Cargando…
Development of Novel Radiogallium-Labeled Bone Imaging Agents Using Oligo-Aspartic Acid Peptides as Carriers
(68)Ga (T (1/2) = 68 min, a generator-produced nuclide) has great potential as a radionuclide for clinical positron emission tomography (PET). Because poly-glutamic and poly-aspartic acids have high affinity for hydroxyapatite, to develop new bone targeting (68)Ga-labeled bone imaging agents for PET...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3877283/ https://www.ncbi.nlm.nih.gov/pubmed/24391942 http://dx.doi.org/10.1371/journal.pone.0084335 |
Sumario: | (68)Ga (T (1/2) = 68 min, a generator-produced nuclide) has great potential as a radionuclide for clinical positron emission tomography (PET). Because poly-glutamic and poly-aspartic acids have high affinity for hydroxyapatite, to develop new bone targeting (68)Ga-labeled bone imaging agents for PET, we used 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) as a chelating site and conjugated aspartic acid peptides of varying lengths. Subsequently, we compared Ga complexes, Ga-DOTA-(Asp)(n) (n = 2, 5, 8, 11, or 14) with easy-to-handle (67)Ga, with the previously described (67)Ga-DOTA complex conjugated bisphosphonate, (67)Ga-DOTA-Bn-SCN-HBP. After synthesizing DOTA-(Asp)(n) by a Fmoc-based solid-phase method, complexes were formed with (67)Ga, resulting in (67)Ga-DOTA-(Asp)(n) with a radiochemical purity of over 95% after HPLC purification. In hydroxyapatite binding assays, the binding rate of (67)Ga-DOTA-(Asp)(n) increased with the increase in the length of the conjugated aspartate peptide. Moreover, in biodistribution experiments, (67)Ga-DOTA-(Asp)(8), (67)Ga-DOTA-(Asp)(11), and (67)Ga-DOTA-(Asp)(14) showed high accumulation in bone (10.5±1.5, 15.1±2.6, and 12.8±1.7% ID/g, respectively) but were barely observed in other tissues at 60 min after injection. Although bone accumulation of (67)Ga-DOTA-(Asp)(n) was lower than that of (67)Ga-DOTA-Bn-SCN-HBP, blood clearance of (67)Ga-DOTA-(Asp)(n) was more rapid. Accordingly, the bone/blood ratios of (67)Ga-DOTA-(Asp)(11) and (67)Ga-DOTA-(Asp)(14) were comparable with those of (67)Ga-DOTA-Bn-SCN-HBP. In conclusion, these data provide useful insights into the drug design of (68)Ga-PET tracers for the diagnosis of bone disorders, such as bone metastases. |
---|