Cargando…
A Systematic Method of Interconnection Optimization for Dense-Array Concentrator Photovoltaic System
This paper presents a new systematic approach to analyze all possible array configurations in order to determine the most optimal dense-array configuration for concentrator photovoltaic (CPV) systems. The proposed method is fast, simple, reasonably accurate, and very useful as a preliminary study be...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3878601/ https://www.ncbi.nlm.nih.gov/pubmed/24453823 http://dx.doi.org/10.1155/2013/275169 |
_version_ | 1782297839198535680 |
---|---|
author | Siaw, Fei-Lu Chong, Kok-Keong |
author_facet | Siaw, Fei-Lu Chong, Kok-Keong |
author_sort | Siaw, Fei-Lu |
collection | PubMed |
description | This paper presents a new systematic approach to analyze all possible array configurations in order to determine the most optimal dense-array configuration for concentrator photovoltaic (CPV) systems. The proposed method is fast, simple, reasonably accurate, and very useful as a preliminary study before constructing a dense-array CPV panel. Using measured flux distribution data, each CPV cells' voltage and current values at three critical points which are at short-circuit, open-circuit, and maximum power point are determined. From there, an algorithm groups the cells into basic modules. The next step is I-V curve prediction, to find the maximum output power of each array configuration. As a case study, twenty different I-V predictions are made for a prototype of nonimaging planar concentrator, and the array configuration that yields the highest output power is determined. The result is then verified by assembling and testing of an actual dense-array on the prototype. It was found that the I-V curve closely resembles simulated I-V prediction, and measured maximum output power varies by only 1.34%. |
format | Online Article Text |
id | pubmed-3878601 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-38786012014-01-19 A Systematic Method of Interconnection Optimization for Dense-Array Concentrator Photovoltaic System Siaw, Fei-Lu Chong, Kok-Keong ScientificWorldJournal Research Article This paper presents a new systematic approach to analyze all possible array configurations in order to determine the most optimal dense-array configuration for concentrator photovoltaic (CPV) systems. The proposed method is fast, simple, reasonably accurate, and very useful as a preliminary study before constructing a dense-array CPV panel. Using measured flux distribution data, each CPV cells' voltage and current values at three critical points which are at short-circuit, open-circuit, and maximum power point are determined. From there, an algorithm groups the cells into basic modules. The next step is I-V curve prediction, to find the maximum output power of each array configuration. As a case study, twenty different I-V predictions are made for a prototype of nonimaging planar concentrator, and the array configuration that yields the highest output power is determined. The result is then verified by assembling and testing of an actual dense-array on the prototype. It was found that the I-V curve closely resembles simulated I-V prediction, and measured maximum output power varies by only 1.34%. Hindawi Publishing Corporation 2013-12-17 /pmc/articles/PMC3878601/ /pubmed/24453823 http://dx.doi.org/10.1155/2013/275169 Text en Copyright © 2013 F.-L. Siaw and K.-K. Chong. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Siaw, Fei-Lu Chong, Kok-Keong A Systematic Method of Interconnection Optimization for Dense-Array Concentrator Photovoltaic System |
title | A Systematic Method of Interconnection Optimization for Dense-Array Concentrator Photovoltaic System |
title_full | A Systematic Method of Interconnection Optimization for Dense-Array Concentrator Photovoltaic System |
title_fullStr | A Systematic Method of Interconnection Optimization for Dense-Array Concentrator Photovoltaic System |
title_full_unstemmed | A Systematic Method of Interconnection Optimization for Dense-Array Concentrator Photovoltaic System |
title_short | A Systematic Method of Interconnection Optimization for Dense-Array Concentrator Photovoltaic System |
title_sort | systematic method of interconnection optimization for dense-array concentrator photovoltaic system |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3878601/ https://www.ncbi.nlm.nih.gov/pubmed/24453823 http://dx.doi.org/10.1155/2013/275169 |
work_keys_str_mv | AT siawfeilu asystematicmethodofinterconnectionoptimizationfordensearrayconcentratorphotovoltaicsystem AT chongkokkeong asystematicmethodofinterconnectionoptimizationfordensearrayconcentratorphotovoltaicsystem AT siawfeilu systematicmethodofinterconnectionoptimizationfordensearrayconcentratorphotovoltaicsystem AT chongkokkeong systematicmethodofinterconnectionoptimizationfordensearrayconcentratorphotovoltaicsystem |