Cargando…

Comparison of Vaginal Misoprostol with Foley Catheter for Cervical Ripening and Induction of Labor

At times, despite an unripe cervix, induction of labor may be needed. In these cases, a safe and suitable method should be considered for cervical ripening and pregnancy termination. The aim of this study is the comparison of vaginal misoprostol with Foley catheter for cervical ripening and inductio...

Descripción completa

Detalles Bibliográficos
Autores principales: Vahid Roudsari, Fatemeh, Ayati, Sedigheh, Ghasemi, Marzieh, Hasanzadeh Mofrad, Maliheh, Shakeri, Mohamad Taghi, Farshidi, Farnoush, Shahabian, Masoud
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Shaheed Beheshti University of Medical Sciences 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3869583/
https://www.ncbi.nlm.nih.gov/pubmed/24363694
_version_ 1782296576869269504
author Vahid Roudsari, Fatemeh
Ayati, Sedigheh
Ghasemi, Marzieh
Hasanzadeh Mofrad, Maliheh
Shakeri, Mohamad Taghi
Farshidi, Farnoush
Shahabian, Masoud
author_facet Vahid Roudsari, Fatemeh
Ayati, Sedigheh
Ghasemi, Marzieh
Hasanzadeh Mofrad, Maliheh
Shakeri, Mohamad Taghi
Farshidi, Farnoush
Shahabian, Masoud
author_sort Vahid Roudsari, Fatemeh
collection PubMed
description At times, despite an unripe cervix, induction of labor may be needed. In these cases, a safe and suitable method should be considered for cervical ripening and pregnancy termination. The aim of this study is the comparison of vaginal misoprostol with Foley catheter for cervical ripening and induction of labor. This randomized clinical trial was performed on 108 pregnant women who had referred to the teaching hospitals of Mashhad University of Medical Sciences during a time period of September 2007 to March 2008. These women were randomly divided into two groups: Misoprostol (including 49 patients) and Foley catheter (including 59 patients). For the first group, 25 microgram vaginal misoprostol was administered every 4 h up to maximum 6 doses. For the second group, Foley catheter 18 F, inflated with 50 cc of sterile water, was placed through the internal os of the cervix. Data was analyzed using SPSS software. p < 0.05 was considered statistically significant. Two groups were similar in the view of demographic characteristics, cesarean indications, maternal and fetal outcomes and neonatal outcomes. Vaginal delivery was significantly higher in misoprostol group (89.9 vs. 62.7, p < 0.01). The mean of delivery time was significantly shorter in misoprostol group (11.08 ± 5.6 vs. 13.6 ± 16.0 h, p < 0.05). In the cases of pregnancy termination and unripe cervix, two methods of misoprostol and Foley catheter were considered suitable, but it seemed that misoprostol decreases the delivery time and was needed for the cesarean section.
format Online
Article
Text
id pubmed-3869583
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Shaheed Beheshti University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-38695832013-12-20 Comparison of Vaginal Misoprostol with Foley Catheter for Cervical Ripening and Induction of Labor Vahid Roudsari, Fatemeh Ayati, Sedigheh Ghasemi, Marzieh Hasanzadeh Mofrad, Maliheh Shakeri, Mohamad Taghi Farshidi, Farnoush Shahabian, Masoud Iran J Pharm Res Original Article At times, despite an unripe cervix, induction of labor may be needed. In these cases, a safe and suitable method should be considered for cervical ripening and pregnancy termination. The aim of this study is the comparison of vaginal misoprostol with Foley catheter for cervical ripening and induction of labor. This randomized clinical trial was performed on 108 pregnant women who had referred to the teaching hospitals of Mashhad University of Medical Sciences during a time period of September 2007 to March 2008. These women were randomly divided into two groups: Misoprostol (including 49 patients) and Foley catheter (including 59 patients). For the first group, 25 microgram vaginal misoprostol was administered every 4 h up to maximum 6 doses. For the second group, Foley catheter 18 F, inflated with 50 cc of sterile water, was placed through the internal os of the cervix. Data was analyzed using SPSS software. p < 0.05 was considered statistically significant. Two groups were similar in the view of demographic characteristics, cesarean indications, maternal and fetal outcomes and neonatal outcomes. Vaginal delivery was significantly higher in misoprostol group (89.9 vs. 62.7, p < 0.01). The mean of delivery time was significantly shorter in misoprostol group (11.08 ± 5.6 vs. 13.6 ± 16.0 h, p < 0.05). In the cases of pregnancy termination and unripe cervix, two methods of misoprostol and Foley catheter were considered suitable, but it seemed that misoprostol decreases the delivery time and was needed for the cesarean section. Shaheed Beheshti University of Medical Sciences 2011 /pmc/articles/PMC3869583/ /pubmed/24363694 Text en © 2011 by School of Pharmacy, Shaheed Beheshti University of Medical Sciences and Health Services This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Vahid Roudsari, Fatemeh
Ayati, Sedigheh
Ghasemi, Marzieh
Hasanzadeh Mofrad, Maliheh
Shakeri, Mohamad Taghi
Farshidi, Farnoush
Shahabian, Masoud
Comparison of Vaginal Misoprostol with Foley Catheter for Cervical Ripening and Induction of Labor
title Comparison of Vaginal Misoprostol with Foley Catheter for Cervical Ripening and Induction of Labor
title_full Comparison of Vaginal Misoprostol with Foley Catheter for Cervical Ripening and Induction of Labor
title_fullStr Comparison of Vaginal Misoprostol with Foley Catheter for Cervical Ripening and Induction of Labor
title_full_unstemmed Comparison of Vaginal Misoprostol with Foley Catheter for Cervical Ripening and Induction of Labor
title_short Comparison of Vaginal Misoprostol with Foley Catheter for Cervical Ripening and Induction of Labor
title_sort comparison of vaginal misoprostol with foley catheter for cervical ripening and induction of labor
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3869583/
https://www.ncbi.nlm.nih.gov/pubmed/24363694
work_keys_str_mv AT vahidroudsarifatemeh comparisonofvaginalmisoprostolwithfoleycatheterforcervicalripeningandinductionoflabor
AT ayatisedigheh comparisonofvaginalmisoprostolwithfoleycatheterforcervicalripeningandinductionoflabor
AT ghasemimarzieh comparisonofvaginalmisoprostolwithfoleycatheterforcervicalripeningandinductionoflabor
AT hasanzadehmofradmaliheh comparisonofvaginalmisoprostolwithfoleycatheterforcervicalripeningandinductionoflabor
AT shakerimohamadtaghi comparisonofvaginalmisoprostolwithfoleycatheterforcervicalripeningandinductionoflabor
AT farshidifarnoush comparisonofvaginalmisoprostolwithfoleycatheterforcervicalripeningandinductionoflabor
AT shahabianmasoud comparisonofvaginalmisoprostolwithfoleycatheterforcervicalripeningandinductionoflabor