Cargando…

Platform switching on wide-diameter external hex implants: a finite element analysis

Objectives: The objective of this work was to use finite element analysis to compare the effect of forces coming to bear on abutments 4.1 or 5.0 mm in diameter connected to a 5.0 mm implant (i.e. with or without platform switching). Study design: A 3D CAD model of a 5 x 11.5 mm external hex implant...

Descripción completa

Detalles Bibliográficos
Autores principales: Sivolella, Stefano, Guazzo, Riccardo, Bressan, Eriberto, Berengo, Mario, Stellini, Edoardo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medicina Oral S.L. 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3892223/
https://www.ncbi.nlm.nih.gov/pubmed/24455061
http://dx.doi.org/10.4317/jced.50991
_version_ 1782299488948322304
author Sivolella, Stefano
Guazzo, Riccardo
Bressan, Eriberto
Berengo, Mario
Stellini, Edoardo
author_facet Sivolella, Stefano
Guazzo, Riccardo
Bressan, Eriberto
Berengo, Mario
Stellini, Edoardo
author_sort Sivolella, Stefano
collection PubMed
description Objectives: The objective of this work was to use finite element analysis to compare the effect of forces coming to bear on abutments 4.1 or 5.0 mm in diameter connected to a 5.0 mm implant (i.e. with or without platform switching). Study design: A 3D CAD model of a 5 x 11.5 mm external hex implant was developed, complete with a connection screw and either of two abutments, one 4.1 and the other 5 mm in diameter, to assess the influence of two loading conditions, i.e. 200 N loaded either axially or off center on the top of the abutment. Results and conclusions: In the symmetrically loaded models, greater stresses were transmitted to the bone in the area below the neck of the implant in the case of the wider-diameter abutment. When the narrower abutment was considered, the stress lines remained confined to the metal and were transferred to the bone in a more distal position. When the stresses in the bone where compared under non-symmetrical loading of the larger- and smaller-diameter abutments, the stresses reached lower values in the latter case. These findings indicate that platform switching (i.e. coupling a 4.1 mm abutment with a 5 mm implant) achieves a better, more even distribution of the peri-implant stresses deriving from simulated occlusal loads on the bone margins. Key words:Platform switching, finite element analysis, implant.
format Online
Article
Text
id pubmed-3892223
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Medicina Oral S.L.
record_format MEDLINE/PubMed
spelling pubmed-38922232014-01-22 Platform switching on wide-diameter external hex implants: a finite element analysis Sivolella, Stefano Guazzo, Riccardo Bressan, Eriberto Berengo, Mario Stellini, Edoardo J Clin Exp Dent Research Objectives: The objective of this work was to use finite element analysis to compare the effect of forces coming to bear on abutments 4.1 or 5.0 mm in diameter connected to a 5.0 mm implant (i.e. with or without platform switching). Study design: A 3D CAD model of a 5 x 11.5 mm external hex implant was developed, complete with a connection screw and either of two abutments, one 4.1 and the other 5 mm in diameter, to assess the influence of two loading conditions, i.e. 200 N loaded either axially or off center on the top of the abutment. Results and conclusions: In the symmetrically loaded models, greater stresses were transmitted to the bone in the area below the neck of the implant in the case of the wider-diameter abutment. When the narrower abutment was considered, the stress lines remained confined to the metal and were transferred to the bone in a more distal position. When the stresses in the bone where compared under non-symmetrical loading of the larger- and smaller-diameter abutments, the stresses reached lower values in the latter case. These findings indicate that platform switching (i.e. coupling a 4.1 mm abutment with a 5 mm implant) achieves a better, more even distribution of the peri-implant stresses deriving from simulated occlusal loads on the bone margins. Key words:Platform switching, finite element analysis, implant. Medicina Oral S.L. 2013-04-01 /pmc/articles/PMC3892223/ /pubmed/24455061 http://dx.doi.org/10.4317/jced.50991 Text en Copyright: © 2013 Medicina Oral S.L. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Sivolella, Stefano
Guazzo, Riccardo
Bressan, Eriberto
Berengo, Mario
Stellini, Edoardo
Platform switching on wide-diameter external hex implants: a finite element analysis
title Platform switching on wide-diameter external hex implants: a finite element analysis
title_full Platform switching on wide-diameter external hex implants: a finite element analysis
title_fullStr Platform switching on wide-diameter external hex implants: a finite element analysis
title_full_unstemmed Platform switching on wide-diameter external hex implants: a finite element analysis
title_short Platform switching on wide-diameter external hex implants: a finite element analysis
title_sort platform switching on wide-diameter external hex implants: a finite element analysis
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3892223/
https://www.ncbi.nlm.nih.gov/pubmed/24455061
http://dx.doi.org/10.4317/jced.50991
work_keys_str_mv AT sivolellastefano platformswitchingonwidediameterexternalheximplantsafiniteelementanalysis
AT guazzoriccardo platformswitchingonwidediameterexternalheximplantsafiniteelementanalysis
AT bressaneriberto platformswitchingonwidediameterexternalheximplantsafiniteelementanalysis
AT berengomario platformswitchingonwidediameterexternalheximplantsafiniteelementanalysis
AT stelliniedoardo platformswitchingonwidediameterexternalheximplantsafiniteelementanalysis