Cargando…

Development of a quantitative rapid diagnostic test for multibacillary leprosy using smart phone technology

BACKGROUND: Despite efforts to eliminate leprosy as public health problem, delayed diagnosis and disabilities still occur in many countries. Leprosy diagnosis remains based on clinical manifestations and the number of clinicians with expertise in leprosy diagnosis is in decline. We have developed a...

Descripción completa

Detalles Bibliográficos
Autores principales: Paula Vaz Cardoso, Ludimila, Dias, Ronaldo Ferreira, Freitas, Aline Araújo, Hungria, Emerith Mayra, Oliveira, Regiane Morillas, Collovati, Marco, Reed, Steven G, Duthie, Malcolm S, Martins Araújo Stefani, Mariane
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3870957/
https://www.ncbi.nlm.nih.gov/pubmed/24152601
http://dx.doi.org/10.1186/1471-2334-13-497
Descripción
Sumario:BACKGROUND: Despite efforts to eliminate leprosy as public health problem, delayed diagnosis and disabilities still occur in many countries. Leprosy diagnosis remains based on clinical manifestations and the number of clinicians with expertise in leprosy diagnosis is in decline. We have developed a new immunochromatographic test with the goal of producing a simple and rapid system that can be used, with a minimal amount of training, to provide an objective and consistent diagnosis of multibacillary leprosy. METHODS: The test immobilizes two antigens that have been recognized as excellent candidates for serologic diagnosis (the PGL-I mimetic, ND-O, and LID-1), on a nitrocellulose membrane. This allows the detection of specific IgM and IgG antibodies within 20 minutes of the addition of patient sera. Furthermore, we coupled the NDO-LID® rapid tests with a new cell phone-based test reader platform (Smart Reader®) to provide objective interpretation that was both quantifiable and consistent. RESULTS: Direct comparison of serologic responses indicated that the rapid test detected a greater proportion of leprosy patients than a lab-based PGL-I ELISA. While positive responses were detected by PGL-I ELISA in 83.3% of multibacillary patients and 15.4% of paucibacillary patients, these numbers were increased to 87% and 21.2%, respectively, when a combination of the NDO-LID® test and Smart Reader® was used. Among multibacillary leprosy the sensitivity of NDO-LID® test assessed by Smart Reader® was 87% (95% CI, 79.2-92.7%) and the specificity was 96.1% (95% CI, 91.7- 98.6%). The positive predictive value and the negative predictive value of NDO-LID® tests were 94% (95% CI, 87.4-97.8%) and 91.4% (95% CI, 85.9-95.2%), respectively. CONCLUSION: The widespread provision of rapid diagnostic tests to facilitate the diagnosis or prognosis of multibacillary leprosy could impact on leprosy control programs by aiding early detection, directing appropriate treatment and potentially interrupting Mycobacterium leprae transmission.