Cargando…

Effects of positioning on radiographic measurements of ankle morphology: a computerized tomography-based simulation study

BACKGROUND: Measurements of the morphology of the ankle joint, performed mostly for surgical planning of total ankle arthroplasty and for collecting data for total ankle prosthesis design, are often made on planar radiographs, and therefore can be very sensitive to the positioning of the joint durin...

Descripción completa

Detalles Bibliográficos
Autores principales: Kuo, Chien-Chung, Lu, Hsuan-Lun, Lu, Tung-Wu, Lin, Cheng-Chung, Leardini, Alberto, Kuo, Mei-Ying, Hsu, Horng-Chaung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3879435/
https://www.ncbi.nlm.nih.gov/pubmed/24359413
http://dx.doi.org/10.1186/1475-925X-12-131
_version_ 1782297984893976576
author Kuo, Chien-Chung
Lu, Hsuan-Lun
Lu, Tung-Wu
Lin, Cheng-Chung
Leardini, Alberto
Kuo, Mei-Ying
Hsu, Horng-Chaung
author_facet Kuo, Chien-Chung
Lu, Hsuan-Lun
Lu, Tung-Wu
Lin, Cheng-Chung
Leardini, Alberto
Kuo, Mei-Ying
Hsu, Horng-Chaung
author_sort Kuo, Chien-Chung
collection PubMed
description BACKGROUND: Measurements of the morphology of the ankle joint, performed mostly for surgical planning of total ankle arthroplasty and for collecting data for total ankle prosthesis design, are often made on planar radiographs, and therefore can be very sensitive to the positioning of the joint during imaging. The current study aimed to compare ankle morphological measurements using CT-generated 2D images with gold standard values obtained from 3D CT data; to determine the sensitivity of the 2D measurements to mal-positioning of the ankle during imaging; and to quantify the repeatability of the 2D measurements under simulated positioning conditions involving random errors. METHOD: Fifty-eight cadaveric ankles fixed in the neutral joint position (standard pose) were CT scanned, and the data were used to simulate lateral and frontal radiographs under various positioning conditions using digitally reconstructed radiographs (DRR). RESULTS AND DISCUSSION: In the standard pose for imaging, most ankle morphometric parameters measured using 2D images were highly correlated (R > 0.8) to the gold standard values defined by the 3D CT data. For measurements made on the lateral views, the only parameters sensitive to rotational pose errors were longitudinal distances between the most anterior and the most posterior points of the tibial mortise and the tibial profile, which have important implications for determining the optimal cutting level of the bone during arthroplasty. Measurements of the trochlea tali width on the frontal views underestimated the standard values by up to 31.2%, with only a moderate reliability, suggesting that pre-surgical evaluations based on the trochlea tali width should be made with caution in order to avoid inappropriate selection of prosthesis sizes. CONCLUSIONS: While highly correlated with 3D morphological measurements, some 2D measurements were affected by the bone poses in space during imaging, which may affect surgical decision-making in total ankle arthroplasty, including the amount of bone resection and the selection of the implant sizes. The linear regression equations for the relationship between 2D and 3D measurements will be helpful for correcting the errors in 2D morphometric measurements for clinical applications.
format Online
Article
Text
id pubmed-3879435
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-38794352014-01-04 Effects of positioning on radiographic measurements of ankle morphology: a computerized tomography-based simulation study Kuo, Chien-Chung Lu, Hsuan-Lun Lu, Tung-Wu Lin, Cheng-Chung Leardini, Alberto Kuo, Mei-Ying Hsu, Horng-Chaung Biomed Eng Online Research BACKGROUND: Measurements of the morphology of the ankle joint, performed mostly for surgical planning of total ankle arthroplasty and for collecting data for total ankle prosthesis design, are often made on planar radiographs, and therefore can be very sensitive to the positioning of the joint during imaging. The current study aimed to compare ankle morphological measurements using CT-generated 2D images with gold standard values obtained from 3D CT data; to determine the sensitivity of the 2D measurements to mal-positioning of the ankle during imaging; and to quantify the repeatability of the 2D measurements under simulated positioning conditions involving random errors. METHOD: Fifty-eight cadaveric ankles fixed in the neutral joint position (standard pose) were CT scanned, and the data were used to simulate lateral and frontal radiographs under various positioning conditions using digitally reconstructed radiographs (DRR). RESULTS AND DISCUSSION: In the standard pose for imaging, most ankle morphometric parameters measured using 2D images were highly correlated (R > 0.8) to the gold standard values defined by the 3D CT data. For measurements made on the lateral views, the only parameters sensitive to rotational pose errors were longitudinal distances between the most anterior and the most posterior points of the tibial mortise and the tibial profile, which have important implications for determining the optimal cutting level of the bone during arthroplasty. Measurements of the trochlea tali width on the frontal views underestimated the standard values by up to 31.2%, with only a moderate reliability, suggesting that pre-surgical evaluations based on the trochlea tali width should be made with caution in order to avoid inappropriate selection of prosthesis sizes. CONCLUSIONS: While highly correlated with 3D morphological measurements, some 2D measurements were affected by the bone poses in space during imaging, which may affect surgical decision-making in total ankle arthroplasty, including the amount of bone resection and the selection of the implant sizes. The linear regression equations for the relationship between 2D and 3D measurements will be helpful for correcting the errors in 2D morphometric measurements for clinical applications. BioMed Central 2013-12-20 /pmc/articles/PMC3879435/ /pubmed/24359413 http://dx.doi.org/10.1186/1475-925X-12-131 Text en Copyright © 2013 Kuo et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Kuo, Chien-Chung
Lu, Hsuan-Lun
Lu, Tung-Wu
Lin, Cheng-Chung
Leardini, Alberto
Kuo, Mei-Ying
Hsu, Horng-Chaung
Effects of positioning on radiographic measurements of ankle morphology: a computerized tomography-based simulation study
title Effects of positioning on radiographic measurements of ankle morphology: a computerized tomography-based simulation study
title_full Effects of positioning on radiographic measurements of ankle morphology: a computerized tomography-based simulation study
title_fullStr Effects of positioning on radiographic measurements of ankle morphology: a computerized tomography-based simulation study
title_full_unstemmed Effects of positioning on radiographic measurements of ankle morphology: a computerized tomography-based simulation study
title_short Effects of positioning on radiographic measurements of ankle morphology: a computerized tomography-based simulation study
title_sort effects of positioning on radiographic measurements of ankle morphology: a computerized tomography-based simulation study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3879435/
https://www.ncbi.nlm.nih.gov/pubmed/24359413
http://dx.doi.org/10.1186/1475-925X-12-131
work_keys_str_mv AT kuochienchung effectsofpositioningonradiographicmeasurementsofanklemorphologyacomputerizedtomographybasedsimulationstudy
AT luhsuanlun effectsofpositioningonradiographicmeasurementsofanklemorphologyacomputerizedtomographybasedsimulationstudy
AT lutungwu effectsofpositioningonradiographicmeasurementsofanklemorphologyacomputerizedtomographybasedsimulationstudy
AT linchengchung effectsofpositioningonradiographicmeasurementsofanklemorphologyacomputerizedtomographybasedsimulationstudy
AT leardinialberto effectsofpositioningonradiographicmeasurementsofanklemorphologyacomputerizedtomographybasedsimulationstudy
AT kuomeiying effectsofpositioningonradiographicmeasurementsofanklemorphologyacomputerizedtomographybasedsimulationstudy
AT hsuhorngchaung effectsofpositioningonradiographicmeasurementsofanklemorphologyacomputerizedtomographybasedsimulationstudy