Feasibility of deep-inspiration breath-hold PET/CT with short-time acquisition: detectability for pulmonary lesions compared with respiratory-gated PET/CT

OBJECTIVES: Deep-inspiration breath-hold (DIBH) PET/CT with short-time acquisition and respiratory-gated (RG) PET/CT are performed for pulmonary lesions to reduce the respiratory motion artifacts, and to obtain more accurate standardized uptake value (SUV). DIBH PET/CT demonstrates significant advan...

Descripción completa

Detalles Bibliográficos
Autores principales: Yamashita, Shozo, Yokoyama, Kunihiko, Onoguchi, Masahisa, Yamamoto, Haruki, Hiko, Shigeaki, Horita, Akihiro, Nakajima, Kenichi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Japan 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3892105/
https://www.ncbi.nlm.nih.gov/pubmed/24151087
http://dx.doi.org/10.1007/s12149-013-0774-9
_version_ 1782299466562273280
author Yamashita, Shozo
Yokoyama, Kunihiko
Onoguchi, Masahisa
Yamamoto, Haruki
Hiko, Shigeaki
Horita, Akihiro
Nakajima, Kenichi
author_facet Yamashita, Shozo
Yokoyama, Kunihiko
Onoguchi, Masahisa
Yamamoto, Haruki
Hiko, Shigeaki
Horita, Akihiro
Nakajima, Kenichi
author_sort Yamashita, Shozo
collection PubMed
description OBJECTIVES: Deep-inspiration breath-hold (DIBH) PET/CT with short-time acquisition and respiratory-gated (RG) PET/CT are performed for pulmonary lesions to reduce the respiratory motion artifacts, and to obtain more accurate standardized uptake value (SUV). DIBH PET/CT demonstrates significant advantages in terms of rapid examination, good quality of CT images and low radiation exposure. On the other hand, the image quality of DIBH PET is generally inferior to that of RG PET because of short-time acquisition resulting in poor signal-to-noise ratio. In this study, RG PET has been regarded as a gold standard, and its detectability between DIBH and RG PET studies was compared using each of the most optimal reconstruction parameters. METHODS: In the phantom study, the most optimal reconstruction parameters for DIBH and RG PET were determined. In the clinical study, 19 cases were examined using each of the most optimal reconstruction parameters. RESULTS: In the phantom study, the most optimal reconstruction parameters for DIBH and RG PET were different. Reconstruction parameters of DIBH PET could be obtained by reducing the number of subsets for those of RG PET in the state of fixing the number of iterations. In the clinical study, high correlation in the maximum SUV was observed between DIBH and RG PET studies. The clinical result was consistent with that of the phantom study surrounded by air since most of the lesions were located in the low pulmonary radioactivity. CONCLUSION: DIBH PET/CT may be the most practical method which can be the first choice to reduce respiratory motion artifacts if the detectability of DIBH PET is equivalent with that of RG PET. Although DIBH PET may have limitations in suboptimal signal-to-noise ratio, most of the lesions surrounded by low background radioactivity could provide nearly equivalent image quality between DIBH and RG PET studies when each of the most optimal reconstruction parameters was used.
format Online
Article
Text
id pubmed-3892105
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Springer Japan
record_format MEDLINE/PubMed
spelling pubmed-38921052014-01-21 Feasibility of deep-inspiration breath-hold PET/CT with short-time acquisition: detectability for pulmonary lesions compared with respiratory-gated PET/CT Yamashita, Shozo Yokoyama, Kunihiko Onoguchi, Masahisa Yamamoto, Haruki Hiko, Shigeaki Horita, Akihiro Nakajima, Kenichi Ann Nucl Med Original Article OBJECTIVES: Deep-inspiration breath-hold (DIBH) PET/CT with short-time acquisition and respiratory-gated (RG) PET/CT are performed for pulmonary lesions to reduce the respiratory motion artifacts, and to obtain more accurate standardized uptake value (SUV). DIBH PET/CT demonstrates significant advantages in terms of rapid examination, good quality of CT images and low radiation exposure. On the other hand, the image quality of DIBH PET is generally inferior to that of RG PET because of short-time acquisition resulting in poor signal-to-noise ratio. In this study, RG PET has been regarded as a gold standard, and its detectability between DIBH and RG PET studies was compared using each of the most optimal reconstruction parameters. METHODS: In the phantom study, the most optimal reconstruction parameters for DIBH and RG PET were determined. In the clinical study, 19 cases were examined using each of the most optimal reconstruction parameters. RESULTS: In the phantom study, the most optimal reconstruction parameters for DIBH and RG PET were different. Reconstruction parameters of DIBH PET could be obtained by reducing the number of subsets for those of RG PET in the state of fixing the number of iterations. In the clinical study, high correlation in the maximum SUV was observed between DIBH and RG PET studies. The clinical result was consistent with that of the phantom study surrounded by air since most of the lesions were located in the low pulmonary radioactivity. CONCLUSION: DIBH PET/CT may be the most practical method which can be the first choice to reduce respiratory motion artifacts if the detectability of DIBH PET is equivalent with that of RG PET. Although DIBH PET may have limitations in suboptimal signal-to-noise ratio, most of the lesions surrounded by low background radioactivity could provide nearly equivalent image quality between DIBH and RG PET studies when each of the most optimal reconstruction parameters was used. Springer Japan 2013-10-23 2014 /pmc/articles/PMC3892105/ /pubmed/24151087 http://dx.doi.org/10.1007/s12149-013-0774-9 Text en © The Author(s) 2013 https://creativecommons.org/licenses/by/2.0/ Open AccessThis article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Original Article
Yamashita, Shozo
Yokoyama, Kunihiko
Onoguchi, Masahisa
Yamamoto, Haruki
Hiko, Shigeaki
Horita, Akihiro
Nakajima, Kenichi
Feasibility of deep-inspiration breath-hold PET/CT with short-time acquisition: detectability for pulmonary lesions compared with respiratory-gated PET/CT
title Feasibility of deep-inspiration breath-hold PET/CT with short-time acquisition: detectability for pulmonary lesions compared with respiratory-gated PET/CT
title_full Feasibility of deep-inspiration breath-hold PET/CT with short-time acquisition: detectability for pulmonary lesions compared with respiratory-gated PET/CT
title_fullStr Feasibility of deep-inspiration breath-hold PET/CT with short-time acquisition: detectability for pulmonary lesions compared with respiratory-gated PET/CT
title_full_unstemmed Feasibility of deep-inspiration breath-hold PET/CT with short-time acquisition: detectability for pulmonary lesions compared with respiratory-gated PET/CT
title_short Feasibility of deep-inspiration breath-hold PET/CT with short-time acquisition: detectability for pulmonary lesions compared with respiratory-gated PET/CT
title_sort feasibility of deep-inspiration breath-hold pet/ct with short-time acquisition: detectability for pulmonary lesions compared with respiratory-gated pet/ct
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3892105/
https://www.ncbi.nlm.nih.gov/pubmed/24151087
http://dx.doi.org/10.1007/s12149-013-0774-9
work_keys_str_mv AT yamashitashozo feasibilityofdeepinspirationbreathholdpetctwithshorttimeacquisitiondetectabilityforpulmonarylesionscomparedwithrespiratorygatedpetct
AT yokoyamakunihiko feasibilityofdeepinspirationbreathholdpetctwithshorttimeacquisitiondetectabilityforpulmonarylesionscomparedwithrespiratorygatedpetct
AT onoguchimasahisa feasibilityofdeepinspirationbreathholdpetctwithshorttimeacquisitiondetectabilityforpulmonarylesionscomparedwithrespiratorygatedpetct
AT yamamotoharuki feasibilityofdeepinspirationbreathholdpetctwithshorttimeacquisitiondetectabilityforpulmonarylesionscomparedwithrespiratorygatedpetct
AT hikoshigeaki feasibilityofdeepinspirationbreathholdpetctwithshorttimeacquisitiondetectabilityforpulmonarylesionscomparedwithrespiratorygatedpetct
AT horitaakihiro feasibilityofdeepinspirationbreathholdpetctwithshorttimeacquisitiondetectabilityforpulmonarylesionscomparedwithrespiratorygatedpetct
AT nakajimakenichi feasibilityofdeepinspirationbreathholdpetctwithshorttimeacquisitiondetectabilityforpulmonarylesionscomparedwithrespiratorygatedpetct