Revisiting QRS Detection Methodologies for Portable, Wearable, Battery-Operated, and Wireless ECG Systems
Cardiovascular diseases are the number one cause of death worldwide. Currently, portable battery-operated systems such as mobile phones with wireless ECG sensors have the potential to be used in continuous cardiac function assessment that can be easily integrated into daily life. These portable poin...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3883654/ https://www.ncbi.nlm.nih.gov/pubmed/24409290 http://dx.doi.org/10.1371/journal.pone.0084018 |
_version_ | 1782298483143737344 |
---|---|
author | Elgendi, Mohamed Eskofier, Björn Dokos, Socrates Abbott, Derek |
author_facet | Elgendi, Mohamed Eskofier, Björn Dokos, Socrates Abbott, Derek |
author_sort | Elgendi, Mohamed |
collection | PubMed |
description | Cardiovascular diseases are the number one cause of death worldwide. Currently, portable battery-operated systems such as mobile phones with wireless ECG sensors have the potential to be used in continuous cardiac function assessment that can be easily integrated into daily life. These portable point-of-care diagnostic systems can therefore help unveil and treat cardiovascular diseases. The basis for ECG analysis is a robust detection of the prominent QRS complex, as well as other ECG signal characteristics. However, it is not clear from the literature which ECG analysis algorithms are suited for an implementation on a mobile device. We investigate current QRS detection algorithms based on three assessment criteria: 1) robustness to noise, 2) parameter choice, and 3) numerical efficiency, in order to target a universal fast-robust detector. Furthermore, existing QRS detection algorithms may provide an acceptable solution only on small segments of ECG signals, within a certain amplitude range, or amid particular types of arrhythmia and/or noise. These issues are discussed in the context of a comparison with the most conventional algorithms, followed by future recommendations for developing reliable QRS detection schemes suitable for implementation on battery-operated mobile devices. |
format | Online Article Text |
id | pubmed-3883654 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-38836542014-01-09 Revisiting QRS Detection Methodologies for Portable, Wearable, Battery-Operated, and Wireless ECG Systems Elgendi, Mohamed Eskofier, Björn Dokos, Socrates Abbott, Derek PLoS One Research Article Cardiovascular diseases are the number one cause of death worldwide. Currently, portable battery-operated systems such as mobile phones with wireless ECG sensors have the potential to be used in continuous cardiac function assessment that can be easily integrated into daily life. These portable point-of-care diagnostic systems can therefore help unveil and treat cardiovascular diseases. The basis for ECG analysis is a robust detection of the prominent QRS complex, as well as other ECG signal characteristics. However, it is not clear from the literature which ECG analysis algorithms are suited for an implementation on a mobile device. We investigate current QRS detection algorithms based on three assessment criteria: 1) robustness to noise, 2) parameter choice, and 3) numerical efficiency, in order to target a universal fast-robust detector. Furthermore, existing QRS detection algorithms may provide an acceptable solution only on small segments of ECG signals, within a certain amplitude range, or amid particular types of arrhythmia and/or noise. These issues are discussed in the context of a comparison with the most conventional algorithms, followed by future recommendations for developing reliable QRS detection schemes suitable for implementation on battery-operated mobile devices. Public Library of Science 2014-01-07 /pmc/articles/PMC3883654/ /pubmed/24409290 http://dx.doi.org/10.1371/journal.pone.0084018 Text en © 2014 Elgendi et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Elgendi, Mohamed Eskofier, Björn Dokos, Socrates Abbott, Derek Revisiting QRS Detection Methodologies for Portable, Wearable, Battery-Operated, and Wireless ECG Systems |
title | Revisiting QRS Detection Methodologies for Portable, Wearable, Battery-Operated, and Wireless ECG Systems |
title_full | Revisiting QRS Detection Methodologies for Portable, Wearable, Battery-Operated, and Wireless ECG Systems |
title_fullStr | Revisiting QRS Detection Methodologies for Portable, Wearable, Battery-Operated, and Wireless ECG Systems |
title_full_unstemmed | Revisiting QRS Detection Methodologies for Portable, Wearable, Battery-Operated, and Wireless ECG Systems |
title_short | Revisiting QRS Detection Methodologies for Portable, Wearable, Battery-Operated, and Wireless ECG Systems |
title_sort | revisiting qrs detection methodologies for portable, wearable, battery-operated, and wireless ecg systems |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3883654/ https://www.ncbi.nlm.nih.gov/pubmed/24409290 http://dx.doi.org/10.1371/journal.pone.0084018 |
work_keys_str_mv | AT elgendimohamed revisitingqrsdetectionmethodologiesforportablewearablebatteryoperatedandwirelessecgsystems AT eskofierbjorn revisitingqrsdetectionmethodologiesforportablewearablebatteryoperatedandwirelessecgsystems AT dokossocrates revisitingqrsdetectionmethodologiesforportablewearablebatteryoperatedandwirelessecgsystems AT abbottderek revisitingqrsdetectionmethodologiesforportablewearablebatteryoperatedandwirelessecgsystems |