Cargando…

A simple three-dimensional stent for proper placement of mini-implant

BACKGROUND: This paper deals with the fabrication of a three-dimensional stent which is simple in design but provides an accurate placement of a mini-implant in three planes of space, namely, sagittal (root proximity), vertical (attached gingiva/alveolar mucosa) and transverse (angulation). FINDINGS...

Descripción completa

Detalles Bibliográficos
Autor principal: Felicita, A Sumathi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3883515/
https://www.ncbi.nlm.nih.gov/pubmed/24326158
http://dx.doi.org/10.1186/2196-1042-14-45
_version_ 1782298466135834624
author Felicita, A Sumathi
author_facet Felicita, A Sumathi
author_sort Felicita, A Sumathi
collection PubMed
description BACKGROUND: This paper deals with the fabrication of a three-dimensional stent which is simple in design but provides an accurate placement of a mini-implant in three planes of space, namely, sagittal (root proximity), vertical (attached gingiva/alveolar mucosa) and transverse (angulation). FINDINGS: The stent is made of 0.018 × 0.025 in. stainless steel archwire which consists of a ‘u loop’ angulated at 20°, a vertical limb, a horizontal limb and a stop. The angulation of the ‘u’ helps in the placement of the mini-implant at 70° to the long axis of the tooth. The vertical height is determined such that the mini-implant is placed at the mucogingival junction. The mini-implant is placed with the aid of the stent, and its angulation and proximity to the adjacent roots are checked with a cone beam computed tomography image. The cone beam computed tomography image showed the mini-implant at an angle of 70° to the long axis of the tooth. There is no contact between mini-implant and the roots of the adjacent teeth. CONCLUSION: This stent is simple, easy to fabricate, cost-effective, and provides ease of insertion/removal, and three-dimensional orientation of the mini-implant.
format Online
Article
Text
id pubmed-3883515
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Springer
record_format MEDLINE/PubMed
spelling pubmed-38835152014-01-08 A simple three-dimensional stent for proper placement of mini-implant Felicita, A Sumathi Prog Orthod Short Report BACKGROUND: This paper deals with the fabrication of a three-dimensional stent which is simple in design but provides an accurate placement of a mini-implant in three planes of space, namely, sagittal (root proximity), vertical (attached gingiva/alveolar mucosa) and transverse (angulation). FINDINGS: The stent is made of 0.018 × 0.025 in. stainless steel archwire which consists of a ‘u loop’ angulated at 20°, a vertical limb, a horizontal limb and a stop. The angulation of the ‘u’ helps in the placement of the mini-implant at 70° to the long axis of the tooth. The vertical height is determined such that the mini-implant is placed at the mucogingival junction. The mini-implant is placed with the aid of the stent, and its angulation and proximity to the adjacent roots are checked with a cone beam computed tomography image. The cone beam computed tomography image showed the mini-implant at an angle of 70° to the long axis of the tooth. There is no contact between mini-implant and the roots of the adjacent teeth. CONCLUSION: This stent is simple, easy to fabricate, cost-effective, and provides ease of insertion/removal, and three-dimensional orientation of the mini-implant. Springer 2013-11-12 /pmc/articles/PMC3883515/ /pubmed/24326158 http://dx.doi.org/10.1186/2196-1042-14-45 Text en Copyright © 2013 Felicita; licensee Springer. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Short Report
Felicita, A Sumathi
A simple three-dimensional stent for proper placement of mini-implant
title A simple three-dimensional stent for proper placement of mini-implant
title_full A simple three-dimensional stent for proper placement of mini-implant
title_fullStr A simple three-dimensional stent for proper placement of mini-implant
title_full_unstemmed A simple three-dimensional stent for proper placement of mini-implant
title_short A simple three-dimensional stent for proper placement of mini-implant
title_sort simple three-dimensional stent for proper placement of mini-implant
topic Short Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3883515/
https://www.ncbi.nlm.nih.gov/pubmed/24326158
http://dx.doi.org/10.1186/2196-1042-14-45
work_keys_str_mv AT felicitaasumathi asimplethreedimensionalstentforproperplacementofminiimplant
AT felicitaasumathi simplethreedimensionalstentforproperplacementofminiimplant