrimester in 83 patients who developed preeclampsia with contemporary 250 matched controls. Results. Women subsequently developed preeclampsia had significantly lower PlGF levels and higher sFlt-1 and sFlt-1/PlGF ratio levels than women with normal pregnancies (P < 0.0001 for all). Women who with preterm preeclampsia had significantly higher sFlt-1 and sFlt-1/PlGF ratio than term preeclamptic women (P = 0.01, 0.003, resp.). A cutoff value of 3198 pg/mL for sFlt-1 was able to predict preeclampsia with sensitivity, specificity, and accuracy of 88%, 83.6%, and 84.7%, respectively, with odds ratio (OR) 37.2 [95% confidence interval (CI) 17.7–78.1]. PIGF at cutoff value of 138 pg/mL was able to predict preeclampsia with sensitivity, specificity, and accuracy of 85.5%, 77.2%, and 79.3%, respectively, with OR 20 [95% CI, 10.2–39.5]. The sFlt-1/PIGF ratio at cutoff value of 24.5 was able to predict preeclampsia with sensitivity, specificity, and accuracy of 91.6%, 86.4%, and 87.7%, respectively with OR 67 [95% CI, 29.3–162.1]. Conclusion. Midtrimester sFlt-1/PlGF ratio displayed the highest sensitivity, specificity, accuracy, and OR for prediction of preeclampsia, demonstrating that it may stipulate more effective prediction of preeclampsia development than individual factor assay.
format Online
Article
Text
id pubmed-3866774
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-38667742013-12-23 An Elevated Maternal Plasma Soluble fms-Like Tyrosine Kinase-1 to Placental Growth Factor Ratio at Midtrimester Is a Useful Predictor for Preeclampsia Hassan, Mahmoud Fathy Rund, Nancy Mohamed Ali Salama, Ahmed Husseiny Obstet Gynecol Int Clinical Study Background. To assess the ability of mid-trimester sFlt-1/PlGF ratio for prediction of preeclampsia in two different Arabic populations. Methods. This study measured levels of sFlt-1, PlGF, and sFlt-1/PlGF ratio at midtrimester in 83 patients who developed preeclampsia with contemporary 250 matched controls. Results. Women subsequently developed preeclampsia had significantly lower PlGF levels and higher sFlt-1 and sFlt-1/PlGF ratio levels than women with normal pregnancies (P < 0.0001 for all). Women who with preterm preeclampsia had significantly higher sFlt-1 and sFlt-1/PlGF ratio than term preeclamptic women (P = 0.01, 0.003, resp.). A cutoff value of 3198 pg/mL for sFlt-1 was able to predict preeclampsia with sensitivity, specificity, and accuracy of 88%, 83.6%, and 84.7%, respectively, with odds ratio (OR) 37.2 [95% confidence interval (CI) 17.7–78.1]. PIGF at cutoff value of 138 pg/mL was able to predict preeclampsia with sensitivity, specificity, and accuracy of 85.5%, 77.2%, and 79.3%, respectively, with OR 20 [95% CI, 10.2–39.5]. The sFlt-1/PIGF ratio at cutoff value of 24.5 was able to predict preeclampsia with sensitivity, specificity, and accuracy of 91.6%, 86.4%, and 87.7%, respectively with OR 67 [95% CI, 29.3–162.1]. Conclusion. Midtrimester sFlt-1/PlGF ratio displayed the highest sensitivity, specificity, accuracy, and OR for prediction of preeclampsia, demonstrating that it may stipulate more effective prediction of preeclampsia development than individual factor assay. Hindawi Publishing Corporation 2013 2013-12-04 /pmc/articles/PMC3866774/ /pubmed/24367379 http://dx.doi.org/10.1155/2013/202346 Text en Copyright © 2013 Mahmoud Fathy Hassan et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Study
Hassan, Mahmoud Fathy
Rund, Nancy Mohamed Ali
Salama, Ahmed Husseiny
An Elevated Maternal Plasma Soluble fms-Like Tyrosine Kinase-1 to Placental Growth Factor Ratio at Midtrimester Is a Useful Predictor for Preeclampsia
title An Elevated Maternal Plasma Soluble fms-Like Tyrosine Kinase-1 to Placental Growth Factor Ratio at Midtrimester Is a Useful Predictor for Preeclampsia
title_full An Elevated Maternal Plasma Soluble fms-Like Tyrosine Kinase-1 to Placental Growth Factor Ratio at Midtrimester Is a Useful Predictor for Preeclampsia
title_fullStr An Elevated Maternal Plasma Soluble fms-Like Tyrosine Kinase-1 to Placental Growth Factor Ratio at Midtrimester Is a Useful Predictor for Preeclampsia
title_full_unstemmed An Elevated Maternal Plasma Soluble fms-Like Tyrosine Kinase-1 to Placental Growth Factor Ratio at Midtrimester Is a Useful Predictor for Preeclampsia
title_short An Elevated Maternal Plasma Soluble fms-Like Tyrosine Kinase-1 to Placental Growth Factor Ratio at Midtrimester Is a Useful Predictor for Preeclampsia
title_sort elevated maternal plasma soluble fms-like tyrosine kinase-1 to placental growth factor ratio at midtrimester is a useful predictor for preeclampsia
topic Clinical Study
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3866774/
https://www.ncbi.nlm.nih.gov/pubmed/24367379
http://dx.doi.org/10.1155/2013/202346
work_keys_str_mv AT hassanmahmoudfathy anelevatedmaternalplasmasolublefmsliketyrosinekinase1toplacentalgrowthfactorratioatmidtrimesterisausefulpredictorforpreeclampsia
AT rundnancymohamedali anelevatedmaternalplasmasolublefmsliketyrosinekinase1toplacentalgrowthfactorratioatmidtrimesterisausefulpredictorforpreeclampsia
AT salamaahmedhusseiny anelevatedmaternalplasmasolublefmsliketyrosinekinase1toplacentalgrowthfactorratioatmidtrimesterisausefulpredictorforpreeclampsia
AT hassanmahmoudfathy elevatedmaternalplasmasolublefmsliketyrosinekinase1toplacentalgrowthfactorratioatmidtrimesterisausefulpredictorforpreeclampsia
AT rundnancymohamedali elevatedmaternalplasmasolublefmsliketyrosinekinase1toplacentalgrowthfactorratioatmidtrimesterisausefulpredictorforpreeclampsia
AT salamaahmedhusseiny elevatedmaternalplasmasolublefmsliketyrosinekinase1toplacentalgrowthfactorratioatmidtrimesterisausefulpredictorforpreeclampsia