Cargando…
Wear of double crown systems - electroplated vs. casted female part
OBJECTIVES: The wear of telescopic crowns is a common problem often reducing the patient's satisfaction with the denture and resulting in a renewal of the denture. The study aims to compare the wear behavior of conical crowns using electroplated copings (group E) with standard telescopic crowns...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Faculdade de Odontologia de Bauru da Universidade de São
Paulo
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3881770/ https://www.ncbi.nlm.nih.gov/pubmed/22858708 http://dx.doi.org/10.1590/S1678-77572012000300015 |
_version_ | 1782298260207042560 |
---|---|
author | BAYER, Stefan KRAUS, Dominik KEILIG, Ludger GÖLZ, Lina STARK, Helmut ENKLING, Norbert |
author_facet | BAYER, Stefan KRAUS, Dominik KEILIG, Ludger GÖLZ, Lina STARK, Helmut ENKLING, Norbert |
author_sort | BAYER, Stefan |
collection | PubMed |
description | OBJECTIVES: The wear of telescopic crowns is a common problem often reducing the patient's satisfaction with the denture and resulting in a renewal of the denture. The study aims to compare the wear behavior of conical crowns using electroplated copings (group E) with standard telescopic crowns with cast female parts (group C). MATERIAL AND METHODS: 10 conical crowns were milled for each group of a cast gold alloy. The specimen of group E had a conicity of 2º. The cast secondary crowns of group C had a 0º design. The electroplated coping was established by direct electroforming. An apparatus accomplishing 10,000 wear cycles performed the wear test. The retentive forces and the correlating distance during insertion and separation were measured. The wear test was separated in a start phase, an initial wear phase and the long term wear period. The retention force value and the force-distance integral of the first 0.33 mm of each cycle were calculated. RESULTS: The retentive forces were significantly higher for group E and the integrals were significantly lower for this group except the integral at cycle 10,000. The changes of retention force and integral did not differ significantly between both groups in all phases. The change of the integrals as well as the integral at the particular cycles showed higher interquartile distances for group C. CONCLUSIONS: Within the limitations of this study the tested conical crowns showed clinically acceptable retentive properties. The values reached a range comparable to retentive elements tested in recent literature. The values of group C showed higher ranges. The force measured for group E was significantly higher than for group C but the integrals showed an opposite tendency. The results indicate that an exclusive analysis of the force is not sufficient as the integral is not equivalent to the force although it describes the retentive property of the system in a better way than the force over a distance is described. Both systems seem to be suitable for clinical practice. |
format | Online Article Text |
id | pubmed-3881770 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Faculdade de Odontologia de Bauru da Universidade de São
Paulo |
record_format | MEDLINE/PubMed |
spelling | pubmed-38817702014-01-08 Wear of double crown systems - electroplated vs. casted female part BAYER, Stefan KRAUS, Dominik KEILIG, Ludger GÖLZ, Lina STARK, Helmut ENKLING, Norbert J Appl Oral Sci Original Articles OBJECTIVES: The wear of telescopic crowns is a common problem often reducing the patient's satisfaction with the denture and resulting in a renewal of the denture. The study aims to compare the wear behavior of conical crowns using electroplated copings (group E) with standard telescopic crowns with cast female parts (group C). MATERIAL AND METHODS: 10 conical crowns were milled for each group of a cast gold alloy. The specimen of group E had a conicity of 2º. The cast secondary crowns of group C had a 0º design. The electroplated coping was established by direct electroforming. An apparatus accomplishing 10,000 wear cycles performed the wear test. The retentive forces and the correlating distance during insertion and separation were measured. The wear test was separated in a start phase, an initial wear phase and the long term wear period. The retention force value and the force-distance integral of the first 0.33 mm of each cycle were calculated. RESULTS: The retentive forces were significantly higher for group E and the integrals were significantly lower for this group except the integral at cycle 10,000. The changes of retention force and integral did not differ significantly between both groups in all phases. The change of the integrals as well as the integral at the particular cycles showed higher interquartile distances for group C. CONCLUSIONS: Within the limitations of this study the tested conical crowns showed clinically acceptable retentive properties. The values reached a range comparable to retentive elements tested in recent literature. The values of group C showed higher ranges. The force measured for group E was significantly higher than for group C but the integrals showed an opposite tendency. The results indicate that an exclusive analysis of the force is not sufficient as the integral is not equivalent to the force although it describes the retentive property of the system in a better way than the force over a distance is described. Both systems seem to be suitable for clinical practice. Faculdade de Odontologia de Bauru da Universidade de São Paulo 2012 /pmc/articles/PMC3881770/ /pubmed/22858708 http://dx.doi.org/10.1590/S1678-77572012000300015 Text en http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Articles BAYER, Stefan KRAUS, Dominik KEILIG, Ludger GÖLZ, Lina STARK, Helmut ENKLING, Norbert Wear of double crown systems - electroplated vs. casted female part |
title | Wear of double crown systems - electroplated vs. casted female
part |
title_full | Wear of double crown systems - electroplated vs. casted female
part |
title_fullStr | Wear of double crown systems - electroplated vs. casted female
part |
title_full_unstemmed | Wear of double crown systems - electroplated vs. casted female
part |
title_short | Wear of double crown systems - electroplated vs. casted female
part |
title_sort | wear of double crown systems - electroplated vs. casted female
part |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3881770/ https://www.ncbi.nlm.nih.gov/pubmed/22858708 http://dx.doi.org/10.1590/S1678-77572012000300015 |
work_keys_str_mv | AT bayerstefan wearofdoublecrownsystemselectroplatedvscastedfemalepart AT krausdominik wearofdoublecrownsystemselectroplatedvscastedfemalepart AT keiligludger wearofdoublecrownsystemselectroplatedvscastedfemalepart AT golzlina wearofdoublecrownsystemselectroplatedvscastedfemalepart AT starkhelmut wearofdoublecrownsystemselectroplatedvscastedfemalepart AT enklingnorbert wearofdoublecrownsystemselectroplatedvscastedfemalepart |