Cargando…

Application of Ni-Ti Alloy connector for the treatment of comminuted coronal plane supracondylar-condylar femoral fractures: a retrospective review of 21 patients

BACKGROUND: Our preliminary retrospective study assessed outcomes after the use of Ni-Ti arched shape-memory connector (ASC) combined with partially threaded cancellous screws (PTCS) to repair coronal plane supracondylar-condylar femoral fractures. METHODS: Twenty-one patients (16 men and 5 women) w...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Yuntong, Zhao, Xue, Tang, Yang, Zhang, Chuncai, Xu, Shuogui, Xie, Yang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3878495/
https://www.ncbi.nlm.nih.gov/pubmed/24341860
http://dx.doi.org/10.1186/1471-2474-14-355
_version_ 1782297816140349440
author Zhang, Yuntong
Zhao, Xue
Tang, Yang
Zhang, Chuncai
Xu, Shuogui
Xie, Yang
author_facet Zhang, Yuntong
Zhao, Xue
Tang, Yang
Zhang, Chuncai
Xu, Shuogui
Xie, Yang
author_sort Zhang, Yuntong
collection PubMed
description BACKGROUND: Our preliminary retrospective study assessed outcomes after the use of Ni-Ti arched shape-memory connector (ASC) combined with partially threaded cancellous screws (PTCS) to repair coronal plane supracondylar-condylar femoral fractures. METHODS: Twenty-one patients (16 men and 5 women) with a mean age of 34.1 years (range, 28 to 44 years) with coronal plane supracondylar and condylar fractures of the distal femur were included in this study. Each patient underwent open reduction and internal fixation using the ASC and PTCS. Active functional exercises with restricted weight bearing were initiated the first postoperative day. A gradual increase in weight bearing status and range of motion was permitted and subjects progressed to full weight bearing by 8 weeks. Surgical time, blood loss, postoperative knee range of motion, American Knee Society Scores (KSS), and postoperative complications were assessed. RESULTS: The mean surgical time was 75 mins (range, 45 to 100 mins) and average blood loss was 105 ml (range, 35 to 130 ml). Mean follow-up was 65 months (range, 22 to 90 months). No subjects demonstrated evidence of osteonecrosis or arthritis at the final follow-up. The mean KSS was excellent (≥85) in 8 subjects, good (70-84) in 11 subjects, and fair (60-69) in 2 subjects. The mean active range of motion of knee flexion at final follow-up was 100 degrees (range, 85 to 110 degrees). CONCLUSIONS: ASC combined with PTCS can serve as an effective means for managing comminuted femoral fractures that extend from the condyle to the supracondylar region. However, further prospective comparative studies and biomechanical analyses are needed to evaluate long-term outcomes using these materials.
format Online
Article
Text
id pubmed-3878495
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-38784952014-01-03 Application of Ni-Ti Alloy connector for the treatment of comminuted coronal plane supracondylar-condylar femoral fractures: a retrospective review of 21 patients Zhang, Yuntong Zhao, Xue Tang, Yang Zhang, Chuncai Xu, Shuogui Xie, Yang BMC Musculoskelet Disord Technical Advance BACKGROUND: Our preliminary retrospective study assessed outcomes after the use of Ni-Ti arched shape-memory connector (ASC) combined with partially threaded cancellous screws (PTCS) to repair coronal plane supracondylar-condylar femoral fractures. METHODS: Twenty-one patients (16 men and 5 women) with a mean age of 34.1 years (range, 28 to 44 years) with coronal plane supracondylar and condylar fractures of the distal femur were included in this study. Each patient underwent open reduction and internal fixation using the ASC and PTCS. Active functional exercises with restricted weight bearing were initiated the first postoperative day. A gradual increase in weight bearing status and range of motion was permitted and subjects progressed to full weight bearing by 8 weeks. Surgical time, blood loss, postoperative knee range of motion, American Knee Society Scores (KSS), and postoperative complications were assessed. RESULTS: The mean surgical time was 75 mins (range, 45 to 100 mins) and average blood loss was 105 ml (range, 35 to 130 ml). Mean follow-up was 65 months (range, 22 to 90 months). No subjects demonstrated evidence of osteonecrosis or arthritis at the final follow-up. The mean KSS was excellent (≥85) in 8 subjects, good (70-84) in 11 subjects, and fair (60-69) in 2 subjects. The mean active range of motion of knee flexion at final follow-up was 100 degrees (range, 85 to 110 degrees). CONCLUSIONS: ASC combined with PTCS can serve as an effective means for managing comminuted femoral fractures that extend from the condyle to the supracondylar region. However, further prospective comparative studies and biomechanical analyses are needed to evaluate long-term outcomes using these materials. BioMed Central 2013-12-17 /pmc/articles/PMC3878495/ /pubmed/24341860 http://dx.doi.org/10.1186/1471-2474-14-355 Text en Copyright © 2013 Zhang et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Advance
Zhang, Yuntong
Zhao, Xue
Tang, Yang
Zhang, Chuncai
Xu, Shuogui
Xie, Yang
Application of Ni-Ti Alloy connector for the treatment of comminuted coronal plane supracondylar-condylar femoral fractures: a retrospective review of 21 patients
title Application of Ni-Ti Alloy connector for the treatment of comminuted coronal plane supracondylar-condylar femoral fractures: a retrospective review of 21 patients
title_full Application of Ni-Ti Alloy connector for the treatment of comminuted coronal plane supracondylar-condylar femoral fractures: a retrospective review of 21 patients
title_fullStr Application of Ni-Ti Alloy connector for the treatment of comminuted coronal plane supracondylar-condylar femoral fractures: a retrospective review of 21 patients
title_full_unstemmed Application of Ni-Ti Alloy connector for the treatment of comminuted coronal plane supracondylar-condylar femoral fractures: a retrospective review of 21 patients
title_short Application of Ni-Ti Alloy connector for the treatment of comminuted coronal plane supracondylar-condylar femoral fractures: a retrospective review of 21 patients
title_sort application of ni-ti alloy connector for the treatment of comminuted coronal plane supracondylar-condylar femoral fractures: a retrospective review of 21 patients
topic Technical Advance
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3878495/
https://www.ncbi.nlm.nih.gov/pubmed/24341860
http://dx.doi.org/10.1186/1471-2474-14-355
work_keys_str_mv AT zhangyuntong applicationofnitialloyconnectorforthetreatmentofcomminutedcoronalplanesupracondylarcondylarfemoralfracturesaretrospectivereviewof21patients
AT zhaoxue applicationofnitialloyconnectorforthetreatmentofcomminutedcoronalplanesupracondylarcondylarfemoralfracturesaretrospectivereviewof21patients
AT tangyang applicationofnitialloyconnectorforthetreatmentofcomminutedcoronalplanesupracondylarcondylarfemoralfracturesaretrospectivereviewof21patients
AT zhangchuncai applicationofnitialloyconnectorforthetreatmentofcomminutedcoronalplanesupracondylarcondylarfemoralfracturesaretrospectivereviewof21patients
AT xushuogui applicationofnitialloyconnectorforthetreatmentofcomminutedcoronalplanesupracondylarcondylarfemoralfracturesaretrospectivereviewof21patients
AT xieyang applicationofnitialloyconnectorforthetreatmentofcomminutedcoronalplanesupracondylarcondylarfemoralfracturesaretrospectivereviewof21patients