Ear surgery techniques results on hearing threshold improvement

BACKGROUND: Bone conduction (BC) threshold depression is not always by means of sensory neural hearing loss and sometimes it is an artifact caused by middle ear pathologies and ossicular chain problems. In this research, the influences of ear surgeries on bone conduction were evaluated. MATERIALS AN...

Descripción completa

Detalles Bibliográficos
Autores principales: Mokhtarinejad, Farhad, Pour, Saeed Soheili, Nilforoush, Mohammad Hussein, Sepehrnejad, Mahsa, Mirelahi, Susan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3872580/
https://www.ncbi.nlm.nih.gov/pubmed/24381615
_version_ 1782296982026452992
author Mokhtarinejad, Farhad
Pour, Saeed Soheili
Nilforoush, Mohammad Hussein
Sepehrnejad, Mahsa
Mirelahi, Susan
author_facet Mokhtarinejad, Farhad
Pour, Saeed Soheili
Nilforoush, Mohammad Hussein
Sepehrnejad, Mahsa
Mirelahi, Susan
author_sort Mokhtarinejad, Farhad
collection PubMed
description BACKGROUND: Bone conduction (BC) threshold depression is not always by means of sensory neural hearing loss and sometimes it is an artifact caused by middle ear pathologies and ossicular chain problems. In this research, the influences of ear surgeries on bone conduction were evaluated. MATERIALS AND METHODS: This study was conducted as a clinical trial study. The ear surgery performed on 83 patients classified in four categories: Stapedectomy, tympanomastoid surgery and ossicular reconstruction partially or totally; Partial Ossicular Replacement Prosthesis (PORP) and Total Ossicular Replacement Prosthesis (TORP). Bone conduction thresholds assessed in frequencies of 250, 500, 1000, 2000 and 4000 Hz pre and post the surgery. RESULTS: In stapedectomy group, the average of BC threshold in all frequencies improved approximately 6 dB in frequency of 2000 Hz. In tympanomastoid group, BC threshold in the frequency of 500, 1000 and 2000 Hz changed 4 dB (P-value < 0.05). Moreover, In the PORP group, 5 dB enhancement was seen in 1000 and 2000 Hz. In TORP group, the results confirmed that BC threshold improved in all frequencies especially at 4000 Hz about 6.5 dB. CONCLUSION: In according to results of this study, BC threshold shift was seen after several ear surgeries such as stapedectomy, tympanoplasty, PORP and TORP. The average of BC improvement was approximately 5 dB. It must be considered that BC depression might happen because of ossicular chain problems. Therefore; by resolving middle ear pathologies, the better BC threshold was obtained, the less hearing problems would be faced.
format Online
Article
Text
id pubmed-3872580
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-38725802013-12-31 Ear surgery techniques results on hearing threshold improvement Mokhtarinejad, Farhad Pour, Saeed Soheili Nilforoush, Mohammad Hussein Sepehrnejad, Mahsa Mirelahi, Susan J Res Med Sci Original Article BACKGROUND: Bone conduction (BC) threshold depression is not always by means of sensory neural hearing loss and sometimes it is an artifact caused by middle ear pathologies and ossicular chain problems. In this research, the influences of ear surgeries on bone conduction were evaluated. MATERIALS AND METHODS: This study was conducted as a clinical trial study. The ear surgery performed on 83 patients classified in four categories: Stapedectomy, tympanomastoid surgery and ossicular reconstruction partially or totally; Partial Ossicular Replacement Prosthesis (PORP) and Total Ossicular Replacement Prosthesis (TORP). Bone conduction thresholds assessed in frequencies of 250, 500, 1000, 2000 and 4000 Hz pre and post the surgery. RESULTS: In stapedectomy group, the average of BC threshold in all frequencies improved approximately 6 dB in frequency of 2000 Hz. In tympanomastoid group, BC threshold in the frequency of 500, 1000 and 2000 Hz changed 4 dB (P-value < 0.05). Moreover, In the PORP group, 5 dB enhancement was seen in 1000 and 2000 Hz. In TORP group, the results confirmed that BC threshold improved in all frequencies especially at 4000 Hz about 6.5 dB. CONCLUSION: In according to results of this study, BC threshold shift was seen after several ear surgeries such as stapedectomy, tympanoplasty, PORP and TORP. The average of BC improvement was approximately 5 dB. It must be considered that BC depression might happen because of ossicular chain problems. Therefore; by resolving middle ear pathologies, the better BC threshold was obtained, the less hearing problems would be faced. Medknow Publications & Media Pvt Ltd 2013-09 /pmc/articles/PMC3872580/ /pubmed/24381615 Text en Copyright: © Journal of Research in Medical Sciences http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Mokhtarinejad, Farhad
Pour, Saeed Soheili
Nilforoush, Mohammad Hussein
Sepehrnejad, Mahsa
Mirelahi, Susan
Ear surgery techniques results on hearing threshold improvement
title Ear surgery techniques results on hearing threshold improvement
title_full Ear surgery techniques results on hearing threshold improvement
title_fullStr Ear surgery techniques results on hearing threshold improvement
title_full_unstemmed Ear surgery techniques results on hearing threshold improvement
title_short Ear surgery techniques results on hearing threshold improvement
title_sort ear surgery techniques results on hearing threshold improvement
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3872580/
https://www.ncbi.nlm.nih.gov/pubmed/24381615
work_keys_str_mv AT mokhtarinejadfarhad earsurgerytechniquesresultsonhearingthresholdimprovement
AT poursaeedsoheili earsurgerytechniquesresultsonhearingthresholdimprovement
AT nilforoushmohammadhussein earsurgerytechniquesresultsonhearingthresholdimprovement
AT sepehrnejadmahsa earsurgerytechniquesresultsonhearingthresholdimprovement
AT mirelahisusan earsurgerytechniquesresultsonhearingthresholdimprovement