An Investigation of Calibration Phantoms for CT Scanners with Tube Voltage Modulation

The effects of calibration phantoms on the correction results of the empirical artifacts correction method (ECCU) for the case of tube modulation were investigated. To improve the validity of the ECCU method, the effect of the geometry parameter of a typical single-material calibration phantom (wate...

Descripción completa

Detalles Bibliográficos
Autores principales: Zou, Jing, Hu, Xiaodong, Lv, Hanyu, Hu, Xiaotang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3886221/
https://www.ncbi.nlm.nih.gov/pubmed/24454334
http://dx.doi.org/10.1155/2013/563571
_version_ 1782478871151509504
author Zou, Jing
Hu, Xiaodong
Lv, Hanyu
Hu, Xiaotang
author_facet Zou, Jing
Hu, Xiaodong
Lv, Hanyu
Hu, Xiaotang
author_sort Zou, Jing
collection PubMed
description The effects of calibration phantoms on the correction results of the empirical artifacts correction method (ECCU) for the case of tube modulation were investigated. To improve the validity of the ECCU method, the effect of the geometry parameter of a typical single-material calibration phantom (water calibration phantom) on the ECCU algorithm was investigated. Dual-material calibration phantoms (such as water-bone calibration phantom), geometry arrangement, and the area-ratio of dual-material calibration phantoms were also studied. Preliminary results implied that, to assure the effectiveness of the ECCU algorithm, the polychromatic projections of calibration phantoms must cover the polychromatic projection data of the scanning object. However, the projection range of a water calibration phantom is limited by the scan field of view (SFOV), thus leading to methodological limitations. A dual-material phantom of a proper size and material can overcome the limitations of a single-material phantom and achieve good correction effects.
format Online
Article
Text
id pubmed-3886221
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-38862212014-01-21 An Investigation of Calibration Phantoms for CT Scanners with Tube Voltage Modulation Zou, Jing Hu, Xiaodong Lv, Hanyu Hu, Xiaotang Int J Biomed Imaging Research Article The effects of calibration phantoms on the correction results of the empirical artifacts correction method (ECCU) for the case of tube modulation were investigated. To improve the validity of the ECCU method, the effect of the geometry parameter of a typical single-material calibration phantom (water calibration phantom) on the ECCU algorithm was investigated. Dual-material calibration phantoms (such as water-bone calibration phantom), geometry arrangement, and the area-ratio of dual-material calibration phantoms were also studied. Preliminary results implied that, to assure the effectiveness of the ECCU algorithm, the polychromatic projections of calibration phantoms must cover the polychromatic projection data of the scanning object. However, the projection range of a water calibration phantom is limited by the scan field of view (SFOV), thus leading to methodological limitations. A dual-material phantom of a proper size and material can overcome the limitations of a single-material phantom and achieve good correction effects. Hindawi Publishing Corporation 2013 2013-12-25 /pmc/articles/PMC3886221/ /pubmed/24454334 http://dx.doi.org/10.1155/2013/563571 Text en Copyright © 2013 Jing Zou et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Zou, Jing
Hu, Xiaodong
Lv, Hanyu
Hu, Xiaotang
An Investigation of Calibration Phantoms for CT Scanners with Tube Voltage Modulation
title An Investigation of Calibration Phantoms for CT Scanners with Tube Voltage Modulation
title_full An Investigation of Calibration Phantoms for CT Scanners with Tube Voltage Modulation
title_fullStr An Investigation of Calibration Phantoms for CT Scanners with Tube Voltage Modulation
title_full_unstemmed An Investigation of Calibration Phantoms for CT Scanners with Tube Voltage Modulation
title_short An Investigation of Calibration Phantoms for CT Scanners with Tube Voltage Modulation
title_sort investigation of calibration phantoms for ct scanners with tube voltage modulation
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3886221/
https://www.ncbi.nlm.nih.gov/pubmed/24454334
http://dx.doi.org/10.1155/2013/563571
work_keys_str_mv AT zoujing aninvestigationofcalibrationphantomsforctscannerswithtubevoltagemodulation
AT huxiaodong aninvestigationofcalibrationphantomsforctscannerswithtubevoltagemodulation
AT lvhanyu aninvestigationofcalibrationphantomsforctscannerswithtubevoltagemodulation
AT huxiaotang aninvestigationofcalibrationphantomsforctscannerswithtubevoltagemodulation
AT zoujing investigationofcalibrationphantomsforctscannerswithtubevoltagemodulation
AT huxiaodong investigationofcalibrationphantomsforctscannerswithtubevoltagemodulation
AT lvhanyu investigationofcalibrationphantomsforctscannerswithtubevoltagemodulation
AT huxiaotang investigationofcalibrationphantomsforctscannerswithtubevoltagemodulation