The Influence of Tube Potential on Periodontal Bone Level Measurements and Subjective Image Quality Using a Digital Photostimulable Storage Phosphor Sensor

OBJECTIVES: The purpose of the present study was to determine the measurement accuracy and subjective image quality for periodontal disease diagnosis when using two X-ray tube voltages with a digital photostimulable storage phosphor sensor. MATERIAL AND METHODS: A digital photostimulable storage pho...

Descripción completa

Detalles Bibliográficos
Autores principales: Vandenberghe, Bart, Jacobs, Reinhilde
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Stilus Optimus 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3886041/
https://www.ncbi.nlm.nih.gov/pubmed/24421961
http://dx.doi.org/10.5037/jomr.2010.1105
_version_ 1782478849986002944
author Vandenberghe, Bart
Jacobs, Reinhilde
author_facet Vandenberghe, Bart
Jacobs, Reinhilde
author_sort Vandenberghe, Bart
collection PubMed
description OBJECTIVES: The purpose of the present study was to determine the measurement accuracy and subjective image quality for periodontal disease diagnosis when using two X-ray tube voltages with a digital photostimulable storage phosphor sensor. MATERIAL AND METHODS: A digital photostimulable storage phosphor (PSP) sensor (Vistascan) and a multipulse X-ray generator (Prostyle Intra) with two tube voltages were used in this study. The front, premolar and molar region of two adult human cadaver skulls jaws were imaged using the X-ray tube at 63 kV and 70 kV, both at 8 mA and decreasing exposure times (160 ms, 120 ms and 80 ms). A standardized exposure protocol containing waxed occlusal keys and an aiming device ensured proper and reproducible beam alignment. Three observers assessed the digital radiographs for 31 selected periodontal bone loss sites. Radiographic measurements were compared to physical measurements (Standard). Subjective ratings of lamina dura, crater defect and furcation involvement visibility, contrast perception and bone quality were also performed. RESULTS: Multiple regression equation of the variables kV and exposure time demonstrated no significant difference for the periodontal bone level measurements (P > 0.05). In 90.3% and 96.7% of the measurements for 70 kV and 63 kV respectively, deviation was within 1 mm. The subjective ratings produced similar findings in terms of image quality for both tube voltages and the three exposure times. CONCLUSIONS: The results of the present study revealed that tube voltages of 63 kV and 70 kV provided similar accuracy and image quality for periodontal disease diagnosis.
format Online
Article
Text
id pubmed-3886041
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Stilus Optimus
record_format MEDLINE/PubMed
spelling pubmed-38860412014-01-13 The Influence of Tube Potential on Periodontal Bone Level Measurements and Subjective Image Quality Using a Digital Photostimulable Storage Phosphor Sensor Vandenberghe, Bart Jacobs, Reinhilde J Oral Maxillofac Res Original Paper OBJECTIVES: The purpose of the present study was to determine the measurement accuracy and subjective image quality for periodontal disease diagnosis when using two X-ray tube voltages with a digital photostimulable storage phosphor sensor. MATERIAL AND METHODS: A digital photostimulable storage phosphor (PSP) sensor (Vistascan) and a multipulse X-ray generator (Prostyle Intra) with two tube voltages were used in this study. The front, premolar and molar region of two adult human cadaver skulls jaws were imaged using the X-ray tube at 63 kV and 70 kV, both at 8 mA and decreasing exposure times (160 ms, 120 ms and 80 ms). A standardized exposure protocol containing waxed occlusal keys and an aiming device ensured proper and reproducible beam alignment. Three observers assessed the digital radiographs for 31 selected periodontal bone loss sites. Radiographic measurements were compared to physical measurements (Standard). Subjective ratings of lamina dura, crater defect and furcation involvement visibility, contrast perception and bone quality were also performed. RESULTS: Multiple regression equation of the variables kV and exposure time demonstrated no significant difference for the periodontal bone level measurements (P > 0.05). In 90.3% and 96.7% of the measurements for 70 kV and 63 kV respectively, deviation was within 1 mm. The subjective ratings produced similar findings in terms of image quality for both tube voltages and the three exposure times. CONCLUSIONS: The results of the present study revealed that tube voltages of 63 kV and 70 kV provided similar accuracy and image quality for periodontal disease diagnosis. Stilus Optimus 2010-04-01 /pmc/articles/PMC3886041/ /pubmed/24421961 http://dx.doi.org/10.5037/jomr.2010.1105 Text en Copyright © Vandenberghe B, Jacobs R. Published in the JOURNAL OF ORAL & MAXILLOFACIAL RESEARCH (http://www.ejomr.org), 1 April 2010. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article, first published in the JOURNAL OF ORAL & MAXILLOFACIAL RESEARCH, distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work and is properly cited. The copyright, license information and link to the original publication on http://www.ejomr.org must be included.
spellingShingle Original Paper
Vandenberghe, Bart
Jacobs, Reinhilde
The Influence of Tube Potential on Periodontal Bone Level Measurements and Subjective Image Quality Using a Digital Photostimulable Storage Phosphor Sensor
title The Influence of Tube Potential on Periodontal Bone Level Measurements and Subjective Image Quality Using a Digital Photostimulable Storage Phosphor Sensor
title_full The Influence of Tube Potential on Periodontal Bone Level Measurements and Subjective Image Quality Using a Digital Photostimulable Storage Phosphor Sensor
title_fullStr The Influence of Tube Potential on Periodontal Bone Level Measurements and Subjective Image Quality Using a Digital Photostimulable Storage Phosphor Sensor
title_full_unstemmed The Influence of Tube Potential on Periodontal Bone Level Measurements and Subjective Image Quality Using a Digital Photostimulable Storage Phosphor Sensor
title_short The Influence of Tube Potential on Periodontal Bone Level Measurements and Subjective Image Quality Using a Digital Photostimulable Storage Phosphor Sensor
title_sort influence of tube potential on periodontal bone level measurements and subjective image quality using a digital photostimulable storage phosphor sensor
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3886041/
https://www.ncbi.nlm.nih.gov/pubmed/24421961
http://dx.doi.org/10.5037/jomr.2010.1105
work_keys_str_mv AT vandenberghebart theinfluenceoftubepotentialonperiodontalbonelevelmeasurementsandsubjectiveimagequalityusingadigitalphotostimulablestoragephosphorsensor
AT jacobsreinhilde theinfluenceoftubepotentialonperiodontalbonelevelmeasurementsandsubjectiveimagequalityusingadigitalphotostimulablestoragephosphorsensor
AT vandenberghebart influenceoftubepotentialonperiodontalbonelevelmeasurementsandsubjectiveimagequalityusingadigitalphotostimulablestoragephosphorsensor
AT jacobsreinhilde influenceoftubepotentialonperiodontalbonelevelmeasurementsandsubjectiveimagequalityusingadigitalphotostimulablestoragephosphorsensor