VO(2) and VCO(2) variabilities through indirect calorimetry instrumentation

The aim of this paper is to understand how to measure the VO(2) and VCO(2) variabilities in indirect calorimetry (IC) since we believe they can explain the high variation in the resting energy expenditure (REE) estimation. We propose that variabilities should be separately measured from the VO(2) an...

Descripción completa

Detalles Bibliográficos
Autores principales: Cadena-Méndez, Miguel, Escalante-Ramírez, Boris, Azpiroz-Leehan, Joaquín, Infante-Vázquez, Oscar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3884081/
https://www.ncbi.nlm.nih.gov/pubmed/24422180
http://dx.doi.org/10.1186/2193-1801-2-688
_version_ 1782298513649958912
author Cadena-Méndez, Miguel
Escalante-Ramírez, Boris
Azpiroz-Leehan, Joaquín
Infante-Vázquez, Oscar
author_facet Cadena-Méndez, Miguel
Escalante-Ramírez, Boris
Azpiroz-Leehan, Joaquín
Infante-Vázquez, Oscar
author_sort Cadena-Méndez, Miguel
collection PubMed
description The aim of this paper is to understand how to measure the VO(2) and VCO(2) variabilities in indirect calorimetry (IC) since we believe they can explain the high variation in the resting energy expenditure (REE) estimation. We propose that variabilities should be separately measured from the VO(2) and VCO(2) averages to understand technological differences among metabolic monitors when they estimate the REE. To prove this hypothesis the mixing chamber (MC) and the breath-by-breath (BbB) techniques measured the VO(2) and VCO(2) averages and their variabilities. Variances and power spectrum energies in the 0–0.5 Hertz band were measured to establish technique differences in steady and non-steady state. A hybrid calorimeter with both IC techniques studied a population of 15 volunteers that underwent the clino-orthostatic maneuver in order to produce the two physiological stages. The results showed that inter-individual VO(2) and VCO(2) variabilities measured as variances were negligible using the MC while variabilities measured as spectral energies using the BbB underwent 71 and 56% (p < 0.05), increase respectively. Additionally, the energy analysis showed an unexpected cyclic rhythm at 0.025 Hertz only during the orthostatic stage, which is new physiological information, not reported previusly. The VO(2) and VCO(2) inter-individual averages increased to 63 and 39% by the MC (p < 0.05) and 32 and 40% using the BbB (p < 0.1), respectively, without noticeable statistical differences among techniques. The conclusions are: (a) metabolic monitors should simultaneously include the MC and the BbB techniques to correctly interpret the steady or non-steady state variabilities effect in the REE estimation, (b) the MC is the appropriate technique to compute averages since it behaves as a low-pass filter that minimizes variances, (c) the BbB is the ideal technique to measure the variabilities since it can work as a high-pass filter to generate discrete time series able to accomplish spectral analysis, and (d) the new physiological information in the VO(2) and VCO(2) variabilities can help to understand why metabolic monitors with dissimilar IC techniques give different results in the REE estimation.
format Online
Article
Text
id pubmed-3884081
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-38840812014-01-13 VO(2) and VCO(2) variabilities through indirect calorimetry instrumentation Cadena-Méndez, Miguel Escalante-Ramírez, Boris Azpiroz-Leehan, Joaquín Infante-Vázquez, Oscar Springerplus Research The aim of this paper is to understand how to measure the VO(2) and VCO(2) variabilities in indirect calorimetry (IC) since we believe they can explain the high variation in the resting energy expenditure (REE) estimation. We propose that variabilities should be separately measured from the VO(2) and VCO(2) averages to understand technological differences among metabolic monitors when they estimate the REE. To prove this hypothesis the mixing chamber (MC) and the breath-by-breath (BbB) techniques measured the VO(2) and VCO(2) averages and their variabilities. Variances and power spectrum energies in the 0–0.5 Hertz band were measured to establish technique differences in steady and non-steady state. A hybrid calorimeter with both IC techniques studied a population of 15 volunteers that underwent the clino-orthostatic maneuver in order to produce the two physiological stages. The results showed that inter-individual VO(2) and VCO(2) variabilities measured as variances were negligible using the MC while variabilities measured as spectral energies using the BbB underwent 71 and 56% (p < 0.05), increase respectively. Additionally, the energy analysis showed an unexpected cyclic rhythm at 0.025 Hertz only during the orthostatic stage, which is new physiological information, not reported previusly. The VO(2) and VCO(2) inter-individual averages increased to 63 and 39% by the MC (p < 0.05) and 32 and 40% using the BbB (p < 0.1), respectively, without noticeable statistical differences among techniques. The conclusions are: (a) metabolic monitors should simultaneously include the MC and the BbB techniques to correctly interpret the steady or non-steady state variabilities effect in the REE estimation, (b) the MC is the appropriate technique to compute averages since it behaves as a low-pass filter that minimizes variances, (c) the BbB is the ideal technique to measure the variabilities since it can work as a high-pass filter to generate discrete time series able to accomplish spectral analysis, and (d) the new physiological information in the VO(2) and VCO(2) variabilities can help to understand why metabolic monitors with dissimilar IC techniques give different results in the REE estimation. Springer International Publishing 2013-12-23 /pmc/articles/PMC3884081/ /pubmed/24422180 http://dx.doi.org/10.1186/2193-1801-2-688 Text en © Cadena-Méndez et al.; licensee Springer. 2013 This article is published under license to BioMed Central Ltd. This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Cadena-Méndez, Miguel
Escalante-Ramírez, Boris
Azpiroz-Leehan, Joaquín
Infante-Vázquez, Oscar
VO(2) and VCO(2) variabilities through indirect calorimetry instrumentation
title VO(2) and VCO(2) variabilities through indirect calorimetry instrumentation
title_full VO(2) and VCO(2) variabilities through indirect calorimetry instrumentation
title_fullStr VO(2) and VCO(2) variabilities through indirect calorimetry instrumentation
title_full_unstemmed VO(2) and VCO(2) variabilities through indirect calorimetry instrumentation
title_short VO(2) and VCO(2) variabilities through indirect calorimetry instrumentation
title_sort vo(2) and vco(2) variabilities through indirect calorimetry instrumentation
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3884081/
https://www.ncbi.nlm.nih.gov/pubmed/24422180
http://dx.doi.org/10.1186/2193-1801-2-688
work_keys_str_mv AT cadenamendezmiguel vo2andvco2variabilitiesthroughindirectcalorimetryinstrumentation
AT escalanteramirezboris vo2andvco2variabilitiesthroughindirectcalorimetryinstrumentation
AT azpirozleehanjoaquin vo2andvco2variabilitiesthroughindirectcalorimetryinstrumentation
AT infantevazquezoscar vo2andvco2variabilitiesthroughindirectcalorimetryinstrumentation