Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization

NiTi instruments have a high risk of separation due to torsional or flexural fatigue (cyclic fatigue). Chemomechanical preparation, cleaning procedures, chemical disinfection and sterilization cause the corrosion of endodontic instruments that may weaken the fracture resistance of the instruments. O...

Descripción completa

Detalles Bibliográficos
Autores principales: BULEM, Üreyen Kaya, KECECI, Ayse Diljin, GULDAS, Hilmi Egemen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Faculdade de Odontologia de Bauru da Universidade de São Paulo 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3891273/
https://www.ncbi.nlm.nih.gov/pubmed/24473715
http://dx.doi.org/10.1590/1679-775720130083
_version_ 1782299359091621888
author BULEM, Üreyen Kaya
KECECI, Ayse Diljin
GULDAS, Hilmi Egemen
author_facet BULEM, Üreyen Kaya
KECECI, Ayse Diljin
GULDAS, Hilmi Egemen
author_sort BULEM, Üreyen Kaya
collection PubMed
description NiTi instruments have a high risk of separation due to torsional or flexural fatigue (cyclic fatigue). Chemomechanical preparation, cleaning procedures, chemical disinfection and sterilization cause the corrosion of endodontic instruments that may weaken the fracture resistance of the instruments. OBJECTIVE: To assess the effects of NaOCl immersion and autoclave sterilization on the cyclic fatigue resistance of ProFile, FlexMaster, Mtwo and TwistedFiles NiTi instruments (tip size 25, 0.06 taper, n=160). MATERIAL AND METHODS: The instruments (n=10 for each subgroup) were dynamically immersed in NaOCl; immersed in NaOCl and sterilized in one autoclave cycle; 5 cycles immersed in NaOCl and sterilized in autoclave and not immersed in NaOCl and not sterilized (control group). Dynamic cyclic fatigue resistance was tested. The number of cycles to failure (NCF) were statistically analyzed (P<0.05). RESULTS: Kruskall-Wallis test indicated significant differences among the tested instruments in terms of NCF (P=0.000). The mean NCF of Mtwo (556.75) was higher than that of the Twisted File, Flexmaster and ProFile, 483.1, 376.12, 365.25, respectively. NaOCl immersion and autoclave sterilization have no effect on the NCF values of the tested instruments (P>.05). CONCLUSIONS: Cyclic fatigue resistance of the tested NiTi instruments cannot be adversely affected by NaOCl immersion and autoclave sterilization. Production process (TwistedFiles) or design (Twisted Files, FlexMaster, Mtwo and ProFile) of the instruments can influence their cyclic fatigue resistance.
format Online
Article
Text
id pubmed-3891273
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Faculdade de Odontologia de Bauru da Universidade de São Paulo
record_format MEDLINE/PubMed
spelling pubmed-38912732014-01-15 Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization BULEM, Üreyen Kaya KECECI, Ayse Diljin GULDAS, Hilmi Egemen J Appl Oral Sci Original Articles NiTi instruments have a high risk of separation due to torsional or flexural fatigue (cyclic fatigue). Chemomechanical preparation, cleaning procedures, chemical disinfection and sterilization cause the corrosion of endodontic instruments that may weaken the fracture resistance of the instruments. OBJECTIVE: To assess the effects of NaOCl immersion and autoclave sterilization on the cyclic fatigue resistance of ProFile, FlexMaster, Mtwo and TwistedFiles NiTi instruments (tip size 25, 0.06 taper, n=160). MATERIAL AND METHODS: The instruments (n=10 for each subgroup) were dynamically immersed in NaOCl; immersed in NaOCl and sterilized in one autoclave cycle; 5 cycles immersed in NaOCl and sterilized in autoclave and not immersed in NaOCl and not sterilized (control group). Dynamic cyclic fatigue resistance was tested. The number of cycles to failure (NCF) were statistically analyzed (P<0.05). RESULTS: Kruskall-Wallis test indicated significant differences among the tested instruments in terms of NCF (P=0.000). The mean NCF of Mtwo (556.75) was higher than that of the Twisted File, Flexmaster and ProFile, 483.1, 376.12, 365.25, respectively. NaOCl immersion and autoclave sterilization have no effect on the NCF values of the tested instruments (P>.05). CONCLUSIONS: Cyclic fatigue resistance of the tested NiTi instruments cannot be adversely affected by NaOCl immersion and autoclave sterilization. Production process (TwistedFiles) or design (Twisted Files, FlexMaster, Mtwo and ProFile) of the instruments can influence their cyclic fatigue resistance. Faculdade de Odontologia de Bauru da Universidade de São Paulo 2013 /pmc/articles/PMC3891273/ /pubmed/24473715 http://dx.doi.org/10.1590/1679-775720130083 Text en http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Articles
BULEM, Üreyen Kaya
KECECI, Ayse Diljin
GULDAS, Hilmi Egemen
Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization
title Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization
title_full Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization
title_fullStr Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization
title_full_unstemmed Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization
title_short Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization
title_sort experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3891273/
https://www.ncbi.nlm.nih.gov/pubmed/24473715
http://dx.doi.org/10.1590/1679-775720130083
work_keys_str_mv AT bulemureyenkaya experimentalevaluationofcyclicfatigueresistanceoffourdifferentnickeltitaniuminstrumentsafterimmersioninsodiumhypochloriteandorsterilization
AT kececiaysediljin experimentalevaluationofcyclicfatigueresistanceoffourdifferentnickeltitaniuminstrumentsafterimmersioninsodiumhypochloriteandorsterilization
AT guldashilmiegemen experimentalevaluationofcyclicfatigueresistanceoffourdifferentnickeltitaniuminstrumentsafterimmersioninsodiumhypochloriteandorsterilization