Cargando…
Constitution-specific features of perspiration and skin visco-elasticity in SCM
BACKGROUND: Human skin properties have been used as an important diagnostic component in traditional medicine as they change with health conditions. Sasang constitutional medicine (SCM) puts emphasis on the recognition of the constitution-specific skin features prior to the diagnostic decision of he...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3897972/ https://www.ncbi.nlm.nih.gov/pubmed/24422750 http://dx.doi.org/10.1186/1472-6882-14-24 |
_version_ | 1782300333630816256 |
---|---|
author | Kim, Young-Min Ku, Boncho Jung, Chang Jin Kim, Jaeuk U Jeon, Young Ju Kim, Keun Ho Kim, Jong Yeol |
author_facet | Kim, Young-Min Ku, Boncho Jung, Chang Jin Kim, Jaeuk U Jeon, Young Ju Kim, Keun Ho Kim, Jong Yeol |
author_sort | Kim, Young-Min |
collection | PubMed |
description | BACKGROUND: Human skin properties have been used as an important diagnostic component in traditional medicine as they change with health conditions. Sasang constitutional medicine (SCM) puts emphasis on the recognition of the constitution-specific skin features prior to the diagnostic decision of health. In this work, in search of skin-characteristics effectively reflecting SCM features, we compared several skin properties such as perspiration, visco-elasticity, elasticity, and elasticity hysteresis, in several candidate body parts. METHODS: We conducted a clinical study in which a total of 111 healthy females aged 50 – 70 years participated with their Sasang constitution (SC) types determined objectively by the Sasang constitutional analytic tool. Perspiration on the skin surface was estimated by using a capacitance sensor to measure the amount of moisture on the palm, forehead, and philtrum before and after a heating stimulus. We acquired the visco-elasticity, elasticity, and elasticity hysteresis at the forearm by Dermalab’s elasticity sensing device. An analysis of covariance (ANCOVA) was conducted to evaluate the effect of SC on the nine skin features acquired. RESULTS: The visco-elasticity of the forearm of the Soeum-in (SE) group was significantly lower than that of the Taeeum-in (TE) group (F = 68.867, p < 0.001), whereas the elasticity hysteresis of the SE group was higher than that of the TE group (F = 10.364, p < 0.01). The TE group had more perspiration on the forehead than the SE group (F = 9.050, p < 0.01). The SE group had a large perspiration difference between the philtrum and the forehead compared with the TE group (F = 7.892, p < 0.01). CONCLUSIONS: We found four significant skin features that reflect the inherent constitutional attributes of the TE and SE groups in accordance with SCM literature; the visco-elasticity, elasticity hysteresis, perspiration on the forehead and philtrum. Our findings are based on a novel interpretation of the SCM literature and will contribute to developing the constitutional health status evaluation system in SCM. |
format | Online Article Text |
id | pubmed-3897972 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-38979722014-02-05 Constitution-specific features of perspiration and skin visco-elasticity in SCM Kim, Young-Min Ku, Boncho Jung, Chang Jin Kim, Jaeuk U Jeon, Young Ju Kim, Keun Ho Kim, Jong Yeol BMC Complement Altern Med Research Article BACKGROUND: Human skin properties have been used as an important diagnostic component in traditional medicine as they change with health conditions. Sasang constitutional medicine (SCM) puts emphasis on the recognition of the constitution-specific skin features prior to the diagnostic decision of health. In this work, in search of skin-characteristics effectively reflecting SCM features, we compared several skin properties such as perspiration, visco-elasticity, elasticity, and elasticity hysteresis, in several candidate body parts. METHODS: We conducted a clinical study in which a total of 111 healthy females aged 50 – 70 years participated with their Sasang constitution (SC) types determined objectively by the Sasang constitutional analytic tool. Perspiration on the skin surface was estimated by using a capacitance sensor to measure the amount of moisture on the palm, forehead, and philtrum before and after a heating stimulus. We acquired the visco-elasticity, elasticity, and elasticity hysteresis at the forearm by Dermalab’s elasticity sensing device. An analysis of covariance (ANCOVA) was conducted to evaluate the effect of SC on the nine skin features acquired. RESULTS: The visco-elasticity of the forearm of the Soeum-in (SE) group was significantly lower than that of the Taeeum-in (TE) group (F = 68.867, p < 0.001), whereas the elasticity hysteresis of the SE group was higher than that of the TE group (F = 10.364, p < 0.01). The TE group had more perspiration on the forehead than the SE group (F = 9.050, p < 0.01). The SE group had a large perspiration difference between the philtrum and the forehead compared with the TE group (F = 7.892, p < 0.01). CONCLUSIONS: We found four significant skin features that reflect the inherent constitutional attributes of the TE and SE groups in accordance with SCM literature; the visco-elasticity, elasticity hysteresis, perspiration on the forehead and philtrum. Our findings are based on a novel interpretation of the SCM literature and will contribute to developing the constitutional health status evaluation system in SCM. BioMed Central 2014-01-15 /pmc/articles/PMC3897972/ /pubmed/24422750 http://dx.doi.org/10.1186/1472-6882-14-24 Text en Copyright © 2014 Kim et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Kim, Young-Min Ku, Boncho Jung, Chang Jin Kim, Jaeuk U Jeon, Young Ju Kim, Keun Ho Kim, Jong Yeol Constitution-specific features of perspiration and skin visco-elasticity in SCM |
title | Constitution-specific features of perspiration and skin visco-elasticity in SCM |
title_full | Constitution-specific features of perspiration and skin visco-elasticity in SCM |
title_fullStr | Constitution-specific features of perspiration and skin visco-elasticity in SCM |
title_full_unstemmed | Constitution-specific features of perspiration and skin visco-elasticity in SCM |
title_short | Constitution-specific features of perspiration and skin visco-elasticity in SCM |
title_sort | constitution-specific features of perspiration and skin visco-elasticity in scm |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3897972/ https://www.ncbi.nlm.nih.gov/pubmed/24422750 http://dx.doi.org/10.1186/1472-6882-14-24 |
work_keys_str_mv | AT kimyoungmin constitutionspecificfeaturesofperspirationandskinviscoelasticityinscm AT kuboncho constitutionspecificfeaturesofperspirationandskinviscoelasticityinscm AT jungchangjin constitutionspecificfeaturesofperspirationandskinviscoelasticityinscm AT kimjaeuku constitutionspecificfeaturesofperspirationandskinviscoelasticityinscm AT jeonyoungju constitutionspecificfeaturesofperspirationandskinviscoelasticityinscm AT kimkeunho constitutionspecificfeaturesofperspirationandskinviscoelasticityinscm AT kimjongyeol constitutionspecificfeaturesofperspirationandskinviscoelasticityinscm |