Effect of pre-flaring and file size on the accuracy of two electronic apex locators
OBJECTIVE: This ex vivo study evaluated the effect of pre-flaring and file size on the accuracy of the Root ZX and Novapex electronic apex locators (EALs). MATERIAL AND METHODS: The actual working length (WL) was set 1 mm short of the apical foramen in the palatal root canals of 24 extracted maxilla...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Faculdade de Odontologia de Bauru da Universidade de São
Paulo
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3881801/ https://www.ncbi.nlm.nih.gov/pubmed/23138740 http://dx.doi.org/10.1590/S1678-77572012000500008 |
_version_ | 1782298267213627392 |
---|---|
author | BRITO-JÚNIOR, Manoel CAMILO, Carla Cristina MOREIRA-JÚNIOR, Gil PECORA, Jesus Djalma SOUSA-NETO, Manoel Damião |
author_facet | BRITO-JÚNIOR, Manoel CAMILO, Carla Cristina MOREIRA-JÚNIOR, Gil PECORA, Jesus Djalma SOUSA-NETO, Manoel Damião |
author_sort | BRITO-JÚNIOR, Manoel |
collection | PubMed |
description | OBJECTIVE: This ex vivo study evaluated the effect of pre-flaring and file size on the accuracy of the Root ZX and Novapex electronic apex locators (EALs). MATERIAL AND METHODS: The actual working length (WL) was set 1 mm short of the apical foramen in the palatal root canals of 24 extracted maxillary molars. The teeth were embedded in an alginate mold, and two examiners performed the electronic measurements using #10, #15, and #20 K-files. The files were inserted into the root canals until the "0.0" or ''APEX'' signals were observed on the LED or display screens for the Novapex and Root ZX, respectively, retracting to the 1.0 mark. The measurements were repeated after the pre-flaring using the S1 and SX Pro-Taper instruments. Two measurements were performed for each condition and the means were used. Intra-class correlation coefficients (ICCs) were calculated to verify the intra- and inter-examiner agreement. The mean differences between the WL and electronic length values were analyzed by the three-way ANOVA test (p<0.05). RESULTS: ICCs were high (>0.8) and the results demonstrated a similar accuracy for both EALs (p>0.05). Statistically significant accurate measurements were verified in the pre-flared canals, except for the Novapex using a #20 K-file. CONCLUSIONS: The tested EALs showed acceptable accuracy, whereas the pre-flaring procedure revealed a more significant effect than the used file size. |
format | Online Article Text |
id | pubmed-3881801 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Faculdade de Odontologia de Bauru da Universidade de São
Paulo |
record_format | MEDLINE/PubMed |
spelling | pubmed-38818012014-01-08 Effect of pre-flaring and file size on the accuracy of two electronic apex locators BRITO-JÚNIOR, Manoel CAMILO, Carla Cristina MOREIRA-JÚNIOR, Gil PECORA, Jesus Djalma SOUSA-NETO, Manoel Damião J Appl Oral Sci Original Articles OBJECTIVE: This ex vivo study evaluated the effect of pre-flaring and file size on the accuracy of the Root ZX and Novapex electronic apex locators (EALs). MATERIAL AND METHODS: The actual working length (WL) was set 1 mm short of the apical foramen in the palatal root canals of 24 extracted maxillary molars. The teeth were embedded in an alginate mold, and two examiners performed the electronic measurements using #10, #15, and #20 K-files. The files were inserted into the root canals until the "0.0" or ''APEX'' signals were observed on the LED or display screens for the Novapex and Root ZX, respectively, retracting to the 1.0 mark. The measurements were repeated after the pre-flaring using the S1 and SX Pro-Taper instruments. Two measurements were performed for each condition and the means were used. Intra-class correlation coefficients (ICCs) were calculated to verify the intra- and inter-examiner agreement. The mean differences between the WL and electronic length values were analyzed by the three-way ANOVA test (p<0.05). RESULTS: ICCs were high (>0.8) and the results demonstrated a similar accuracy for both EALs (p>0.05). Statistically significant accurate measurements were verified in the pre-flared canals, except for the Novapex using a #20 K-file. CONCLUSIONS: The tested EALs showed acceptable accuracy, whereas the pre-flaring procedure revealed a more significant effect than the used file size. Faculdade de Odontologia de Bauru da Universidade de São Paulo 2012 /pmc/articles/PMC3881801/ /pubmed/23138740 http://dx.doi.org/10.1590/S1678-77572012000500008 Text en http://creativecommons.org/licenses/by-nc/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Articles BRITO-JÚNIOR, Manoel CAMILO, Carla Cristina MOREIRA-JÚNIOR, Gil PECORA, Jesus Djalma SOUSA-NETO, Manoel Damião Effect of pre-flaring and file size on the accuracy of two electronic apex locators |
title | Effect of pre-flaring and file size on the accuracy of two electronic
apex locators |
title_full | Effect of pre-flaring and file size on the accuracy of two electronic
apex locators |
title_fullStr | Effect of pre-flaring and file size on the accuracy of two electronic
apex locators |
title_full_unstemmed | Effect of pre-flaring and file size on the accuracy of two electronic
apex locators |
title_short | Effect of pre-flaring and file size on the accuracy of two electronic
apex locators |
title_sort | effect of pre-flaring and file size on the accuracy of two electronic
apex locators |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3881801/ https://www.ncbi.nlm.nih.gov/pubmed/23138740 http://dx.doi.org/10.1590/S1678-77572012000500008 |
work_keys_str_mv | AT britojuniormanoel effectofpreflaringandfilesizeontheaccuracyoftwoelectronicapexlocators AT camilocarlacristina effectofpreflaringandfilesizeontheaccuracyoftwoelectronicapexlocators AT moreirajuniorgil effectofpreflaringandfilesizeontheaccuracyoftwoelectronicapexlocators AT pecorajesusdjalma effectofpreflaringandfilesizeontheaccuracyoftwoelectronicapexlocators AT sousanetomanoeldamiao effectofpreflaringandfilesizeontheaccuracyoftwoelectronicapexlocators |