Cargando…
Gated F-18 FDG PET for Assessment of Left Ventricular Volumes and Ejection Fraction Using QGS and 4D-MSPECT in Patients with Heart Failure: A Comparison with Cardiac MRI
PURPOSE: Ventricular function is a powerful predictor of survival in patients with heart failure (HF). However, studies characterizing gated F-18 FDG PET for the assessment of the cardiac function are rare. The aim of this study was to prospectively compare gated F-18 FDG PET and cardiac MRI for the...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3880258/ https://www.ncbi.nlm.nih.gov/pubmed/24404123 http://dx.doi.org/10.1371/journal.pone.0080227 |
_version_ | 1782298056748695552 |
---|---|
author | Li, Yan Wang, Li Zhao, Shi-Hua He, Zuo-Xiang Wang, Dao-Yu Guo, Feng Fang, Wei Yang, Min-Fu |
author_facet | Li, Yan Wang, Li Zhao, Shi-Hua He, Zuo-Xiang Wang, Dao-Yu Guo, Feng Fang, Wei Yang, Min-Fu |
author_sort | Li, Yan |
collection | PubMed |
description | PURPOSE: Ventricular function is a powerful predictor of survival in patients with heart failure (HF). However, studies characterizing gated F-18 FDG PET for the assessment of the cardiac function are rare. The aim of this study was to prospectively compare gated F-18 FDG PET and cardiac MRI for the assessment of ventricular volume and ejection fraction (EF) in patients with HF. METHODS: Eighty-nine patients with diagnosed HF who underwent both gated F-18 FDG PET/CT and cardiac MRI within 3 days were included in the analysis. Left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV), and EF were obtained from gated F-18 FDG PET/CT using the Quantitative Gated SPECT (QGS) and 4D-MSPECT software. RESULTS: LV EDV and LV ESV measured by QGS were significantly lower than those measured by cardiac MRI (both P<0.0001). In contrast, the corresponding values for LV EDV for 4D-MSPECT were comparable, and LV ESV was underestimated with borderline significance compared with cardiac MRI (P = 0.047). LV EF measured by QGS and cardiac MRI showed no significant differences, whereas the corresponding values for 4D-MSPECT were lower than for cardiac MRI (P<0.0001). The correlations of LV EDV, LV ESV, and LV EF between gated F-18 FDG PET/CT and cardiac MRI were excellent for both QGS (r = 0.92, 0.92, and 0.76, respectively) and 4D-MSPECT (r = 0.93, 0.94, and 0.75, respectively). However, Bland-Altman analysis revealed a significant systemic error, where LV EDV (−27.9±37.0 mL) and ESV (−18.6±33.8 mL) were underestimated by QGS. CONCLUSION: Despite the observation that gated F-18 FDG PET/CT were well correlated with cardiac MRI for assessing LV function, variation was observed between the two imaging modalities, and so these imaging techniques should not be used interchangeably. |
format | Online Article Text |
id | pubmed-3880258 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-38802582014-01-08 Gated F-18 FDG PET for Assessment of Left Ventricular Volumes and Ejection Fraction Using QGS and 4D-MSPECT in Patients with Heart Failure: A Comparison with Cardiac MRI Li, Yan Wang, Li Zhao, Shi-Hua He, Zuo-Xiang Wang, Dao-Yu Guo, Feng Fang, Wei Yang, Min-Fu PLoS One Research Article PURPOSE: Ventricular function is a powerful predictor of survival in patients with heart failure (HF). However, studies characterizing gated F-18 FDG PET for the assessment of the cardiac function are rare. The aim of this study was to prospectively compare gated F-18 FDG PET and cardiac MRI for the assessment of ventricular volume and ejection fraction (EF) in patients with HF. METHODS: Eighty-nine patients with diagnosed HF who underwent both gated F-18 FDG PET/CT and cardiac MRI within 3 days were included in the analysis. Left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV), and EF were obtained from gated F-18 FDG PET/CT using the Quantitative Gated SPECT (QGS) and 4D-MSPECT software. RESULTS: LV EDV and LV ESV measured by QGS were significantly lower than those measured by cardiac MRI (both P<0.0001). In contrast, the corresponding values for LV EDV for 4D-MSPECT were comparable, and LV ESV was underestimated with borderline significance compared with cardiac MRI (P = 0.047). LV EF measured by QGS and cardiac MRI showed no significant differences, whereas the corresponding values for 4D-MSPECT were lower than for cardiac MRI (P<0.0001). The correlations of LV EDV, LV ESV, and LV EF between gated F-18 FDG PET/CT and cardiac MRI were excellent for both QGS (r = 0.92, 0.92, and 0.76, respectively) and 4D-MSPECT (r = 0.93, 0.94, and 0.75, respectively). However, Bland-Altman analysis revealed a significant systemic error, where LV EDV (−27.9±37.0 mL) and ESV (−18.6±33.8 mL) were underestimated by QGS. CONCLUSION: Despite the observation that gated F-18 FDG PET/CT were well correlated with cardiac MRI for assessing LV function, variation was observed between the two imaging modalities, and so these imaging techniques should not be used interchangeably. Public Library of Science 2014-01-03 /pmc/articles/PMC3880258/ /pubmed/24404123 http://dx.doi.org/10.1371/journal.pone.0080227 Text en © 2014 Li et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Li, Yan Wang, Li Zhao, Shi-Hua He, Zuo-Xiang Wang, Dao-Yu Guo, Feng Fang, Wei Yang, Min-Fu Gated F-18 FDG PET for Assessment of Left Ventricular Volumes and Ejection Fraction Using QGS and 4D-MSPECT in Patients with Heart Failure: A Comparison with Cardiac MRI |
title | Gated F-18 FDG PET for Assessment of Left Ventricular Volumes and Ejection Fraction Using QGS and 4D-MSPECT in Patients with Heart Failure: A Comparison with Cardiac MRI |
title_full | Gated F-18 FDG PET for Assessment of Left Ventricular Volumes and Ejection Fraction Using QGS and 4D-MSPECT in Patients with Heart Failure: A Comparison with Cardiac MRI |
title_fullStr | Gated F-18 FDG PET for Assessment of Left Ventricular Volumes and Ejection Fraction Using QGS and 4D-MSPECT in Patients with Heart Failure: A Comparison with Cardiac MRI |
title_full_unstemmed | Gated F-18 FDG PET for Assessment of Left Ventricular Volumes and Ejection Fraction Using QGS and 4D-MSPECT in Patients with Heart Failure: A Comparison with Cardiac MRI |
title_short | Gated F-18 FDG PET for Assessment of Left Ventricular Volumes and Ejection Fraction Using QGS and 4D-MSPECT in Patients with Heart Failure: A Comparison with Cardiac MRI |
title_sort | gated f-18 fdg pet for assessment of left ventricular volumes and ejection fraction using qgs and 4d-mspect in patients with heart failure: a comparison with cardiac mri |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3880258/ https://www.ncbi.nlm.nih.gov/pubmed/24404123 http://dx.doi.org/10.1371/journal.pone.0080227 |
work_keys_str_mv | AT liyan gatedf18fdgpetforassessmentofleftventricularvolumesandejectionfractionusingqgsand4dmspectinpatientswithheartfailureacomparisonwithcardiacmri AT wangli gatedf18fdgpetforassessmentofleftventricularvolumesandejectionfractionusingqgsand4dmspectinpatientswithheartfailureacomparisonwithcardiacmri AT zhaoshihua gatedf18fdgpetforassessmentofleftventricularvolumesandejectionfractionusingqgsand4dmspectinpatientswithheartfailureacomparisonwithcardiacmri AT hezuoxiang gatedf18fdgpetforassessmentofleftventricularvolumesandejectionfractionusingqgsand4dmspectinpatientswithheartfailureacomparisonwithcardiacmri AT wangdaoyu gatedf18fdgpetforassessmentofleftventricularvolumesandejectionfractionusingqgsand4dmspectinpatientswithheartfailureacomparisonwithcardiacmri AT guofeng gatedf18fdgpetforassessmentofleftventricularvolumesandejectionfractionusingqgsand4dmspectinpatientswithheartfailureacomparisonwithcardiacmri AT fangwei gatedf18fdgpetforassessmentofleftventricularvolumesandejectionfractionusingqgsand4dmspectinpatientswithheartfailureacomparisonwithcardiacmri AT yangminfu gatedf18fdgpetforassessmentofleftventricularvolumesandejectionfractionusingqgsand4dmspectinpatientswithheartfailureacomparisonwithcardiacmri |