Cargando…

The “Coagulation Box” and a New Hemoglobin-Driven Algorithm for Bleeding Control in Patients with Severe Multiple Traumas

BACKGROUND: Extensive hemorrhage is the leading cause of death in the first few hours following multiple traumas. Therefore, early and aggressive treatment of clotting disorders could reduce mortality. Unfortunately, the availability of results from commonly performed blood coagulation studies are o...

Descripción completa

Detalles Bibliográficos
Autores principales: Hilbert, Peter, Hofmann, Gunther Olaf, Teichmann, Jörg, Struck, Manuel F., Stuttmann, Ralph
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Kowsar 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3876509/
https://www.ncbi.nlm.nih.gov/pubmed/24396782
http://dx.doi.org/10.5812/atr.10894
_version_ 1782297494523215872
author Hilbert, Peter
Hofmann, Gunther Olaf
Teichmann, Jörg
Struck, Manuel F.
Stuttmann, Ralph
author_facet Hilbert, Peter
Hofmann, Gunther Olaf
Teichmann, Jörg
Struck, Manuel F.
Stuttmann, Ralph
author_sort Hilbert, Peter
collection PubMed
description BACKGROUND: Extensive hemorrhage is the leading cause of death in the first few hours following multiple traumas. Therefore, early and aggressive treatment of clotting disorders could reduce mortality. Unfortunately, the availability of results from commonly performed blood coagulation studies are often delayed whereas hemoglobin (Hb) levels are quickly available. OBJECTIVES: In this study, we evaluated the use of initial hemoglobin (Hb) levels as a guide line for the initial treatment of clotting disorders in multiple trauma patients. PATIENTS AND METHODS: We have developed an Hb-driven algorithm to initiate the initial clotting therapy. The algorithm contains three different steps for aggressive clotting therapy depending on the first Hb value measured in the shock trauma room, (SR) and utilizes fibrinogen, prothrombin complex concentrate (PCC), factor VIIa, tranexamic acid and desmopressin. The above-mentioned drugs were stored in a special “coagulation box” in the hospital pharmacy, and this box could be immediately brought to the SR or operating room (OR) upon request. Despite the use of clotting factors, transfusions using red blood cells (RBC) and fresh frozen plasma (FFP) were performed at an RBC-to-FFP ratio of 2:1 to 1:1. RESULTS: Over a 12-month investigation period, 123 severe multiple trauma patients needing intensive care therapy were admitted to our trauma center (mean age 48 years, mean ISS (injury severity score) 30). Fourteen (11%) patients died; 25 (mean age 51.5 years, mean ISS 53) of the 123 patients were treated using the “coagulation box,” and 17 patients required massive transfusions. Patients treated with the “coagulation box” required an average dose of 16.3 RBC and 12.9 FFP, whereas 17 of the 25 patients required an average dose of 3.6 platelet packs. According to the algorithm, 25 patients received fibrinogen (average dose of 8.25 g), 24 (96%) received PCC (3000 IU.), 14 (56%) received desmopressin (36.6 µg), 13 (52%) received tranexamic acid (2.88 g), and 11 (44%) received factor VIIa (3.7 mg). The clotting parameters markedly improved between SR admission and ICU admission. Of the 25 patients, 16 (64%) survived. The revised injury severity classification (RISC) predicted a survival rate of 41%, which corresponds to a standardized mortality ratio (SMR) of 0.62, which implies a higher survival rate than predicted. CONCLUSIONS: An Hb-driven algorithm, in combination with the “coagulation box” and the early use of clotting factors, could be a simple and effective tool for improving coagulopathy in multiple trauma patients.
format Online
Article
Text
id pubmed-3876509
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Kowsar
record_format MEDLINE/PubMed
spelling pubmed-38765092014-01-06 The “Coagulation Box” and a New Hemoglobin-Driven Algorithm for Bleeding Control in Patients with Severe Multiple Traumas Hilbert, Peter Hofmann, Gunther Olaf Teichmann, Jörg Struck, Manuel F. Stuttmann, Ralph Arch Trauma Res Research Article BACKGROUND: Extensive hemorrhage is the leading cause of death in the first few hours following multiple traumas. Therefore, early and aggressive treatment of clotting disorders could reduce mortality. Unfortunately, the availability of results from commonly performed blood coagulation studies are often delayed whereas hemoglobin (Hb) levels are quickly available. OBJECTIVES: In this study, we evaluated the use of initial hemoglobin (Hb) levels as a guide line for the initial treatment of clotting disorders in multiple trauma patients. PATIENTS AND METHODS: We have developed an Hb-driven algorithm to initiate the initial clotting therapy. The algorithm contains three different steps for aggressive clotting therapy depending on the first Hb value measured in the shock trauma room, (SR) and utilizes fibrinogen, prothrombin complex concentrate (PCC), factor VIIa, tranexamic acid and desmopressin. The above-mentioned drugs were stored in a special “coagulation box” in the hospital pharmacy, and this box could be immediately brought to the SR or operating room (OR) upon request. Despite the use of clotting factors, transfusions using red blood cells (RBC) and fresh frozen plasma (FFP) were performed at an RBC-to-FFP ratio of 2:1 to 1:1. RESULTS: Over a 12-month investigation period, 123 severe multiple trauma patients needing intensive care therapy were admitted to our trauma center (mean age 48 years, mean ISS (injury severity score) 30). Fourteen (11%) patients died; 25 (mean age 51.5 years, mean ISS 53) of the 123 patients were treated using the “coagulation box,” and 17 patients required massive transfusions. Patients treated with the “coagulation box” required an average dose of 16.3 RBC and 12.9 FFP, whereas 17 of the 25 patients required an average dose of 3.6 platelet packs. According to the algorithm, 25 patients received fibrinogen (average dose of 8.25 g), 24 (96%) received PCC (3000 IU.), 14 (56%) received desmopressin (36.6 µg), 13 (52%) received tranexamic acid (2.88 g), and 11 (44%) received factor VIIa (3.7 mg). The clotting parameters markedly improved between SR admission and ICU admission. Of the 25 patients, 16 (64%) survived. The revised injury severity classification (RISC) predicted a survival rate of 41%, which corresponds to a standardized mortality ratio (SMR) of 0.62, which implies a higher survival rate than predicted. CONCLUSIONS: An Hb-driven algorithm, in combination with the “coagulation box” and the early use of clotting factors, could be a simple and effective tool for improving coagulopathy in multiple trauma patients. Kowsar 2013-06-01 2013 /pmc/articles/PMC3876509/ /pubmed/24396782 http://dx.doi.org/10.5812/atr.10894 Text en Copyright © 2013, Kashan University of Medical Sciences http://creativecommons.org/licenses/by/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Hilbert, Peter
Hofmann, Gunther Olaf
Teichmann, Jörg
Struck, Manuel F.
Stuttmann, Ralph
The “Coagulation Box” and a New Hemoglobin-Driven Algorithm for Bleeding Control in Patients with Severe Multiple Traumas
title The “Coagulation Box” and a New Hemoglobin-Driven Algorithm for Bleeding Control in Patients with Severe Multiple Traumas
title_full The “Coagulation Box” and a New Hemoglobin-Driven Algorithm for Bleeding Control in Patients with Severe Multiple Traumas
title_fullStr The “Coagulation Box” and a New Hemoglobin-Driven Algorithm for Bleeding Control in Patients with Severe Multiple Traumas
title_full_unstemmed The “Coagulation Box” and a New Hemoglobin-Driven Algorithm for Bleeding Control in Patients with Severe Multiple Traumas
title_short The “Coagulation Box” and a New Hemoglobin-Driven Algorithm for Bleeding Control in Patients with Severe Multiple Traumas
title_sort “coagulation box” and a new hemoglobin-driven algorithm for bleeding control in patients with severe multiple traumas
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3876509/
https://www.ncbi.nlm.nih.gov/pubmed/24396782
http://dx.doi.org/10.5812/atr.10894
work_keys_str_mv AT hilbertpeter thecoagulationboxandanewhemoglobindrivenalgorithmforbleedingcontrolinpatientswithseveremultipletraumas
AT hofmannguntherolaf thecoagulationboxandanewhemoglobindrivenalgorithmforbleedingcontrolinpatientswithseveremultipletraumas
AT teichmannjorg thecoagulationboxandanewhemoglobindrivenalgorithmforbleedingcontrolinpatientswithseveremultipletraumas
AT struckmanuelf thecoagulationboxandanewhemoglobindrivenalgorithmforbleedingcontrolinpatientswithseveremultipletraumas
AT stuttmannralph thecoagulationboxandanewhemoglobindrivenalgorithmforbleedingcontrolinpatientswithseveremultipletraumas
AT hilbertpeter coagulationboxandanewhemoglobindrivenalgorithmforbleedingcontrolinpatientswithseveremultipletraumas
AT hofmannguntherolaf coagulationboxandanewhemoglobindrivenalgorithmforbleedingcontrolinpatientswithseveremultipletraumas
AT teichmannjorg coagulationboxandanewhemoglobindrivenalgorithmforbleedingcontrolinpatientswithseveremultipletraumas
AT struckmanuelf coagulationboxandanewhemoglobindrivenalgorithmforbleedingcontrolinpatientswithseveremultipletraumas
AT stuttmannralph coagulationboxandanewhemoglobindrivenalgorithmforbleedingcontrolinpatientswithseveremultipletraumas