Cargando…
Platform switching on wide-diameter external hex implants: a finite element analysis
Objectives: The objective of this work was to use finite element analysis to compare the effect of forces coming to bear on abutments 4.1 or 5.0 mm in diameter connected to a 5.0 mm implant (i.e. with or without platform switching). Study design: A 3D CAD model of a 5 x 11.5 mm external hex implant...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medicina Oral S.L.
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3892223/ https://www.ncbi.nlm.nih.gov/pubmed/24455061 http://dx.doi.org/10.4317/jced.50991 |
_version_ | 1782299488948322304 |
---|---|
author | Sivolella, Stefano Guazzo, Riccardo Bressan, Eriberto Berengo, Mario Stellini, Edoardo |
author_facet | Sivolella, Stefano Guazzo, Riccardo Bressan, Eriberto Berengo, Mario Stellini, Edoardo |
author_sort | Sivolella, Stefano |
collection | PubMed |
description | Objectives: The objective of this work was to use finite element analysis to compare the effect of forces coming to bear on abutments 4.1 or 5.0 mm in diameter connected to a 5.0 mm implant (i.e. with or without platform switching). Study design: A 3D CAD model of a 5 x 11.5 mm external hex implant was developed, complete with a connection screw and either of two abutments, one 4.1 and the other 5 mm in diameter, to assess the influence of two loading conditions, i.e. 200 N loaded either axially or off center on the top of the abutment. Results and conclusions: In the symmetrically loaded models, greater stresses were transmitted to the bone in the area below the neck of the implant in the case of the wider-diameter abutment. When the narrower abutment was considered, the stress lines remained confined to the metal and were transferred to the bone in a more distal position. When the stresses in the bone where compared under non-symmetrical loading of the larger- and smaller-diameter abutments, the stresses reached lower values in the latter case. These findings indicate that platform switching (i.e. coupling a 4.1 mm abutment with a 5 mm implant) achieves a better, more even distribution of the peri-implant stresses deriving from simulated occlusal loads on the bone margins. Key words:Platform switching, finite element analysis, implant. |
format | Online Article Text |
id | pubmed-3892223 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Medicina Oral S.L. |
record_format | MEDLINE/PubMed |
spelling | pubmed-38922232014-01-22 Platform switching on wide-diameter external hex implants: a finite element analysis Sivolella, Stefano Guazzo, Riccardo Bressan, Eriberto Berengo, Mario Stellini, Edoardo J Clin Exp Dent Research Objectives: The objective of this work was to use finite element analysis to compare the effect of forces coming to bear on abutments 4.1 or 5.0 mm in diameter connected to a 5.0 mm implant (i.e. with or without platform switching). Study design: A 3D CAD model of a 5 x 11.5 mm external hex implant was developed, complete with a connection screw and either of two abutments, one 4.1 and the other 5 mm in diameter, to assess the influence of two loading conditions, i.e. 200 N loaded either axially or off center on the top of the abutment. Results and conclusions: In the symmetrically loaded models, greater stresses were transmitted to the bone in the area below the neck of the implant in the case of the wider-diameter abutment. When the narrower abutment was considered, the stress lines remained confined to the metal and were transferred to the bone in a more distal position. When the stresses in the bone where compared under non-symmetrical loading of the larger- and smaller-diameter abutments, the stresses reached lower values in the latter case. These findings indicate that platform switching (i.e. coupling a 4.1 mm abutment with a 5 mm implant) achieves a better, more even distribution of the peri-implant stresses deriving from simulated occlusal loads on the bone margins. Key words:Platform switching, finite element analysis, implant. Medicina Oral S.L. 2013-04-01 /pmc/articles/PMC3892223/ /pubmed/24455061 http://dx.doi.org/10.4317/jced.50991 Text en Copyright: © 2013 Medicina Oral S.L. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Sivolella, Stefano Guazzo, Riccardo Bressan, Eriberto Berengo, Mario Stellini, Edoardo Platform switching on wide-diameter external hex implants: a finite element analysis |
title | Platform switching on wide-diameter external hex implants:
a finite element analysis |
title_full | Platform switching on wide-diameter external hex implants:
a finite element analysis |
title_fullStr | Platform switching on wide-diameter external hex implants:
a finite element analysis |
title_full_unstemmed | Platform switching on wide-diameter external hex implants:
a finite element analysis |
title_short | Platform switching on wide-diameter external hex implants:
a finite element analysis |
title_sort | platform switching on wide-diameter external hex implants:
a finite element analysis |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3892223/ https://www.ncbi.nlm.nih.gov/pubmed/24455061 http://dx.doi.org/10.4317/jced.50991 |
work_keys_str_mv | AT sivolellastefano platformswitchingonwidediameterexternalheximplantsafiniteelementanalysis AT guazzoriccardo platformswitchingonwidediameterexternalheximplantsafiniteelementanalysis AT bressaneriberto platformswitchingonwidediameterexternalheximplantsafiniteelementanalysis AT berengomario platformswitchingonwidediameterexternalheximplantsafiniteelementanalysis AT stelliniedoardo platformswitchingonwidediameterexternalheximplantsafiniteelementanalysis |