A theoretical framework for quantifying blood volume flow rate from dynamic angiographic data and application to vessel-encoded arterial spin labeling MRI()

Angiographic methods can provide valuable information on vessel morphology and hemodynamics, but are often qualitative in nature, somewhat limiting their ability for comparison across arteries and subjects. In this work we present a method for quantifying absolute blood volume flow rates within larg...

Descripción completa

Detalles Bibliográficos
Autores principales: Okell, Thomas W., Chappell, Michael A., Jezzard, Peter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3898265/
https://www.ncbi.nlm.nih.gov/pubmed/23871963
http://dx.doi.org/10.1016/j.media.2013.06.005
_version_ 1782300394560421888
author Okell, Thomas W.
Chappell, Michael A.
Jezzard, Peter
author_facet Okell, Thomas W.
Chappell, Michael A.
Jezzard, Peter
author_sort Okell, Thomas W.
collection PubMed
description Angiographic methods can provide valuable information on vessel morphology and hemodynamics, but are often qualitative in nature, somewhat limiting their ability for comparison across arteries and subjects. In this work we present a method for quantifying absolute blood volume flow rates within large vessels using dynamic angiographic data. First, a kinetic model incorporating relative blood volume, bolus dispersion and signal attenuation is fitted to the data. A self-calibration method is also described for both 2D and 3D data sets to convert the relative blood volume parameter into absolute units. The parameter values are then used to simulate the signal arising from a very short bolus, in the absence of signal attenuation, which can be readily encompassed within a vessel mask of interest. The volume flow rate can then be determined by calculating the resultant blood volume within the vessel mask divided by the simulated bolus duration. This method is applied to non-contrast magnetic resonance imaging data from a flow phantom and also to the cerebral arteries of healthy volunteers acquired using a 2D vessel-encoded pseudocontinuous arterial spin labeling pulse sequence. This allows the quantitative flow contribution in downstream vessels to be determined from each major brain-feeding artery. Excellent agreement was found between the actual and estimated flow rates in the phantom, particularly below 4.5 ml/s, typical of the cerebral vasculature. Flow rates measured in healthy volunteers were generally consistent with values found in the literature. This method is likely to be of use in patients with a variety of cerebrovascular diseases, such as the assessment of collateral flow in patients with steno-occlusive disease or the evaluation of arteriovenous malformations.
format Online
Article
Text
id pubmed-3898265
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-38982652014-01-24 A theoretical framework for quantifying blood volume flow rate from dynamic angiographic data and application to vessel-encoded arterial spin labeling MRI() Okell, Thomas W. Chappell, Michael A. Jezzard, Peter Med Image Anal Article Angiographic methods can provide valuable information on vessel morphology and hemodynamics, but are often qualitative in nature, somewhat limiting their ability for comparison across arteries and subjects. In this work we present a method for quantifying absolute blood volume flow rates within large vessels using dynamic angiographic data. First, a kinetic model incorporating relative blood volume, bolus dispersion and signal attenuation is fitted to the data. A self-calibration method is also described for both 2D and 3D data sets to convert the relative blood volume parameter into absolute units. The parameter values are then used to simulate the signal arising from a very short bolus, in the absence of signal attenuation, which can be readily encompassed within a vessel mask of interest. The volume flow rate can then be determined by calculating the resultant blood volume within the vessel mask divided by the simulated bolus duration. This method is applied to non-contrast magnetic resonance imaging data from a flow phantom and also to the cerebral arteries of healthy volunteers acquired using a 2D vessel-encoded pseudocontinuous arterial spin labeling pulse sequence. This allows the quantitative flow contribution in downstream vessels to be determined from each major brain-feeding artery. Excellent agreement was found between the actual and estimated flow rates in the phantom, particularly below 4.5 ml/s, typical of the cerebral vasculature. Flow rates measured in healthy volunteers were generally consistent with values found in the literature. This method is likely to be of use in patients with a variety of cerebrovascular diseases, such as the assessment of collateral flow in patients with steno-occlusive disease or the evaluation of arteriovenous malformations. Elsevier 2013-12 /pmc/articles/PMC3898265/ /pubmed/23871963 http://dx.doi.org/10.1016/j.media.2013.06.005 Text en © 2013 The Authors https://creativecommons.org/licenses/by/3.0/ Open Access under CC BY 3.0 (https://creativecommons.org/licenses/by/3.0/) license
spellingShingle Article
Okell, Thomas W.
Chappell, Michael A.
Jezzard, Peter
A theoretical framework for quantifying blood volume flow rate from dynamic angiographic data and application to vessel-encoded arterial spin labeling MRI()
title A theoretical framework for quantifying blood volume flow rate from dynamic angiographic data and application to vessel-encoded arterial spin labeling MRI()
title_full A theoretical framework for quantifying blood volume flow rate from dynamic angiographic data and application to vessel-encoded arterial spin labeling MRI()
title_fullStr A theoretical framework for quantifying blood volume flow rate from dynamic angiographic data and application to vessel-encoded arterial spin labeling MRI()
title_full_unstemmed A theoretical framework for quantifying blood volume flow rate from dynamic angiographic data and application to vessel-encoded arterial spin labeling MRI()
title_short A theoretical framework for quantifying blood volume flow rate from dynamic angiographic data and application to vessel-encoded arterial spin labeling MRI()
title_sort theoretical framework for quantifying blood volume flow rate from dynamic angiographic data and application to vessel-encoded arterial spin labeling mri()
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3898265/
https://www.ncbi.nlm.nih.gov/pubmed/23871963
http://dx.doi.org/10.1016/j.media.2013.06.005
work_keys_str_mv AT okellthomasw atheoreticalframeworkforquantifyingbloodvolumeflowratefromdynamicangiographicdataandapplicationtovesselencodedarterialspinlabelingmri
AT chappellmichaela atheoreticalframeworkforquantifyingbloodvolumeflowratefromdynamicangiographicdataandapplicationtovesselencodedarterialspinlabelingmri
AT jezzardpeter atheoreticalframeworkforquantifyingbloodvolumeflowratefromdynamicangiographicdataandapplicationtovesselencodedarterialspinlabelingmri
AT okellthomasw theoreticalframeworkforquantifyingbloodvolumeflowratefromdynamicangiographicdataandapplicationtovesselencodedarterialspinlabelingmri
AT chappellmichaela theoreticalframeworkforquantifyingbloodvolumeflowratefromdynamicangiographicdataandapplicationtovesselencodedarterialspinlabelingmri
AT jezzardpeter theoreticalframeworkforquantifyingbloodvolumeflowratefromdynamicangiographicdataandapplicationtovesselencodedarterialspinlabelingmri