Cargando…

An Ion-selective Electrode for Anion Perchlorate in Thick-film Technology

The ionophore 1,4,7,10,13-penta(n-octyl)-1,4,7,10,13-pentaazacyclopentadecane (L(1)) was used for the development of miniaturised perchlorate-selective electrodes in thick-film technology. Different PVC membranes containing L(1) and the plasticizers o-nitrophenyl octyl ether (NPOE), dibutyl phthalat...

Descripción completa

Detalles Bibliográficos
Autores principales: Segui, María Jesús, Lizondo-Sabater, Josefa, Martínez-Máñez, Ramon, Sancenon, Félix, Soto, Juan, Garcia-Breijo, Eduardo, Gil, Luis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2006
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3872339/
_version_ 1782296949738700800
author Segui, María Jesús
Lizondo-Sabater, Josefa
Martínez-Máñez, Ramon
Sancenon, Félix
Soto, Juan
Garcia-Breijo, Eduardo
Gil, Luis
author_facet Segui, María Jesús
Lizondo-Sabater, Josefa
Martínez-Máñez, Ramon
Sancenon, Félix
Soto, Juan
Garcia-Breijo, Eduardo
Gil, Luis
author_sort Segui, María Jesús
collection PubMed
description The ionophore 1,4,7,10,13-penta(n-octyl)-1,4,7,10,13-pentaazacyclopentadecane (L(1)) was used for the development of miniaturised perchlorate-selective electrodes in thick-film technology. Different PVC membranes containing L(1) and the plasticizers o-nitrophenyl octyl ether (NPOE), dibutyl phthalate (DBP), bis(2-ethylhexyl)sebacate (DOS) and dibutyl sebacate (DBS) were prepared and placed on a graphite working electrode manufactured by using thick film serigraphic technology. The perchlorate selective electrode containing DBS as plasticizer showed a potentiometric Nernstian response of -57 mV per decade in a range of perchlorate concentration from 1 × 10(-4) to 1 × 10(-1) M with a detection limit of 5 × 10(-5) M. The ion selective electrodes containing DBP and NPOE as plasticizers exhibit a working range from 6.3 × 10(-5) to 1 × 10(-1) M and 7.4 × 10(-5) to 1 × 10(-1) M for perchlorate, respectively, with a detection limit of ca. 2.2 × 10(-5) M. For all three electrodes a response time of ca. 5 s was found. The prepared electrodes do not show appreciable decay of the slope for at least 25 days. Potentiometric selectivity coefficients (log K(pot)(ClO4)(-)(,X)(-)) with respect to the primary anion perchlorate were evaluated using the fixed interference method. These coefficients are of the order of 10(-1.7) or smaller, indicating the relatively poor interference of the different anions studied.
format Online
Article
Text
id pubmed-3872339
institution National Center for Biotechnology Information
language English
publishDate 2006
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-38723392013-12-26 An Ion-selective Electrode for Anion Perchlorate in Thick-film Technology Segui, María Jesús Lizondo-Sabater, Josefa Martínez-Máñez, Ramon Sancenon, Félix Soto, Juan Garcia-Breijo, Eduardo Gil, Luis Sensors (Basel) Full Paper The ionophore 1,4,7,10,13-penta(n-octyl)-1,4,7,10,13-pentaazacyclopentadecane (L(1)) was used for the development of miniaturised perchlorate-selective electrodes in thick-film technology. Different PVC membranes containing L(1) and the plasticizers o-nitrophenyl octyl ether (NPOE), dibutyl phthalate (DBP), bis(2-ethylhexyl)sebacate (DOS) and dibutyl sebacate (DBS) were prepared and placed on a graphite working electrode manufactured by using thick film serigraphic technology. The perchlorate selective electrode containing DBS as plasticizer showed a potentiometric Nernstian response of -57 mV per decade in a range of perchlorate concentration from 1 × 10(-4) to 1 × 10(-1) M with a detection limit of 5 × 10(-5) M. The ion selective electrodes containing DBP and NPOE as plasticizers exhibit a working range from 6.3 × 10(-5) to 1 × 10(-1) M and 7.4 × 10(-5) to 1 × 10(-1) M for perchlorate, respectively, with a detection limit of ca. 2.2 × 10(-5) M. For all three electrodes a response time of ca. 5 s was found. The prepared electrodes do not show appreciable decay of the slope for at least 25 days. Potentiometric selectivity coefficients (log K(pot)(ClO4)(-)(,X)(-)) with respect to the primary anion perchlorate were evaluated using the fixed interference method. These coefficients are of the order of 10(-1.7) or smaller, indicating the relatively poor interference of the different anions studied. Molecular Diversity Preservation International (MDPI) 2006-04-07 /pmc/articles/PMC3872339/ Text en © 2006 by MDPI (http://www.mdpi.org). Reproduction is permitted for noncommercial purposes.
spellingShingle Full Paper
Segui, María Jesús
Lizondo-Sabater, Josefa
Martínez-Máñez, Ramon
Sancenon, Félix
Soto, Juan
Garcia-Breijo, Eduardo
Gil, Luis
An Ion-selective Electrode for Anion Perchlorate in Thick-film Technology
title An Ion-selective Electrode for Anion Perchlorate in Thick-film Technology
title_full An Ion-selective Electrode for Anion Perchlorate in Thick-film Technology
title_fullStr An Ion-selective Electrode for Anion Perchlorate in Thick-film Technology
title_full_unstemmed An Ion-selective Electrode for Anion Perchlorate in Thick-film Technology
title_short An Ion-selective Electrode for Anion Perchlorate in Thick-film Technology
title_sort ion-selective electrode for anion perchlorate in thick-film technology
topic Full Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3872339/
work_keys_str_mv AT seguimariajesus anionselectiveelectrodeforanionperchlorateinthickfilmtechnology
AT lizondosabaterjosefa anionselectiveelectrodeforanionperchlorateinthickfilmtechnology
AT martinezmanezramon anionselectiveelectrodeforanionperchlorateinthickfilmtechnology
AT sancenonfelix anionselectiveelectrodeforanionperchlorateinthickfilmtechnology
AT sotojuan anionselectiveelectrodeforanionperchlorateinthickfilmtechnology
AT garciabreijoeduardo anionselectiveelectrodeforanionperchlorateinthickfilmtechnology
AT gilluis anionselectiveelectrodeforanionperchlorateinthickfilmtechnology
AT seguimariajesus ionselectiveelectrodeforanionperchlorateinthickfilmtechnology
AT lizondosabaterjosefa ionselectiveelectrodeforanionperchlorateinthickfilmtechnology
AT martinezmanezramon ionselectiveelectrodeforanionperchlorateinthickfilmtechnology
AT sancenonfelix ionselectiveelectrodeforanionperchlorateinthickfilmtechnology
AT sotojuan ionselectiveelectrodeforanionperchlorateinthickfilmtechnology
AT garciabreijoeduardo ionselectiveelectrodeforanionperchlorateinthickfilmtechnology
AT gilluis ionselectiveelectrodeforanionperchlorateinthickfilmtechnology