Response Behaviour of a Hydrogen Sensor Based on Ionic Conducting Polymer-metal Interfaces Prepared by the Chemical Reduction Method
A solid-state amperometric hydrogen sensor based on a protonated Nafion membrane and catalytic active electrode operating at room temperature was fabricated and tested. Ionic conducting polymer-metal electrode interfaces were prepared chemically by using the impregnation-reduction method. The polyme...