Cargando…
How accurate is image guided radiation therapy (IGRT) delivered with a micro-irradiator?
There is significant interest in delivering precisely targeted small-volume radiation treatments, in the pre-clinical setting, to study dose-volume relationships with tumor control and normal tissue damage. In this work we investigate the IGRT targeting accuracy of the XRad225Cx system from Precisio...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3894105/ https://www.ncbi.nlm.nih.gov/pubmed/24454521 http://dx.doi.org/10.1088/1742-6596/444/1/012070 |
_version_ | 1782299801624248320 |
---|---|
author | Oldham, M Newton, J Rankine, L Adamovics, J Kirsch, D Das, S |
author_facet | Oldham, M Newton, J Rankine, L Adamovics, J Kirsch, D Das, S |
author_sort | Oldham, M |
collection | PubMed |
description | There is significant interest in delivering precisely targeted small-volume radiation treatments, in the pre-clinical setting, to study dose-volume relationships with tumor control and normal tissue damage. In this work we investigate the IGRT targeting accuracy of the XRad225Cx system from Precision x-Ray using high resolution 3D dosimetry techniques. Initial results revealed a significant targeting error of about 2.4mm. This error was reduced to within 0.5mm after the IGRT hardware and software had been recalibrated. The facility for 3D dosimetry was essential to gain a comprehensive understanding of the targeting error in 3D. |
format | Online Article Text |
id | pubmed-3894105 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
record_format | MEDLINE/PubMed |
spelling | pubmed-38941052014-01-16 How accurate is image guided radiation therapy (IGRT) delivered with a micro-irradiator? Oldham, M Newton, J Rankine, L Adamovics, J Kirsch, D Das, S J Phys Conf Ser Article There is significant interest in delivering precisely targeted small-volume radiation treatments, in the pre-clinical setting, to study dose-volume relationships with tumor control and normal tissue damage. In this work we investigate the IGRT targeting accuracy of the XRad225Cx system from Precision x-Ray using high resolution 3D dosimetry techniques. Initial results revealed a significant targeting error of about 2.4mm. This error was reduced to within 0.5mm after the IGRT hardware and software had been recalibrated. The facility for 3D dosimetry was essential to gain a comprehensive understanding of the targeting error in 3D. 2013 /pmc/articles/PMC3894105/ /pubmed/24454521 http://dx.doi.org/10.1088/1742-6596/444/1/012070 Text en http://creativecommons.org/licenses/by/3.0/ Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by IOP Publishing Ltd |
spellingShingle | Article Oldham, M Newton, J Rankine, L Adamovics, J Kirsch, D Das, S How accurate is image guided radiation therapy (IGRT) delivered with a micro-irradiator? |
title | How accurate is image guided radiation therapy (IGRT) delivered with a micro-irradiator? |
title_full | How accurate is image guided radiation therapy (IGRT) delivered with a micro-irradiator? |
title_fullStr | How accurate is image guided radiation therapy (IGRT) delivered with a micro-irradiator? |
title_full_unstemmed | How accurate is image guided radiation therapy (IGRT) delivered with a micro-irradiator? |
title_short | How accurate is image guided radiation therapy (IGRT) delivered with a micro-irradiator? |
title_sort | how accurate is image guided radiation therapy (igrt) delivered with a micro-irradiator? |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3894105/ https://www.ncbi.nlm.nih.gov/pubmed/24454521 http://dx.doi.org/10.1088/1742-6596/444/1/012070 |
work_keys_str_mv | AT oldhamm howaccurateisimageguidedradiationtherapyigrtdeliveredwithamicroirradiator AT newtonj howaccurateisimageguidedradiationtherapyigrtdeliveredwithamicroirradiator AT rankinel howaccurateisimageguidedradiationtherapyigrtdeliveredwithamicroirradiator AT adamovicsj howaccurateisimageguidedradiationtherapyigrtdeliveredwithamicroirradiator AT kirschd howaccurateisimageguidedradiationtherapyigrtdeliveredwithamicroirradiator AT dass howaccurateisimageguidedradiationtherapyigrtdeliveredwithamicroirradiator |