Cargando…
The Accuracy of Prostate Cancer Localization Diagnosed on Transrectal Ultrasound-Guided Biopsy Compared to 3-Dimensional Transperineal Approach
Background. Prostate cancer is often understaged following 12-core transrectal ultrasound- (TRUS-) guided biopsies. Our goal is to understand where cancers are typically missed by this method. Methods. Transperineal 3-dimensional mapping biopsy (3DMB) provides a more accurate depiction of disease st...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3891607/ https://www.ncbi.nlm.nih.gov/pubmed/24470798 http://dx.doi.org/10.1155/2013/249080 |
_version_ | 1782299403068899328 |
---|---|
author | Krughoff, Kevin Eid, Khadijah Phillips, Jason Stoimenova, Diliana Smith, Daniel O'Donnell, Colin Crawford, E. David Barqawi, Al |
author_facet | Krughoff, Kevin Eid, Khadijah Phillips, Jason Stoimenova, Diliana Smith, Daniel O'Donnell, Colin Crawford, E. David Barqawi, Al |
author_sort | Krughoff, Kevin |
collection | PubMed |
description | Background. Prostate cancer is often understaged following 12-core transrectal ultrasound- (TRUS-) guided biopsies. Our goal is to understand where cancers are typically missed by this method. Methods. Transperineal 3-dimensional mapping biopsy (3DMB) provides a more accurate depiction of disease status than transrectal ultrasound- (TRUS-) guided biopsy. We compared 3DMB findings in men with prior TRUS-guided biopsies to determine grade and location of missed cancer. Results were evaluated for 161 men with low-risk organ confined prostate cancer. Results. The number of cancer-positive biopsy zones per patient with TRUS was 1.38 ± 1.21 compared to 3.33 ± 4.06 with 3DMB, with most newly discovered cancers originating from the middle lobe and apex. Approximately half of all newly discovered cancerous zones resulted from anterior 3DMB sampling. Gleason upgrade was recognized in 56 patients using 3DMB. When both biopsy methods found positive cores in a given zone, Gleason upgrades occurred most frequently in the middle left and right zones. TRUS cancer-positive zones not confirmed by 3DMB were most often the basal zones. Conclusion. Most cancer upgrades and cancers missed from TRUS biopsy originated in the middle left zone of the prostate, specifically in anterior regions. Anterior sampling may lead to more accurate diagnosis and appropriate followup. |
format | Online Article Text |
id | pubmed-3891607 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-38916072014-01-27 The Accuracy of Prostate Cancer Localization Diagnosed on Transrectal Ultrasound-Guided Biopsy Compared to 3-Dimensional Transperineal Approach Krughoff, Kevin Eid, Khadijah Phillips, Jason Stoimenova, Diliana Smith, Daniel O'Donnell, Colin Crawford, E. David Barqawi, Al Adv Urol Research Article Background. Prostate cancer is often understaged following 12-core transrectal ultrasound- (TRUS-) guided biopsies. Our goal is to understand where cancers are typically missed by this method. Methods. Transperineal 3-dimensional mapping biopsy (3DMB) provides a more accurate depiction of disease status than transrectal ultrasound- (TRUS-) guided biopsy. We compared 3DMB findings in men with prior TRUS-guided biopsies to determine grade and location of missed cancer. Results were evaluated for 161 men with low-risk organ confined prostate cancer. Results. The number of cancer-positive biopsy zones per patient with TRUS was 1.38 ± 1.21 compared to 3.33 ± 4.06 with 3DMB, with most newly discovered cancers originating from the middle lobe and apex. Approximately half of all newly discovered cancerous zones resulted from anterior 3DMB sampling. Gleason upgrade was recognized in 56 patients using 3DMB. When both biopsy methods found positive cores in a given zone, Gleason upgrades occurred most frequently in the middle left and right zones. TRUS cancer-positive zones not confirmed by 3DMB were most often the basal zones. Conclusion. Most cancer upgrades and cancers missed from TRUS biopsy originated in the middle left zone of the prostate, specifically in anterior regions. Anterior sampling may lead to more accurate diagnosis and appropriate followup. Hindawi Publishing Corporation 2013 2013-12-29 /pmc/articles/PMC3891607/ /pubmed/24470798 http://dx.doi.org/10.1155/2013/249080 Text en Copyright © 2013 Kevin Krughoff et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Krughoff, Kevin Eid, Khadijah Phillips, Jason Stoimenova, Diliana Smith, Daniel O'Donnell, Colin Crawford, E. David Barqawi, Al The Accuracy of Prostate Cancer Localization Diagnosed on Transrectal Ultrasound-Guided Biopsy Compared to 3-Dimensional Transperineal Approach |
title | The Accuracy of Prostate Cancer Localization Diagnosed on Transrectal Ultrasound-Guided Biopsy Compared to 3-Dimensional Transperineal Approach |
title_full | The Accuracy of Prostate Cancer Localization Diagnosed on Transrectal Ultrasound-Guided Biopsy Compared to 3-Dimensional Transperineal Approach |
title_fullStr | The Accuracy of Prostate Cancer Localization Diagnosed on Transrectal Ultrasound-Guided Biopsy Compared to 3-Dimensional Transperineal Approach |
title_full_unstemmed | The Accuracy of Prostate Cancer Localization Diagnosed on Transrectal Ultrasound-Guided Biopsy Compared to 3-Dimensional Transperineal Approach |
title_short | The Accuracy of Prostate Cancer Localization Diagnosed on Transrectal Ultrasound-Guided Biopsy Compared to 3-Dimensional Transperineal Approach |
title_sort | accuracy of prostate cancer localization diagnosed on transrectal ultrasound-guided biopsy compared to 3-dimensional transperineal approach |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3891607/ https://www.ncbi.nlm.nih.gov/pubmed/24470798 http://dx.doi.org/10.1155/2013/249080 |
work_keys_str_mv | AT krughoffkevin theaccuracyofprostatecancerlocalizationdiagnosedontransrectalultrasoundguidedbiopsycomparedto3dimensionaltransperinealapproach AT eidkhadijah theaccuracyofprostatecancerlocalizationdiagnosedontransrectalultrasoundguidedbiopsycomparedto3dimensionaltransperinealapproach AT phillipsjason theaccuracyofprostatecancerlocalizationdiagnosedontransrectalultrasoundguidedbiopsycomparedto3dimensionaltransperinealapproach AT stoimenovadiliana theaccuracyofprostatecancerlocalizationdiagnosedontransrectalultrasoundguidedbiopsycomparedto3dimensionaltransperinealapproach AT smithdaniel theaccuracyofprostatecancerlocalizationdiagnosedontransrectalultrasoundguidedbiopsycomparedto3dimensionaltransperinealapproach AT odonnellcolin theaccuracyofprostatecancerlocalizationdiagnosedontransrectalultrasoundguidedbiopsycomparedto3dimensionaltransperinealapproach AT crawfordedavid theaccuracyofprostatecancerlocalizationdiagnosedontransrectalultrasoundguidedbiopsycomparedto3dimensionaltransperinealapproach AT barqawial theaccuracyofprostatecancerlocalizationdiagnosedontransrectalultrasoundguidedbiopsycomparedto3dimensionaltransperinealapproach AT krughoffkevin accuracyofprostatecancerlocalizationdiagnosedontransrectalultrasoundguidedbiopsycomparedto3dimensionaltransperinealapproach AT eidkhadijah accuracyofprostatecancerlocalizationdiagnosedontransrectalultrasoundguidedbiopsycomparedto3dimensionaltransperinealapproach AT phillipsjason accuracyofprostatecancerlocalizationdiagnosedontransrectalultrasoundguidedbiopsycomparedto3dimensionaltransperinealapproach AT stoimenovadiliana accuracyofprostatecancerlocalizationdiagnosedontransrectalultrasoundguidedbiopsycomparedto3dimensionaltransperinealapproach AT smithdaniel accuracyofprostatecancerlocalizationdiagnosedontransrectalultrasoundguidedbiopsycomparedto3dimensionaltransperinealapproach AT odonnellcolin accuracyofprostatecancerlocalizationdiagnosedontransrectalultrasoundguidedbiopsycomparedto3dimensionaltransperinealapproach AT crawfordedavid accuracyofprostatecancerlocalizationdiagnosedontransrectalultrasoundguidedbiopsycomparedto3dimensionaltransperinealapproach AT barqawial accuracyofprostatecancerlocalizationdiagnosedontransrectalultrasoundguidedbiopsycomparedto3dimensionaltransperinealapproach |