Cargando…

Use of Tekscan K-Scan Sensors for Retropatellar Pressure Measurement Avoiding Errors during Implantation and the Effects of Shear Forces on the Measurement Precision

Pressure-sensitive K-Scan 4000 sensors (Tekscan, USA) provide new possibilities for the dynamic measurement of force and pressure in biomechanical investigations. We examined the sensors to determine in particular whether they are also suitable for reliable measurements of retropatellar forces and p...

Descripción completa

Detalles Bibliográficos
Autores principales: Wilharm, A., Hurschler, Ch., Dermitas, T., Bohnsack, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3866885/
https://www.ncbi.nlm.nih.gov/pubmed/24369018
http://dx.doi.org/10.1155/2013/829171
_version_ 1782296238873378816
author Wilharm, A.
Hurschler, Ch.
Dermitas, T.
Bohnsack, M.
author_facet Wilharm, A.
Hurschler, Ch.
Dermitas, T.
Bohnsack, M.
author_sort Wilharm, A.
collection PubMed
description Pressure-sensitive K-Scan 4000 sensors (Tekscan, USA) provide new possibilities for the dynamic measurement of force and pressure in biomechanical investigations. We examined the sensors to determine in particular whether they are also suitable for reliable measurements of retropatellar forces and pressures. Insertion approaches were also investigated and a lateral parapatellar arthrotomy supplemented by parapatellar sutures proved to be the most reliable method. The ten human cadaver knees were tested in a knee-simulating machine at a torque of 30 and 40 Nm. Each test cycle involved a dynamic extension from 120° flexion. All recorded parameters showed a decrease of 1-2% per measurement cycle. Although we supplemented the sensors with a Teflon film, the decrease, which was likely caused by shear force, was significant. We evaluated 12 cycles and observed a linear decrease in parameters up to 17.2% (coefficient of regression 0.69–0.99). In our opinion, the linear decrease can be considered a systematic error and can therefore be quantified and accounted for in subsequent experiments. That will ensure reliable retropatellar usage of Tekscan sensors and distinguish the effects of knee joint surgeries from sensor wear-related effects.
format Online
Article
Text
id pubmed-3866885
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-38668852013-12-24 Use of Tekscan K-Scan Sensors for Retropatellar Pressure Measurement Avoiding Errors during Implantation and the Effects of Shear Forces on the Measurement Precision Wilharm, A. Hurschler, Ch. Dermitas, T. Bohnsack, M. Biomed Res Int Research Article Pressure-sensitive K-Scan 4000 sensors (Tekscan, USA) provide new possibilities for the dynamic measurement of force and pressure in biomechanical investigations. We examined the sensors to determine in particular whether they are also suitable for reliable measurements of retropatellar forces and pressures. Insertion approaches were also investigated and a lateral parapatellar arthrotomy supplemented by parapatellar sutures proved to be the most reliable method. The ten human cadaver knees were tested in a knee-simulating machine at a torque of 30 and 40 Nm. Each test cycle involved a dynamic extension from 120° flexion. All recorded parameters showed a decrease of 1-2% per measurement cycle. Although we supplemented the sensors with a Teflon film, the decrease, which was likely caused by shear force, was significant. We evaluated 12 cycles and observed a linear decrease in parameters up to 17.2% (coefficient of regression 0.69–0.99). In our opinion, the linear decrease can be considered a systematic error and can therefore be quantified and accounted for in subsequent experiments. That will ensure reliable retropatellar usage of Tekscan sensors and distinguish the effects of knee joint surgeries from sensor wear-related effects. Hindawi Publishing Corporation 2013 2013-12-03 /pmc/articles/PMC3866885/ /pubmed/24369018 http://dx.doi.org/10.1155/2013/829171 Text en Copyright © 2013 A. Wilharm et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Wilharm, A.
Hurschler, Ch.
Dermitas, T.
Bohnsack, M.
Use of Tekscan K-Scan Sensors for Retropatellar Pressure Measurement Avoiding Errors during Implantation and the Effects of Shear Forces on the Measurement Precision
title Use of Tekscan K-Scan Sensors for Retropatellar Pressure Measurement Avoiding Errors during Implantation and the Effects of Shear Forces on the Measurement Precision
title_full Use of Tekscan K-Scan Sensors for Retropatellar Pressure Measurement Avoiding Errors during Implantation and the Effects of Shear Forces on the Measurement Precision
title_fullStr Use of Tekscan K-Scan Sensors for Retropatellar Pressure Measurement Avoiding Errors during Implantation and the Effects of Shear Forces on the Measurement Precision
title_full_unstemmed Use of Tekscan K-Scan Sensors for Retropatellar Pressure Measurement Avoiding Errors during Implantation and the Effects of Shear Forces on the Measurement Precision
title_short Use of Tekscan K-Scan Sensors for Retropatellar Pressure Measurement Avoiding Errors during Implantation and the Effects of Shear Forces on the Measurement Precision
title_sort use of tekscan k-scan sensors for retropatellar pressure measurement avoiding errors during implantation and the effects of shear forces on the measurement precision
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3866885/
https://www.ncbi.nlm.nih.gov/pubmed/24369018
http://dx.doi.org/10.1155/2013/829171
work_keys_str_mv AT wilharma useoftekscankscansensorsforretropatellarpressuremeasurementavoidingerrorsduringimplantationandtheeffectsofshearforcesonthemeasurementprecision
AT hurschlerch useoftekscankscansensorsforretropatellarpressuremeasurementavoidingerrorsduringimplantationandtheeffectsofshearforcesonthemeasurementprecision
AT dermitast useoftekscankscansensorsforretropatellarpressuremeasurementavoidingerrorsduringimplantationandtheeffectsofshearforcesonthemeasurementprecision
AT bohnsackm useoftekscankscansensorsforretropatellarpressuremeasurementavoidingerrorsduringimplantationandtheeffectsofshearforcesonthemeasurementprecision